Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration

Abstract Water removal which is a key treatment goal of automated peritoneal dialysis (APD) can be assessed cycle-by-cycle using remote patient monitoring (RPM). We analysed ultrafiltration patterns during night APD following a dry day (APDDD; no daytime fluid exchange) or wet day (APDWD; daytime ex...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Joanna Stachowska-Pietka, Beata Naumnik, Ewa Suchowierska, Rafael Gomez, Jacek Waniewski, Bengt Lindholm
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/22a8b53607fe4a77b458721c642ac6e5
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:22a8b53607fe4a77b458721c642ac6e5
record_format dspace
spelling oai:doaj.org-article:22a8b53607fe4a77b458721c642ac6e52021-12-02T17:06:09ZWater removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration10.1038/s41598-021-95001-x2045-2322https://doaj.org/article/22a8b53607fe4a77b458721c642ac6e52021-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-95001-xhttps://doaj.org/toc/2045-2322Abstract Water removal which is a key treatment goal of automated peritoneal dialysis (APD) can be assessed cycle-by-cycle using remote patient monitoring (RPM). We analysed ultrafiltration patterns during night APD following a dry day (APDDD; no daytime fluid exchange) or wet day (APDWD; daytime exchange). Ultrafiltration for each APD exchange were recorded for 16 days using RPM in 14 patients. The distributed model of fluid and solute transport was applied to simulate APD and to explore the impact of changes in peritoneal tissue hydration on ultrafiltration. We found lower ultrafiltration (mL, median [first quartile, third quartile]) during first and second vs. consecutive exchanges in APDDD (−61 [−148, 27], 170 [78, 228] vs. 213 [126, 275] mL; p < 0.001), but not in APDWD (81 [−8, 176], 81 [−4, 192] vs. 115 [4, 219] mL; NS). Simulations in a virtual patient showed that lower ultrafiltration (by 114 mL) was related to increased peritoneal tissue hydration caused by inflow of 187 mL of water during the first APDDD exchange. The observed phenomenon of lower ultrafiltration during initial exchanges of dialysis fluid in patients undergoing APDDD appears to be due to water inflow into the peritoneal tissue, re-establishing a state of increased hydration typical for peritoneal dialysis.Joanna Stachowska-PietkaBeata NaumnikEwa SuchowierskaRafael GomezJacek WaniewskiBengt LindholmNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-10 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Joanna Stachowska-Pietka
Beata Naumnik
Ewa Suchowierska
Rafael Gomez
Jacek Waniewski
Bengt Lindholm
Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
description Abstract Water removal which is a key treatment goal of automated peritoneal dialysis (APD) can be assessed cycle-by-cycle using remote patient monitoring (RPM). We analysed ultrafiltration patterns during night APD following a dry day (APDDD; no daytime fluid exchange) or wet day (APDWD; daytime exchange). Ultrafiltration for each APD exchange were recorded for 16 days using RPM in 14 patients. The distributed model of fluid and solute transport was applied to simulate APD and to explore the impact of changes in peritoneal tissue hydration on ultrafiltration. We found lower ultrafiltration (mL, median [first quartile, third quartile]) during first and second vs. consecutive exchanges in APDDD (−61 [−148, 27], 170 [78, 228] vs. 213 [126, 275] mL; p < 0.001), but not in APDWD (81 [−8, 176], 81 [−4, 192] vs. 115 [4, 219] mL; NS). Simulations in a virtual patient showed that lower ultrafiltration (by 114 mL) was related to increased peritoneal tissue hydration caused by inflow of 187 mL of water during the first APDDD exchange. The observed phenomenon of lower ultrafiltration during initial exchanges of dialysis fluid in patients undergoing APDDD appears to be due to water inflow into the peritoneal tissue, re-establishing a state of increased hydration typical for peritoneal dialysis.
format article
author Joanna Stachowska-Pietka
Beata Naumnik
Ewa Suchowierska
Rafael Gomez
Jacek Waniewski
Bengt Lindholm
author_facet Joanna Stachowska-Pietka
Beata Naumnik
Ewa Suchowierska
Rafael Gomez
Jacek Waniewski
Bengt Lindholm
author_sort Joanna Stachowska-Pietka
title Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
title_short Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
title_full Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
title_fullStr Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
title_full_unstemmed Water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
title_sort water removal during automated peritoneal dialysis assessed by remote patient monitoring and modelling of peritoneal tissue hydration
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/22a8b53607fe4a77b458721c642ac6e5
work_keys_str_mv AT joannastachowskapietka waterremovalduringautomatedperitonealdialysisassessedbyremotepatientmonitoringandmodellingofperitonealtissuehydration
AT beatanaumnik waterremovalduringautomatedperitonealdialysisassessedbyremotepatientmonitoringandmodellingofperitonealtissuehydration
AT ewasuchowierska waterremovalduringautomatedperitonealdialysisassessedbyremotepatientmonitoringandmodellingofperitonealtissuehydration
AT rafaelgomez waterremovalduringautomatedperitonealdialysisassessedbyremotepatientmonitoringandmodellingofperitonealtissuehydration
AT jacekwaniewski waterremovalduringautomatedperitonealdialysisassessedbyremotepatientmonitoringandmodellingofperitonealtissuehydration
AT bengtlindholm waterremovalduringautomatedperitonealdialysisassessedbyremotepatientmonitoringandmodellingofperitonealtissuehydration
_version_ 1718381719442161664