Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons

Abstract Kyphoplasty (KP) with intravertebral reduction devices (IRD) was reported to be associated with better radiological outcomes than KP with balloons (BK) for osteoporotic vertebral compression fractures (OVCFs). However, the mechanical factors that contribute to the radiological benefits of I...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Chi-Jung Chiang, Jin-Wei Huang, Shu-Mei Chen, Jiann-Her Lin
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/214bdebb6e934b5480bc1149a7305bc7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:214bdebb6e934b5480bc1149a7305bc7
record_format dspace
spelling oai:doaj.org-article:214bdebb6e934b5480bc1149a7305bc72021-12-02T11:37:26ZKyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons10.1038/s41598-021-84856-92045-2322https://doaj.org/article/214bdebb6e934b5480bc1149a7305bc72021-03-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-84856-9https://doaj.org/toc/2045-2322Abstract Kyphoplasty (KP) with intravertebral reduction devices (IRD) was reported to be associated with better radiological outcomes than KP with balloons (BK) for osteoporotic vertebral compression fractures (OVCFs). However, the mechanical factors that contribute to the radiological benefits of IRDs require further investigation. To probe the mechanical factors, this retrospective matched cohort study was designed, including the older patients with painful OVCFs and treated with KP. We compared the clinical and radiological outcomes between KP with an IRD and BK, where vertebral body height and kyphotic angle of the cemented vertebrae were measured pre- and postoperatively; clinical outcomes were collected by telephone interviews. The restoration and maintenance ratio suggested that IRDs were associated with favorable effects long-term wise in anterior to middle vertebral body and kyphosis than BK in patients. The gathered results concluded the radiological benefits of IRD regarding both its efficient restoration and maintenance in vertebrae.Chi-Jung ChiangJin-Wei HuangShu-Mei ChenJiann-Her LinNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Chi-Jung Chiang
Jin-Wei Huang
Shu-Mei Chen
Jiann-Her Lin
Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
description Abstract Kyphoplasty (KP) with intravertebral reduction devices (IRD) was reported to be associated with better radiological outcomes than KP with balloons (BK) for osteoporotic vertebral compression fractures (OVCFs). However, the mechanical factors that contribute to the radiological benefits of IRDs require further investigation. To probe the mechanical factors, this retrospective matched cohort study was designed, including the older patients with painful OVCFs and treated with KP. We compared the clinical and radiological outcomes between KP with an IRD and BK, where vertebral body height and kyphotic angle of the cemented vertebrae were measured pre- and postoperatively; clinical outcomes were collected by telephone interviews. The restoration and maintenance ratio suggested that IRDs were associated with favorable effects long-term wise in anterior to middle vertebral body and kyphosis than BK in patients. The gathered results concluded the radiological benefits of IRD regarding both its efficient restoration and maintenance in vertebrae.
format article
author Chi-Jung Chiang
Jin-Wei Huang
Shu-Mei Chen
Jiann-Her Lin
author_facet Chi-Jung Chiang
Jin-Wei Huang
Shu-Mei Chen
Jiann-Her Lin
author_sort Chi-Jung Chiang
title Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
title_short Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
title_full Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
title_fullStr Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
title_full_unstemmed Kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
title_sort kyphoplasty with intravertebral reduction devices associated with better height restoration and greater kyphosis correction than kyphoplasty with balloons
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/214bdebb6e934b5480bc1149a7305bc7
work_keys_str_mv AT chijungchiang kyphoplastywithintravertebralreductiondevicesassociatedwithbetterheightrestorationandgreaterkyphosiscorrectionthankyphoplastywithballoons
AT jinweihuang kyphoplastywithintravertebralreductiondevicesassociatedwithbetterheightrestorationandgreaterkyphosiscorrectionthankyphoplastywithballoons
AT shumeichen kyphoplastywithintravertebralreductiondevicesassociatedwithbetterheightrestorationandgreaterkyphosiscorrectionthankyphoplastywithballoons
AT jiannherlin kyphoplastywithintravertebralreductiondevicesassociatedwithbetterheightrestorationandgreaterkyphosiscorrectionthankyphoplastywithballoons
_version_ 1718395747334881280