Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface

In this study, convective heat transfer phenomena were investigated by means of a Guarded Hot Box (GHB) apparatus. An experimental setup characterized by air and surface temperature probes, and a hot-wire anemometer was used. Five small fans were installed in the metering chamber to generate a force...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: de Rubeis Tullio, Evangelisti Luca, Guattari Claudia, De Lieto Vollaro Roberto, Asdrubali Francesco, Ambrosini Dario, Paoletti Domenica
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/1f0bd0bc09cf4f7c96e7454d62097bef
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1f0bd0bc09cf4f7c96e7454d62097bef
record_format dspace
spelling oai:doaj.org-article:1f0bd0bc09cf4f7c96e7454d62097bef2021-11-08T15:18:51ZInfluence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface2267-124210.1051/e3sconf/202131202012https://doaj.org/article/1f0bd0bc09cf4f7c96e7454d62097bef2021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/88/e3sconf_ati2021_02012.pdfhttps://doaj.org/toc/2267-1242In this study, convective heat transfer phenomena were investigated by means of a Guarded Hot Box (GHB) apparatus. An experimental setup characterized by air and surface temperature probes, and a hot-wire anemometer was used. Five small fans were installed in the metering chamber to generate a forced air flow characterized by different velocity values. So, the GHB was used for investigating the influence of different air speed values on internal convective coefficients. Considering horizontal heat fluxes, an internal convective coefficient values of 2.5 W/m2K is reported in the Standard ISO 6946. However, no exhaustive description about this value is provided. The aim of this work is to experimentally determine the internal thermal surface resistance, quantifying how the convective heat transfer coefficient varies as air velocity changes.de Rubeis TullioEvangelisti LucaGuattari ClaudiaDe Lieto Vollaro RobertoAsdrubali FrancescoAmbrosini DarioPaoletti DomenicaEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 312, p 02012 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Environmental sciences
GE1-350
spellingShingle Environmental sciences
GE1-350
de Rubeis Tullio
Evangelisti Luca
Guattari Claudia
De Lieto Vollaro Roberto
Asdrubali Francesco
Ambrosini Dario
Paoletti Domenica
Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
description In this study, convective heat transfer phenomena were investigated by means of a Guarded Hot Box (GHB) apparatus. An experimental setup characterized by air and surface temperature probes, and a hot-wire anemometer was used. Five small fans were installed in the metering chamber to generate a forced air flow characterized by different velocity values. So, the GHB was used for investigating the influence of different air speed values on internal convective coefficients. Considering horizontal heat fluxes, an internal convective coefficient values of 2.5 W/m2K is reported in the Standard ISO 6946. However, no exhaustive description about this value is provided. The aim of this work is to experimentally determine the internal thermal surface resistance, quantifying how the convective heat transfer coefficient varies as air velocity changes.
format article
author de Rubeis Tullio
Evangelisti Luca
Guattari Claudia
De Lieto Vollaro Roberto
Asdrubali Francesco
Ambrosini Dario
Paoletti Domenica
author_facet de Rubeis Tullio
Evangelisti Luca
Guattari Claudia
De Lieto Vollaro Roberto
Asdrubali Francesco
Ambrosini Dario
Paoletti Domenica
author_sort de Rubeis Tullio
title Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
title_short Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
title_full Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
title_fullStr Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
title_full_unstemmed Influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
title_sort influence of environmental boundary conditions on convective heat transfer coefficients of wall internal surface
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/1f0bd0bc09cf4f7c96e7454d62097bef
work_keys_str_mv AT derubeistullio influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
AT evangelistiluca influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
AT guattariclaudia influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
AT delietovollaroroberto influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
AT asdrubalifrancesco influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
AT ambrosinidario influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
AT paolettidomenica influenceofenvironmentalboundaryconditionsonconvectiveheattransfercoefficientsofwallinternalsurface
_version_ 1718442022476447744