Left ventricular longitudinal strain variations assessed by speckle-tracking echocardiography after a passive leg raising maneuver in patients with acute circulatory failure to predict fluid responsiveness: A prospective, observational study.
<h4>Background</h4>An association was reported between the left ventricular longitudinal strain (LV-LS) and preload. LV-LS reflects the left cardiac function curve as it is the ratio of shortening over diastolic dimension. The aim of this study was to determine the sensitivity and specif...
Guardado en:
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Public Library of Science (PLoS)
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/1fe6d3640a134064825cc71e04c332f2 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | <h4>Background</h4>An association was reported between the left ventricular longitudinal strain (LV-LS) and preload. LV-LS reflects the left cardiac function curve as it is the ratio of shortening over diastolic dimension. The aim of this study was to determine the sensitivity and specificity of LV-LS variations after a passive leg raising (PLR) maneuver to predict fluid responsiveness in intensive care unit (ICU) patients with acute circulatory failure (ACF).<h4>Methods</h4>Patients with ACF were prospectively included. Preload-dependency was defined as a velocity time integral (VTI) variation greater than 10% between baseline (T0) and PLR (T1), distinguishing the preload-dependent (PLD+) group and the preload-independent (PLD-) group. A 7-cycles, 4-chamber echocardiography loop was registered at T0 and T1, and strain analysis was performed off-line by a blind clinician. A general linear model for repeated measures was used to compare the LV-LS variation (T0 to T1) between the two groups.<h4>Results</h4>From June 2018 to August 2019, 60 patients (PLD+ = 33, PLD- = 27) were consecutively enrolled. The VTI variations after PLR were +21% (±8) in the PLD+ group and -1% (±7) in the PLD- group (p<0.01). Mean baseline LV-LS was -11.3% (±4.2) in the PLD+ group and -13.0% (±4.2) in the PLD- group (p = 0.12). LV-LS increased in the whole population after PLR +16.0% (±4.0) (p = 0.04). The LV-LS variations after PLR were +19.0% (±31) (p = 0.05) in the PLD+ group and +11.0% (±38) (p = 0.25) in the PLD- group, with no significant difference between the two groups (p = 0.08). The area under the curve for the LV-LS variations between T0 and T1 was 0.63 [0.48-0.77].<h4>Conclusion</h4>Our study confirms that LV-LS is load-dependent; however, the variations in LV-LS after PLR is not a discriminating criterion to predict fluid responsiveness of ICU patients with ACF in this cohort. |
---|