Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal
Abstract The aim of our work was to develop a low-cost, portable device for the fast and easy determination of total protein content by using PDMS-based lab-in-a-syringe technology with removal of 3D-printed channels. We proposed two designs with a one-step PDMS curing and a two-step PDMS-curing fab...
Guardado en:
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
SpringerOpen
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/219dd575a13b47ac9d114d207314f144 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:219dd575a13b47ac9d114d207314f144 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:219dd575a13b47ac9d114d207314f1442021-11-28T12:06:08ZDetermination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal10.1186/s40543-021-00307-02093-3371https://doaj.org/article/219dd575a13b47ac9d114d207314f1442021-11-01T00:00:00Zhttps://doi.org/10.1186/s40543-021-00307-0https://doaj.org/toc/2093-3371Abstract The aim of our work was to develop a low-cost, portable device for the fast and easy determination of total protein content by using PDMS-based lab-in-a-syringe technology with removal of 3D-printed channels. We proposed two designs with a one-step PDMS curing and a two-step PDMS-curing fabrication procedure. The one-step PDMS microdevices were found to be the best in the view of preparation, repeatability, and stability of the reagent. This design was then applied for the determination of total protein content in biomedical products using the Bradford assay.Ester DrastíkováKlára KonderlováAndrea ŠebestováDaniel BaronPetra ŠvecováPetra TáborskáKateřina VítkováVeronika PospíšilováSerhiy ForostyakZdeněk KořístekLudmila PorubováJan PetrSpringerOpenarticleLab-in-a-syringe3D printingMicrofluidicsPDMSTotal protein contentChemistryQD1-999Analytical chemistryQD71-142ENJournal of Analytical Science and Technology, Vol 12, Iss 1, Pp 1-7 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Lab-in-a-syringe 3D printing Microfluidics PDMS Total protein content Chemistry QD1-999 Analytical chemistry QD71-142 |
spellingShingle |
Lab-in-a-syringe 3D printing Microfluidics PDMS Total protein content Chemistry QD1-999 Analytical chemistry QD71-142 Ester Drastíková Klára Konderlová Andrea Šebestová Daniel Baron Petra Švecová Petra Táborská Kateřina Vítková Veronika Pospíšilová Serhiy Forostyak Zdeněk Kořístek Ludmila Porubová Jan Petr Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal |
description |
Abstract The aim of our work was to develop a low-cost, portable device for the fast and easy determination of total protein content by using PDMS-based lab-in-a-syringe technology with removal of 3D-printed channels. We proposed two designs with a one-step PDMS curing and a two-step PDMS-curing fabrication procedure. The one-step PDMS microdevices were found to be the best in the view of preparation, repeatability, and stability of the reagent. This design was then applied for the determination of total protein content in biomedical products using the Bradford assay. |
format |
article |
author |
Ester Drastíková Klára Konderlová Andrea Šebestová Daniel Baron Petra Švecová Petra Táborská Kateřina Vítková Veronika Pospíšilová Serhiy Forostyak Zdeněk Kořístek Ludmila Porubová Jan Petr |
author_facet |
Ester Drastíková Klára Konderlová Andrea Šebestová Daniel Baron Petra Švecová Petra Táborská Kateřina Vítková Veronika Pospíšilová Serhiy Forostyak Zdeněk Kořístek Ludmila Porubová Jan Petr |
author_sort |
Ester Drastíková |
title |
Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal |
title_short |
Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal |
title_full |
Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal |
title_fullStr |
Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal |
title_full_unstemmed |
Determination of total protein content in biomedical products by the PDMS-assisted lab-in-a-syringe assay using 3D printed scaffolds removal |
title_sort |
determination of total protein content in biomedical products by the pdms-assisted lab-in-a-syringe assay using 3d printed scaffolds removal |
publisher |
SpringerOpen |
publishDate |
2021 |
url |
https://doaj.org/article/219dd575a13b47ac9d114d207314f144 |
work_keys_str_mv |
AT esterdrastikova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT klarakonderlova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT andreasebestova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT danielbaron determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT petrasvecova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT petrataborska determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT katerinavitkova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT veronikapospisilova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT serhiyforostyak determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT zdenekkoristek determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT ludmilaporubova determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval AT janpetr determinationoftotalproteincontentinbiomedicalproductsbythepdmsassistedlabinasyringeassayusing3dprintedscaffoldsremoval |
_version_ |
1718408186689486848 |