Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma

Abstract We evaluated the inter-physician variability in the target contouring of the radiotherapy for anal squamous cell carcinoma (ASCC). Clinical target volume (CTV) of three patients diagnosed with ASCC was delineated by seven experienced radiation oncologists from multi-institution. These patie...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kyung Su Kim, Kwang-Ho Cheong, Kyubo Kim, Taeryool Koo, Hyeon Kang Koh, Ji Hyun Chang, Ah Ram Chang, Hae Jin Park
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/22d7aa4645944c84831596e74ee079b8
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:22d7aa4645944c84831596e74ee079b8
record_format dspace
spelling oai:doaj.org-article:22d7aa4645944c84831596e74ee079b82021-12-02T14:06:55ZInterobserver variability in clinical target volume delineation in anal squamous cell carcinoma10.1038/s41598-021-82541-52045-2322https://doaj.org/article/22d7aa4645944c84831596e74ee079b82021-02-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-82541-5https://doaj.org/toc/2045-2322Abstract We evaluated the inter-physician variability in the target contouring of the radiotherapy for anal squamous cell carcinoma (ASCC). Clinical target volume (CTV) of three patients diagnosed with ASCC was delineated by seven experienced radiation oncologists from multi-institution. These patients were staged as pT1N1a, cT2N0, and cT4N1a, respectively, according to 8th edition of the American Joint Committee on Cancer staging system. Expert agreement was quantified using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE). The maximum distance from the boundaries of the STAPLE generated volume with confidence level of 80% to those of the contour of each CTV in 6 directions was compared. CTV of pelvis which includes primary tumor, perirectal tissue and internal/external iliac lymph node (LN) area (CTV-pelvis) and CTV of inguinal area (CTV-inguinal) were obtained from the seven radiation oncologists. One radiation oncologist did not contain inguinal LN area in the treatment target volume of patient 2 (cT2N0 stage). CTV-inguinal displayed moderate agreement for each patient (overall kappa 0.58, 0.54 and 0.6, respectively), whereas CTV-pelvis showed substantial agreement (overall kappa 0.66, 0.68 and 0.64, respectively). Largest variation among each contour was shown in the inferior margin of the CTV-inguinal. For CTV-pelvis, anterior and superior margin showed the biggest variation. Overall, moderate to substantial agreement was shown for CTV delineation. However, large variations in the anterior and cranial boarder of the CTV-pelvis and the caudal margin of the CTV-inguinal suggest that further studies are needed to establish a clearer target volume delineation guideline.Kyung Su KimKwang-Ho CheongKyubo KimTaeryool KooHyeon Kang KohJi Hyun ChangAh Ram ChangHae Jin ParkNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Kyung Su Kim
Kwang-Ho Cheong
Kyubo Kim
Taeryool Koo
Hyeon Kang Koh
Ji Hyun Chang
Ah Ram Chang
Hae Jin Park
Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
description Abstract We evaluated the inter-physician variability in the target contouring of the radiotherapy for anal squamous cell carcinoma (ASCC). Clinical target volume (CTV) of three patients diagnosed with ASCC was delineated by seven experienced radiation oncologists from multi-institution. These patients were staged as pT1N1a, cT2N0, and cT4N1a, respectively, according to 8th edition of the American Joint Committee on Cancer staging system. Expert agreement was quantified using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE). The maximum distance from the boundaries of the STAPLE generated volume with confidence level of 80% to those of the contour of each CTV in 6 directions was compared. CTV of pelvis which includes primary tumor, perirectal tissue and internal/external iliac lymph node (LN) area (CTV-pelvis) and CTV of inguinal area (CTV-inguinal) were obtained from the seven radiation oncologists. One radiation oncologist did not contain inguinal LN area in the treatment target volume of patient 2 (cT2N0 stage). CTV-inguinal displayed moderate agreement for each patient (overall kappa 0.58, 0.54 and 0.6, respectively), whereas CTV-pelvis showed substantial agreement (overall kappa 0.66, 0.68 and 0.64, respectively). Largest variation among each contour was shown in the inferior margin of the CTV-inguinal. For CTV-pelvis, anterior and superior margin showed the biggest variation. Overall, moderate to substantial agreement was shown for CTV delineation. However, large variations in the anterior and cranial boarder of the CTV-pelvis and the caudal margin of the CTV-inguinal suggest that further studies are needed to establish a clearer target volume delineation guideline.
format article
author Kyung Su Kim
Kwang-Ho Cheong
Kyubo Kim
Taeryool Koo
Hyeon Kang Koh
Ji Hyun Chang
Ah Ram Chang
Hae Jin Park
author_facet Kyung Su Kim
Kwang-Ho Cheong
Kyubo Kim
Taeryool Koo
Hyeon Kang Koh
Ji Hyun Chang
Ah Ram Chang
Hae Jin Park
author_sort Kyung Su Kim
title Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
title_short Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
title_full Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
title_fullStr Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
title_full_unstemmed Interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
title_sort interobserver variability in clinical target volume delineation in anal squamous cell carcinoma
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/22d7aa4645944c84831596e74ee079b8
work_keys_str_mv AT kyungsukim interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT kwanghocheong interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT kyubokim interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT taeryoolkoo interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT hyeonkangkoh interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT jihyunchang interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT ahramchang interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
AT haejinpark interobservervariabilityinclinicaltargetvolumedelineationinanalsquamouscellcarcinoma
_version_ 1718391950359396352