Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties

Derek P Lindsey,1 Luis Perez-Orribo,2 Nestor Rodriguez-Martinez,2 Phillip M Reyes,2 Anna Newcomb,2 Alexandria Cable,2 Grace Hickam,2 Scott A Yerby,1 Neil R Crawford21SI-BONE, Inc., San Jose, CA, USA; 2Spinal Biomechanics Research Laboratory, Barrow Neurological Institute, St Joseph's Hospit...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Lindsey DP, Perez-Orribo L, Rodriguez-Martinez N, Reyes PM, Newcomb A, Cable A, Hickam G, Yerby SA, Crawford NR
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://doaj.org/article/1e8aa68f6b4746a19d935cfd16dc479f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1e8aa68f6b4746a19d935cfd16dc479f
record_format dspace
spelling oai:doaj.org-article:1e8aa68f6b4746a19d935cfd16dc479f2021-12-02T00:32:04ZEvaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties1179-1470https://doaj.org/article/1e8aa68f6b4746a19d935cfd16dc479f2014-05-01T00:00:00Zhttp://www.dovepress.com/evaluation-of-a-minimally-invasive-procedure-for-sacroiliac-joint-fusi-a16850https://doaj.org/toc/1179-1470 Derek P Lindsey,1 Luis Perez-Orribo,2 Nestor Rodriguez-Martinez,2 Phillip M Reyes,2 Anna Newcomb,2 Alexandria Cable,2 Grace Hickam,2 Scott A Yerby,1 Neil R Crawford21SI-BONE, Inc., San Jose, CA, USA; 2Spinal Biomechanics Research Laboratory, Barrow Neurological Institute, St Joseph's Hospital and Medical Center, Phoenix, AZ, USAIntroduction: Sacroiliac (SI) joint pain has become a recognized factor in low back pain. The purpose of this study was to investigate the effect of a minimally invasive surgical SI joint fusion procedure on the in vitro biomechanics of the SI joint before and after cyclic loading.Methods: Seven cadaveric specimens were tested under the following conditions: intact, posterior ligaments (PL) and pubic symphysis (PS) cut, treated (three implants placed), and after 5,000 cycles of flexion–extension. The range of motion (ROM) in flexion–extension, lateral bending, and axial rotation was determined with an applied 7.5 N • m moment using an optoelectronic system. Results for each ROM were compared using a repeated measures analysis of variance (ANOVA) with a Holm–Šidák post-hoc test.Results: Placement of three fusion devices decreased the flexion–extension ROM. Lateral bending and axial rotation were not significantly altered. All PL/PS cut and post-cyclic ROMs were larger than in the intact condition. The 5,000 cycles of flexion–extension did not lead to a significant increase in any ROMs.Discussion: In the current model, placement of three 7.0 mm iFuse Implants significantly decreased the flexion–extension ROM. Joint ROM was not increased by 5,000 flexion–extension cycles.Keywords: biomechanics, iliosacral, arthrodesis, cadaverLindsey DPPerez-Orribo LRodriguez-Martinez NReyes PMNewcomb ACable AHickam GYerby SACrawford NRDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2014, Iss default, Pp 131-137 (2014)
institution DOAJ
collection DOAJ
language EN
topic Medical technology
R855-855.5
spellingShingle Medical technology
R855-855.5
Lindsey DP
Perez-Orribo L
Rodriguez-Martinez N
Reyes PM
Newcomb A
Cable A
Hickam G
Yerby SA
Crawford NR
Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
description Derek P Lindsey,1 Luis Perez-Orribo,2 Nestor Rodriguez-Martinez,2 Phillip M Reyes,2 Anna Newcomb,2 Alexandria Cable,2 Grace Hickam,2 Scott A Yerby,1 Neil R Crawford21SI-BONE, Inc., San Jose, CA, USA; 2Spinal Biomechanics Research Laboratory, Barrow Neurological Institute, St Joseph's Hospital and Medical Center, Phoenix, AZ, USAIntroduction: Sacroiliac (SI) joint pain has become a recognized factor in low back pain. The purpose of this study was to investigate the effect of a minimally invasive surgical SI joint fusion procedure on the in vitro biomechanics of the SI joint before and after cyclic loading.Methods: Seven cadaveric specimens were tested under the following conditions: intact, posterior ligaments (PL) and pubic symphysis (PS) cut, treated (three implants placed), and after 5,000 cycles of flexion–extension. The range of motion (ROM) in flexion–extension, lateral bending, and axial rotation was determined with an applied 7.5 N • m moment using an optoelectronic system. Results for each ROM were compared using a repeated measures analysis of variance (ANOVA) with a Holm–Šidák post-hoc test.Results: Placement of three fusion devices decreased the flexion–extension ROM. Lateral bending and axial rotation were not significantly altered. All PL/PS cut and post-cyclic ROMs were larger than in the intact condition. The 5,000 cycles of flexion–extension did not lead to a significant increase in any ROMs.Discussion: In the current model, placement of three 7.0 mm iFuse Implants significantly decreased the flexion–extension ROM. Joint ROM was not increased by 5,000 flexion–extension cycles.Keywords: biomechanics, iliosacral, arthrodesis, cadaver
format article
author Lindsey DP
Perez-Orribo L
Rodriguez-Martinez N
Reyes PM
Newcomb A
Cable A
Hickam G
Yerby SA
Crawford NR
author_facet Lindsey DP
Perez-Orribo L
Rodriguez-Martinez N
Reyes PM
Newcomb A
Cable A
Hickam G
Yerby SA
Crawford NR
author_sort Lindsey DP
title Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
title_short Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
title_full Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
title_fullStr Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
title_full_unstemmed Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
title_sort evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties
publisher Dove Medical Press
publishDate 2014
url https://doaj.org/article/1e8aa68f6b4746a19d935cfd16dc479f
work_keys_str_mv AT lindseydp evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT perezorribol evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT rodriguezmartinezn evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT reyespm evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT newcomba evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT cablea evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT hickamg evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT yerbysa evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
AT crawfordnr evaluationofaminimallyinvasiveprocedureforsacroiliacjointfusionndashaninvitrobiomechanicalanalysisofinitialandcycledproperties
_version_ 1718403662199390208