Comparison of micro-CT imaging and histology for approximal caries detection

Abstract Histological sectioning is a generally accepted in vitro validation method for caries detection techniques. However, it requires cumbersome sample preparation and induces irreversible sample destruction. Micro-Computer Tomography (micro-CT) allows non-destructive imaging of tooth structure....

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: C. Boca, B. Truyen, L. Henin, A. G. Schulte, V. Stachniss, N. De Clerck, J. Cornelis, P. Bottenberg
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/208f54cc98304d9f8e6d13a852876967
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:208f54cc98304d9f8e6d13a852876967
record_format dspace
spelling oai:doaj.org-article:208f54cc98304d9f8e6d13a8528769672021-12-02T16:06:10ZComparison of micro-CT imaging and histology for approximal caries detection10.1038/s41598-017-06735-62045-2322https://doaj.org/article/208f54cc98304d9f8e6d13a8528769672017-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-06735-6https://doaj.org/toc/2045-2322Abstract Histological sectioning is a generally accepted in vitro validation method for caries detection techniques. However, it requires cumbersome sample preparation and induces irreversible sample destruction. Micro-Computer Tomography (micro-CT) allows non-destructive imaging of tooth structure. The aim of this study was to compare the performance of histological sectioning and micro-CT imaging in detecting approximal carious lesions. Unlike previous studies, evaluation is objectified by comparing visual appearance of exactly corresponding anatomical regions. Sixty extracted human teeth were scanned with a desktop micro CT system. Axial histological slices were prepared and photographed. Sample preparation, combined with dedicated image processing, ensured selection of identical anatomical regions on radiographic and histological images. Evaluation of the presence and extent of carious lesions was performed by four dentists using custom-designed software. Each section was scored independently (histo or micro CT). Scores of approximal surfaces were retained for further analysis. Spearman’s correlation coefficients (0.738 to 0.829, p < 0.0001) showed a good agreement between signs of carious lesions in the identical region obtained with both methods. Bland-Altman plots showed that 90.76% of the data points were within the limits of agreement. Micro-CT imaging was shown to provide an interesting alternative to histological sectioning as detection method for carious lesions.C. BocaB. TruyenL. HeninA. G. SchulteV. StachnissN. De ClerckJ. CornelisP. BottenbergNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
C. Boca
B. Truyen
L. Henin
A. G. Schulte
V. Stachniss
N. De Clerck
J. Cornelis
P. Bottenberg
Comparison of micro-CT imaging and histology for approximal caries detection
description Abstract Histological sectioning is a generally accepted in vitro validation method for caries detection techniques. However, it requires cumbersome sample preparation and induces irreversible sample destruction. Micro-Computer Tomography (micro-CT) allows non-destructive imaging of tooth structure. The aim of this study was to compare the performance of histological sectioning and micro-CT imaging in detecting approximal carious lesions. Unlike previous studies, evaluation is objectified by comparing visual appearance of exactly corresponding anatomical regions. Sixty extracted human teeth were scanned with a desktop micro CT system. Axial histological slices were prepared and photographed. Sample preparation, combined with dedicated image processing, ensured selection of identical anatomical regions on radiographic and histological images. Evaluation of the presence and extent of carious lesions was performed by four dentists using custom-designed software. Each section was scored independently (histo or micro CT). Scores of approximal surfaces were retained for further analysis. Spearman’s correlation coefficients (0.738 to 0.829, p < 0.0001) showed a good agreement between signs of carious lesions in the identical region obtained with both methods. Bland-Altman plots showed that 90.76% of the data points were within the limits of agreement. Micro-CT imaging was shown to provide an interesting alternative to histological sectioning as detection method for carious lesions.
format article
author C. Boca
B. Truyen
L. Henin
A. G. Schulte
V. Stachniss
N. De Clerck
J. Cornelis
P. Bottenberg
author_facet C. Boca
B. Truyen
L. Henin
A. G. Schulte
V. Stachniss
N. De Clerck
J. Cornelis
P. Bottenberg
author_sort C. Boca
title Comparison of micro-CT imaging and histology for approximal caries detection
title_short Comparison of micro-CT imaging and histology for approximal caries detection
title_full Comparison of micro-CT imaging and histology for approximal caries detection
title_fullStr Comparison of micro-CT imaging and histology for approximal caries detection
title_full_unstemmed Comparison of micro-CT imaging and histology for approximal caries detection
title_sort comparison of micro-ct imaging and histology for approximal caries detection
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/208f54cc98304d9f8e6d13a852876967
work_keys_str_mv AT cboca comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT btruyen comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT lhenin comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT agschulte comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT vstachniss comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT ndeclerck comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT jcornelis comparisonofmicroctimagingandhistologyforapproximalcariesdetection
AT pbottenberg comparisonofmicroctimagingandhistologyforapproximalcariesdetection
_version_ 1718385075396018176