Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow
Ventilation technology in German operating rooms is regulated by DIN 1946-4. Since the release of the latest version in 2018, a positioning analysis (worst-case scenario with the largest space requirement) for determining the required protected area in class 1a operating rooms is mandatory. The aim...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
De Gruyter
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2008c20df660447b847a712d848debe5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:2008c20df660447b847a712d848debe5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2008c20df660447b847a712d848debe52021-12-05T14:10:42ZRelevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow2364-550410.1515/cdbme-2020-3078https://doaj.org/article/2008c20df660447b847a712d848debe52020-09-01T00:00:00Zhttps://doi.org/10.1515/cdbme-2020-3078https://doaj.org/toc/2364-5504Ventilation technology in German operating rooms is regulated by DIN 1946-4. Since the release of the latest version in 2018, a positioning analysis (worst-case scenario with the largest space requirement) for determining the required protected area in class 1a operating rooms is mandatory. The aim of this investigation was to use typical workflow scenarios to assess existing installations regarding the match of the required and the built size of the protected area. Positioning analyses were carried out together with the on-site staff for various clinical procedures in 2 hospitals to assess the built versus required protected areas. In all cases, the positioning analysis revealed that required protected areas need to be significantly larger than provided by the existing setup. The size of the protected area that is actually required can only be determined by individual positioning analysis. Most existing installations of low turbulence displacement flow systems (TAV) are likely to be too small. The larger protected areas actually require significantly larger rooms in order to maintain proper thermodynamics. Furthermore, significantly higher volumetric flow rates are required. Finally, the current mismatch between actual and necessary protected area would be a possible explanation for the controversial data situation regarding the infection preventive effects of TAV systems.Bulitta ClemensSchlautmann BurkhardDe Gruyterarticledin 1946-4:2018positioning analysistav systemprotected areasurgical site infectionsMedicineRENCurrent Directions in Biomedical Engineering, Vol 6, Iss 3, Pp 304-306 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
din 1946-4:2018 positioning analysis tav system protected area surgical site infections Medicine R |
spellingShingle |
din 1946-4:2018 positioning analysis tav system protected area surgical site infections Medicine R Bulitta Clemens Schlautmann Burkhard Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
description |
Ventilation technology in German operating rooms is regulated by DIN 1946-4. Since the release of the latest version in 2018, a positioning analysis (worst-case scenario with the largest space requirement) for determining the required protected area in class 1a operating rooms is mandatory. The aim of this investigation was to use typical workflow scenarios to assess existing installations regarding the match of the required and the built size of the protected area. Positioning analyses were carried out together with the on-site staff for various clinical procedures in 2 hospitals to assess the built versus required protected areas. In all cases, the positioning analysis revealed that required protected areas need to be significantly larger than provided by the existing setup. The size of the protected area that is actually required can only be determined by individual positioning analysis. Most existing installations of low turbulence displacement flow systems (TAV) are likely to be too small. The larger protected areas actually require significantly larger rooms in order to maintain proper thermodynamics. Furthermore, significantly higher volumetric flow rates are required. Finally, the current mismatch between actual and necessary protected area would be a possible explanation for the controversial data situation regarding the infection preventive effects of TAV systems. |
format |
article |
author |
Bulitta Clemens Schlautmann Burkhard |
author_facet |
Bulitta Clemens Schlautmann Burkhard |
author_sort |
Bulitta Clemens |
title |
Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
title_short |
Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
title_full |
Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
title_fullStr |
Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
title_full_unstemmed |
Relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
title_sort |
relevance and implications of positioning analysis for infection-preventive effectiveness of ventilation systems with low-turbulence dis-placement flow |
publisher |
De Gruyter |
publishDate |
2020 |
url |
https://doaj.org/article/2008c20df660447b847a712d848debe5 |
work_keys_str_mv |
AT bulittaclemens relevanceandimplicationsofpositioninganalysisforinfectionpreventiveeffectivenessofventilationsystemswithlowturbulencedisplacementflow AT schlautmannburkhard relevanceandimplicationsofpositioninganalysisforinfectionpreventiveeffectivenessofventilationsystemswithlowturbulencedisplacementflow |
_version_ |
1718371828031815680 |