Numerical study of shear-based hemolysis in aorta with left ventricular assistance device

Ventricular assistance devices (VADs) for heart failure treatment have been paid high attention among researchers for decades. However, the follow-up complications such as hemolysis and thrombosis require further optimization for this technique. Shear stress has been demonstrated to be significantly...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Song Jianfei, Marcel Louis, Specklin Mathieu, Kouidri Smaine
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/23328ac11a404aef878e81ff84828aeb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:23328ac11a404aef878e81ff84828aeb
record_format dspace
spelling oai:doaj.org-article:23328ac11a404aef878e81ff84828aeb2021-11-12T11:44:34ZNumerical study of shear-based hemolysis in aorta with left ventricular assistance device2267-124210.1051/e3sconf/202132103009https://doaj.org/article/23328ac11a404aef878e81ff84828aeb2021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/97/e3sconf_icchmt2021_03009.pdfhttps://doaj.org/toc/2267-1242Ventricular assistance devices (VADs) for heart failure treatment have been paid high attention among researchers for decades. However, the follow-up complications such as hemolysis and thrombosis require further optimization for this technique. Shear stress has been demonstrated to be significantly related to the hemolysis because of the rupture of red blood cells membrane with a leaking of hemoglobin in the plasma. This issue has already been investigated inside the pump of VAD, but estimations are still lacking regarding hemolysis generation in the aorta itself after VAD implantaion. Thus, the present study aims to evaluate the hemolysis in aorta through establishing the 3D numerical model of aorta with left ventricular assistance device (LVAD). Non-Newtonian Carreau model has been adopted. Comparisons of hemolysis evaluation have been made with two different mathematical models existing in literature. Moreover, the flow topology and hemodynamic variations have been studied. Different working conditions of LVAD have been considered corresponding to different heart failure severities. The results reveal a relatively low level of hemolysis risks in aorta. The thrombosis is more prone to occur in the case of severe heart failure condition.Song JianfeiMarcel LouisSpecklin MathieuKouidri SmaineEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 321, p 03009 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Environmental sciences
GE1-350
spellingShingle Environmental sciences
GE1-350
Song Jianfei
Marcel Louis
Specklin Mathieu
Kouidri Smaine
Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
description Ventricular assistance devices (VADs) for heart failure treatment have been paid high attention among researchers for decades. However, the follow-up complications such as hemolysis and thrombosis require further optimization for this technique. Shear stress has been demonstrated to be significantly related to the hemolysis because of the rupture of red blood cells membrane with a leaking of hemoglobin in the plasma. This issue has already been investigated inside the pump of VAD, but estimations are still lacking regarding hemolysis generation in the aorta itself after VAD implantaion. Thus, the present study aims to evaluate the hemolysis in aorta through establishing the 3D numerical model of aorta with left ventricular assistance device (LVAD). Non-Newtonian Carreau model has been adopted. Comparisons of hemolysis evaluation have been made with two different mathematical models existing in literature. Moreover, the flow topology and hemodynamic variations have been studied. Different working conditions of LVAD have been considered corresponding to different heart failure severities. The results reveal a relatively low level of hemolysis risks in aorta. The thrombosis is more prone to occur in the case of severe heart failure condition.
format article
author Song Jianfei
Marcel Louis
Specklin Mathieu
Kouidri Smaine
author_facet Song Jianfei
Marcel Louis
Specklin Mathieu
Kouidri Smaine
author_sort Song Jianfei
title Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
title_short Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
title_full Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
title_fullStr Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
title_full_unstemmed Numerical study of shear-based hemolysis in aorta with left ventricular assistance device
title_sort numerical study of shear-based hemolysis in aorta with left ventricular assistance device
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/23328ac11a404aef878e81ff84828aeb
work_keys_str_mv AT songjianfei numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice
AT marcellouis numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice
AT specklinmathieu numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice
AT kouidrismaine numericalstudyofshearbasedhemolysisinaortawithleftventricularassistancedevice
_version_ 1718430542366507008