Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method

Guangtai Shen, 1 Xiaoqiang Yu, 1 Tianyang Sun, 1 Tian Hou, 1 Heping He, 1 Tubuxin Bai, 1 Zhipeng Zhang, 1 Xiaoli Ding, 1 Qingping Li, 2 Ying Liang, 3 Yuhua Ma 4 1Department of Breast and Thyroid Surgery, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 1...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Shen G, Yu X, Sun T, Hou T, He H, Bai T, Zhang Z, Ding X, Li Q, Liang Y, Ma Y
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/1fabd3dc164f4dd5906a4552f2d4e10f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:1fabd3dc164f4dd5906a4552f2d4e10f
record_format dspace
spelling oai:doaj.org-article:1fabd3dc164f4dd5906a4552f2d4e10f2021-12-02T19:17:36ZVerification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method1178-7074https://doaj.org/article/1fabd3dc164f4dd5906a4552f2d4e10f2021-12-01T00:00:00Zhttps://www.dovepress.com/verification-of-volume-similarity-between-unilateral-mammary-gland-and-peer-reviewed-fulltext-article-IJGMhttps://doaj.org/toc/1178-7074Guangtai Shen, 1 Xiaoqiang Yu, 1 Tianyang Sun, 1 Tian Hou, 1 Heping He, 1 Tubuxin Bai, 1 Zhipeng Zhang, 1 Xiaoli Ding, 1 Qingping Li, 2 Ying Liang, 3 Yuhua Ma 4 1Department of Breast and Thyroid Surgery, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of China; 2Department of Operating Room, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of China; 3Department of Pathology, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of China; 4Department of Anesthesiology, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of ChinaCorrespondence: Xiaoqiang YuDepartment of Breast and Thyroid Surgery, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of ChinaTel/Fax +86 0482-8413761Email yuxq66_dr@163.comObjective: To verify the volume similarity between unilateral mammary gland and autologous omentum in adult females.Methods: A total of 63 patients diagnosed with stage 0–II breast cancer and partial non-lactating multi-fistula mastitis in the breast surgery department of Inner Mongolia Xing’an League People’s Hospital from 2007 to 2020 were enrolled in the study, including 52 cases of stage 0–II breast cancer and 11 cases of non-lactating multi-fistula mastitis. The volume of the resected mammary gland and the omentum were measured by a “soft tissue measuring cylinder” and recorded. The appearance of the reconstructed breast was compared with that of the healthy side. The correlation between unilateral mammary gland volume and autologous omentum volume was analyzed by linear regression.Results: Valid data were obtained for 60 cases. Affected breast size, curve, texture, nipple, and inframammary fold after omentum breast reconstruction were similar and symmetrical to those of the unaffected side. Postoperative complications occurred in most patients; the majority of these (76.67%) involved numbness of the nipple, and other complications were few. Patient satisfaction with postoperative appearance, feel, and movement of the breast, as well as total treatment costs, was over 75.0%. Linear regression analysis indicates a linear relationship between subcutaneous gland volume (x) and autologous omentum volume (y): y = 0.9847x - 1.2132, R 2 = 0.9742.Conclusion: Only when the dissociated pedicled omentum is completely obtained under laparoscopy can the whole subcutaneous residual cavity of the mammary gland be filled to the same volume. This study verifies that the volume of the unilateral mammary gland is similar to that of the autologous omentum in adult females.Keywords: unilateral mammary gland, omentum, volume, similarity, laparoscope, breast reconstructionShen GYu XSun THou THe HBai TZhang ZDing XLi QLiang YMa YDove Medical Pressarticleunilateral mammary glandomentumvolumesimilaritylaparoscopebreast reconstructionMedicine (General)R5-920ENInternational Journal of General Medicine, Vol Volume 14, Pp 9211-9218 (2021)
institution DOAJ
collection DOAJ
language EN
topic unilateral mammary gland
omentum
volume
similarity
laparoscope
breast reconstruction
Medicine (General)
R5-920
spellingShingle unilateral mammary gland
omentum
volume
similarity
laparoscope
breast reconstruction
Medicine (General)
R5-920
Shen G
Yu X
Sun T
Hou T
He H
Bai T
Zhang Z
Ding X
Li Q
Liang Y
Ma Y
Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method
