In Vitro Evaluation of the Wear of Three Composite Resins

BACKGROUND AND OBJECTIVE: Wear resistance of composites is important for preservation of masticatory ability and vertical height. The aim of this study was to compare wear resistance of two laboratory type composites and one direct composite.METHODS: In this in vitro study 5 samples from each type o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: AH Alhavaz, H Alaghemand, D Qujeq, R Mofidian
Formato: article
Lenguaje:EN
FA
Publicado: Babol University of Medical Sciences 2009
Materias:
R
Acceso en línea:https://doaj.org/article/23467f2849c54a65ba147f06b18d6e4a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:23467f2849c54a65ba147f06b18d6e4a
record_format dspace
spelling oai:doaj.org-article:23467f2849c54a65ba147f06b18d6e4a2021-11-10T09:03:00ZIn Vitro Evaluation of the Wear of Three Composite Resins1561-41072251-7170https://doaj.org/article/23467f2849c54a65ba147f06b18d6e4a2009-10-01T00:00:00Zhttp://jbums.org/article-1-3260-en.htmlhttps://doaj.org/toc/1561-4107https://doaj.org/toc/2251-7170BACKGROUND AND OBJECTIVE: Wear resistance of composites is important for preservation of masticatory ability and vertical height. The aim of this study was to compare wear resistance of two laboratory type composites and one direct composite.METHODS: In this in vitro study 5 samples from each type of composites (SR Adoro, GC gradia, Clearfil ST) was prepared in incremental technique. Exposure time was 40 seconds and thickness of layers was 1 mm. Wearing load was 6kg and applied via pressable chromium cobalt bar (1.98 mm2 tip) at 5000, 20000, 80000, 120000 cycles. Pre and post wearing samples weight was measured by an electronical weight balance with 0.0001 gr accuracy. The data was compared.FINDINGS: There was significant decrease in weight of all type of composites from initial weight to 120000 cycles (p≤0.001). (GC gradia 4.42±1.26mg, SR Adoro 6.5±0.89mg, Clearfil ST 4.52±2.14mg). Although after applying all wearing cycles the average decrease of weight was smaller in GC gradia rather than Clearfil St that smaller than SR Adoro, however there was no significant difference.CONCLUSION: GC gradia and Clearfil ST showed less wear than SR Adoro. There was significant wear in all types of composites in wearing cycles.AH Alhavaz,H Alaghemand,D QujeqR MofidianBabol University of Medical Sciencesarticlein vitro wearthree-body wearingcompositelaboratory compositeMedicineRMedicine (General)R5-920ENFAMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, Vol 11, Iss 4, Pp 62-68 (2009)
institution DOAJ
collection DOAJ
language EN
FA
topic in vitro wear
three-body wearing
composite
laboratory composite
Medicine
R
Medicine (General)
R5-920
spellingShingle in vitro wear
three-body wearing
composite
laboratory composite
Medicine
R
Medicine (General)
R5-920
AH Alhavaz,
H Alaghemand,
D Qujeq
R Mofidian
In Vitro Evaluation of the Wear of Three Composite Resins
description BACKGROUND AND OBJECTIVE: Wear resistance of composites is important for preservation of masticatory ability and vertical height. The aim of this study was to compare wear resistance of two laboratory type composites and one direct composite.METHODS: In this in vitro study 5 samples from each type of composites (SR Adoro, GC gradia, Clearfil ST) was prepared in incremental technique. Exposure time was 40 seconds and thickness of layers was 1 mm. Wearing load was 6kg and applied via pressable chromium cobalt bar (1.98 mm2 tip) at 5000, 20000, 80000, 120000 cycles. Pre and post wearing samples weight was measured by an electronical weight balance with 0.0001 gr accuracy. The data was compared.FINDINGS: There was significant decrease in weight of all type of composites from initial weight to 120000 cycles (p≤0.001). (GC gradia 4.42±1.26mg, SR Adoro 6.5±0.89mg, Clearfil ST 4.52±2.14mg). Although after applying all wearing cycles the average decrease of weight was smaller in GC gradia rather than Clearfil St that smaller than SR Adoro, however there was no significant difference.CONCLUSION: GC gradia and Clearfil ST showed less wear than SR Adoro. There was significant wear in all types of composites in wearing cycles.
format article
author AH Alhavaz,
H Alaghemand,
D Qujeq
R Mofidian
author_facet AH Alhavaz,
H Alaghemand,
D Qujeq
R Mofidian
author_sort AH Alhavaz,
title In Vitro Evaluation of the Wear of Three Composite Resins
title_short In Vitro Evaluation of the Wear of Three Composite Resins
title_full In Vitro Evaluation of the Wear of Three Composite Resins
title_fullStr In Vitro Evaluation of the Wear of Three Composite Resins
title_full_unstemmed In Vitro Evaluation of the Wear of Three Composite Resins
title_sort in vitro evaluation of the wear of three composite resins
publisher Babol University of Medical Sciences
publishDate 2009
url https://doaj.org/article/23467f2849c54a65ba147f06b18d6e4a
work_keys_str_mv AT ahalhavaz invitroevaluationofthewearofthreecompositeresins
AT halaghemand invitroevaluationofthewearofthreecompositeresins
AT dqujeq invitroevaluationofthewearofthreecompositeresins
AT rmofidian invitroevaluationofthewearofthreecompositeresins
_version_ 1718440264209530880