Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
Ventricular assistance devices (VADs) for heart failure treatment have been paid high attention among researchers for decades. However, the follow-up complications such as hemolysis and thrombosis require further optimization for this technique. Shear stress has been demonstrated to be significantly...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN FR |
Publicado: |
EDP Sciences
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/23328ac11a404aef878e81ff84828aeb |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:23328ac11a404aef878e81ff84828aeb |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:23328ac11a404aef878e81ff84828aeb2021-11-12T11:44:34ZNumerical study of shear-based hemolysis in aorta with left ventricular assistance device2267-124210.1051/e3sconf/202132103009https://doaj.org/article/23328ac11a404aef878e81ff84828aeb2021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/97/e3sconf_icchmt2021_03009.pdfhttps://doaj.org/toc/2267-1242Ventricular assistance devices (VADs) for heart failure treatment have been paid high attention among researchers for decades. However, the follow-up complications such as hemolysis and thrombosis require further optimization for this technique. Shear stress has been demonstrated to be significantly related to the hemolysis because of the rupture of red blood cells membrane with a leaking of hemoglobin in the plasma. This issue has already been investigated inside the pump of VAD, but estimations are still lacking regarding hemolysis generation in the aorta itself after VAD implantaion. Thus, the present study aims to evaluate the hemolysis in aorta through establishing the 3D numerical model of aorta with left ventricular assistance device (LVAD). Non-Newtonian Carreau model has been adopted. Comparisons of hemolysis evaluation have been made with two different mathematical models existing in literature. Moreover, the flow topology and hemodynamic variations have been studied. Different working conditions of LVAD have been considered corresponding to different heart failure severities. The results reveal a relatively low level of hemolysis risks in aorta. The thrombosis is more prone to occur in the case of severe heart failure condition.Song JianfeiMarcel LouisSpecklin MathieuKouidri SmaineEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 321, p 03009 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FR |
topic |
Environmental sciences GE1-350 |
spellingShingle |
Environmental sciences GE1-350 Song Jianfei Marcel Louis Specklin Mathieu Kouidri Smaine Numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
description |
Ventricular assistance devices (VADs) for heart failure treatment have been paid high attention among researchers for decades. However, the follow-up complications such as hemolysis and thrombosis require further optimization for this technique. Shear stress has been demonstrated to be significantly related to the hemolysis because of the rupture of red blood cells membrane with a leaking of hemoglobin in the plasma. This issue has already been investigated inside the pump of VAD, but estimations are still lacking regarding hemolysis generation in the aorta itself after VAD implantaion. Thus, the present study aims to evaluate the hemolysis in aorta through establishing the 3D numerical model of aorta with left ventricular assistance device (LVAD). Non-Newtonian Carreau model has been adopted. Comparisons of hemolysis evaluation have been made with two different mathematical models existing in literature. Moreover, the flow topology and hemodynamic variations have been studied. Different working conditions of LVAD have been considered corresponding to different heart failure severities. The results reveal a relatively low level of hemolysis risks in aorta. The thrombosis is more prone to occur in the case of severe heart failure condition. |
format |
article |
author |
Song Jianfei Marcel Louis Specklin Mathieu Kouidri Smaine |
author_facet |
Song Jianfei Marcel Louis Specklin Mathieu Kouidri Smaine |
author_sort |
Song Jianfei |
title |
Numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
title_short |
Numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
title_full |
Numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
title_fullStr |
Numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
title_full_unstemmed |
Numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
title_sort |
numerical study of shear-based hemolysis in aorta with left ventricular assistance device |
publisher |
EDP Sciences |
publishDate |
2021 |
url |
https://doaj.org/article/23328ac11a404aef878e81ff84828aeb |
work_keys_str_mv |
AT songjianfei numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice AT marcellouis numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice AT specklinmathieu numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice AT kouidrismaine numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice |
_version_ |
1718430542366507008 |