Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange

Kinza T Ahmad,1 Ahmed B Sallam,1 Ahmed A Saad,2,3 Abdallah A Ellabban4,5 1Harvey and Bernice Jones Eye Institute, University of Arkansas for the Medical Sciences, Little Rock, AR, USA; 2Zagazig University, Zagazig, Egypt; 3James Cook University Hospital, Middlesbrough, UK; 4Hull University Teaching...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ahmad KT, Sallam AB, Saad AA, Ellabban AA
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/21f9b7a082a44eeb873315117afc9e98
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:21f9b7a082a44eeb873315117afc9e98
record_format dspace
spelling oai:doaj.org-article:21f9b7a082a44eeb873315117afc9e982021-12-02T12:33:21ZFully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange1177-5483https://doaj.org/article/21f9b7a082a44eeb873315117afc9e982020-12-01T00:00:00Zhttps://www.dovepress.com/fully-automated-direct-perfluorocarbon-liquid-silicone-oil-exchange-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Kinza T Ahmad,1 Ahmed B Sallam,1 Ahmed A Saad,2,3 Abdallah A Ellabban4,5 1Harvey and Bernice Jones Eye Institute, University of Arkansas for the Medical Sciences, Little Rock, AR, USA; 2Zagazig University, Zagazig, Egypt; 3James Cook University Hospital, Middlesbrough, UK; 4Hull University Teaching Hospitals, Hull, UK; 5Suez Canal University, Ismailia, EgyptCorrespondence: Abdallah A EllabbanHull University Teaching Hospitals, Anlaby Road, Hull HU3 2JZ, UKTel +44 7459328031Fax +44 1482604327Email ellabbanabdallah@gmail.comPurpose: To demonstrate a modified technique of fully automated direct perfluorocarbon liquid (PFCL)-silicone oil (SO) exchange.Materials and Methods: This technique is indicated for cases that require direct PFCL-SO exchange as in giant retinal tear or large retinectomies to avoid retinal slippage. Pars plana vitrectomy (PPV) is carried out in standard fashion; then the dual active injection/extrusion mode is activated in the vitrectomy machine. The machine parameters are set at approximately 30– 40 psi for SO injection and 150– 250 mmHg for active PFCL aspiration. In this method, both the SO injection and the PFCL extrusion are simultaneously controlled by the foot pedal.Results: We used this technique for a total of 24 cases: 6 cases of giant retinal tears and 18 retinectomies. We did not encounter any complications related to significant IOP spike during surgery or complete removal of the PFCL.Conclusion: This automated technique for direct PFCL-SO exchange maintains a controlled balance between SO injection and PFCL aspiration, that mitigates the risk of intraoperative IOP spikes. It is safe, quick, and can be performed without the need of an assistant or extra chandelier light or high-pressure viscous tubing.Keywords: giant retinal tear, retinectomy, perfluorocarbon liquid, PFCL, silicone oil, vitrectomyAhmad KTSallam ABSaad AAEllabban AADove Medical Pressarticlegiant retinal tearretinectomyperfluorocarbon liquidpfclsilicone oilvitrectomyOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 4355-4358 (2020)
institution DOAJ
collection DOAJ
language EN
topic giant retinal tear
retinectomy
perfluorocarbon liquid
pfcl
silicone oil
vitrectomy
Ophthalmology
RE1-994
spellingShingle giant retinal tear
retinectomy
perfluorocarbon liquid
pfcl
silicone oil
vitrectomy
Ophthalmology
RE1-994
Ahmad KT
Sallam AB
Saad AA
Ellabban AA
Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange
description Kinza T Ahmad,1 Ahmed B Sallam,1 Ahmed A Saad,2,3 Abdallah A Ellabban4,5 1Harvey and Bernice Jones Eye Institute, University of Arkansas for the Medical Sciences, Little Rock, AR, USA; 2Zagazig University, Zagazig, Egypt; 3James Cook University Hospital, Middlesbrough, UK; 4Hull University Teaching Hospitals, Hull, UK; 5Suez Canal University, Ismailia, EgyptCorrespondence: Abdallah A EllabbanHull University Teaching Hospitals, Anlaby Road, Hull HU3 2JZ, UKTel +44 7459328031Fax +44 1482604327Email ellabbanabdallah@gmail.comPurpose: To demonstrate a modified technique of fully automated direct perfluorocarbon liquid (PFCL)-silicone oil (SO) exchange.Materials and Methods: This technique is indicated for cases that require direct PFCL-SO exchange as in giant retinal tear or large retinectomies to avoid retinal slippage. Pars plana vitrectomy (PPV) is carried out in standard fashion; then the dual active injection/extrusion mode is activated in the vitrectomy machine. The machine parameters are set at approximately 30– 40 psi for SO injection and 150– 250 mmHg for active PFCL aspiration. In this method, both the SO injection and the PFCL extrusion are simultaneously controlled by the foot pedal.Results: We used this technique for a total of 24 cases: 6 cases of giant retinal tears and 18 retinectomies. We did not encounter any complications related to significant IOP spike during surgery or complete removal of the PFCL.Conclusion: This automated technique for direct PFCL-SO exchange maintains a controlled balance between SO injection and PFCL aspiration, that mitigates the risk of intraoperative IOP spikes. It is safe, quick, and can be performed without the need of an assistant or extra chandelier light or high-pressure viscous tubing.Keywords: giant retinal tear, retinectomy, perfluorocarbon liquid, PFCL, silicone oil, vitrectomy
format article
author Ahmad KT
Sallam AB
Saad AA
Ellabban AA
author_facet Ahmad KT
Sallam AB
Saad AA
Ellabban AA
author_sort Ahmad KT
title Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange
title_short Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange
title_full Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange
title_fullStr Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange
title_full_unstemmed Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange
title_sort fully automated direct perfluorocarbon liquid-silicone oil exchange
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/21f9b7a082a44eeb873315117afc9e98
work_keys_str_mv AT ahmadkt fullyautomateddirectperfluorocarbonliquidsiliconeoilexchange
AT sallamab fullyautomateddirectperfluorocarbonliquidsiliconeoilexchange
AT saadaa fullyautomateddirectperfluorocarbonliquidsiliconeoilexchange
AT ellabbanaa fullyautomateddirectperfluorocarbonliquidsiliconeoilexchange
_version_ 1718393847544807424