description Guangtai Shen, 1 Xiaoqiang Yu, 1 Tianyang Sun, 1 Tian Hou, 1 Heping He, 1 Tubuxin Bai, 1 Zhipeng Zhang, 1 Xiaoli Ding, 1 Qingping Li, 2 Ying Liang, 3 Yuhua Ma 4 1Department of Breast and Thyroid Surgery, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of China; 2Department of Operating Room, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of China; 3Department of Pathology, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of China; 4Department of Anesthesiology, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of ChinaCorrespondence: Xiaoqiang YuDepartment of Breast and Thyroid Surgery, Inner Mongolia Xing’an League People’s Hospital, Ulanhot, Inner Mongolia, 137400, People’s Republic of ChinaTel/Fax +86 0482-8413761Email yuxq66_dr@163.comObjective: To verify the volume similarity between unilateral mammary gland and autologous omentum in adult females.Methods: A total of 63 patients diagnosed with stage 0–II breast cancer and partial non-lactating multi-fistula mastitis in the breast surgery department of Inner Mongolia Xing’an League People’s Hospital from 2007 to 2020 were enrolled in the study, including 52 cases of stage 0–II breast cancer and 11 cases of non-lactating multi-fistula mastitis. The volume of the resected mammary gland and the omentum were measured by a “soft tissue measuring cylinder” and recorded. The appearance of the reconstructed breast was compared with that of the healthy side. The correlation between unilateral mammary gland volume and autologous omentum volume was analyzed by linear regression.Results: Valid data were obtained for 60 cases. Affected breast size, curve, texture, nipple, and inframammary fold after omentum breast reconstruction were similar and symmetrical to those of the unaffected side. Postoperative complications occurred in most patients; the majority of these (76.67%) involved numbness of the nipple, and other complications were few. Patient satisfaction with postoperative appearance, feel, and movement of the breast, as well as total treatment costs, was over 75.0%. Linear regression analysis indicates a linear relationship between subcutaneous gland volume (x) and autologous omentum volume (y): y = 0.9847x - 1.2132, R 2 = 0.9742.Conclusion: Only when the dissociated pedicled omentum is completely obtained under laparoscopy can the whole subcutaneous residual cavity of the mammary gland be filled to the same volume. This study verifies that the volume of the unilateral mammary gland is similar to that of the autologous omentum in adult females.Keywords: unilateral mammary gland, omentum, volume, similarity, laparoscope, breast reconstruction
format article
author Shen G
Yu X
Sun T
Hou T
He H
Bai T
Zhang Z
Ding X
Li Q
Liang Y
Ma Y
author_facet Shen G
Yu X
Sun T
Hou T
He H
Bai T
Zhang Z
Ding X
Li Q
Liang Y
Ma Y
author_sort Shen G
title Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method
title_short Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method
title_full Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method
title_fullStr Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method
title_full_unstemmed Verification of Volume Similarity Between Unilateral Mammary Gland and Autologous Omentum in Adult Women by Measuring Cylinder Method
title_sort verification of volume similarity between unilateral mammary gland and autologous omentum in adult women by measuring cylinder method
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/1fabd3dc164f4dd5906a4552f2d4e10f
work_keys_str_mv AT sheng verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT yux verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT sunt verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT hout verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT heh verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT bait verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT zhangz verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT dingx verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT liq verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT liangy verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
AT may verificationofvolumesimilaritybetweenunilateralmammaryglandandautologousomentuminadultwomenbymeasuringcylindermethod
_version_ 1718376901289967616