MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery

Background: Endolymphatic hydrops (EH) become visible in vertigo patients, particularly in those with Meniere's disease (MD), in vivo using gadolinium-enhanced MRI. However, the image quality is not satisfying after intravenous injection of gadolinium chelate (GdC), and occasional failure in Gd...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jing Zou, Zhen Wang, Yukun Chen, Guoping Zhang, Luguang Chen, Jianping Lu
Formato: article
Lenguaje:EN
Publicado: KeAi Communications Co., Ltd. 2019
Materias:
Acceso en línea:https://doaj.org/article/235852c0d57f4792b04975b4b1933061
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:235852c0d57f4792b04975b4b1933061
record_format dspace
spelling oai:doaj.org-article:235852c0d57f4792b04975b4b19330612021-12-02T14:12:06ZMRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery2095-881110.1016/j.wjorl.2019.04.001https://doaj.org/article/235852c0d57f4792b04975b4b19330612019-12-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2095881119301040https://doaj.org/toc/2095-8811Background: Endolymphatic hydrops (EH) become visible in vertigo patients, particularly in those with Meniere's disease (MD), in vivo using gadolinium-enhanced MRI. However, the image quality is not satisfying after intravenous injection of gadolinium chelate (GdC), and occasional failure in GdC uptake has been noticed after traditional intratympanic injection. In the present report, targeted delivery of GdC and using a cost-effective MRI system to obtain high quality images of EH in only 8 min will be introduced. Methods: 39 MD patients were recruited in the study. First, 0.1 ml of 20-fold diluted gadolinium-diethylenetriamine acid (Gd-DTPA) was delivered onto the posterior upper part of the tympanic medial wall using a soft-tipped micro-irrigation catheter through an artificially perforated tympanic membrane. Inner ear MRI was performed 24 h after Gd-DTPA administration using a 3T MR machine and a 20-channel head/neck coil with an 8 min sequence of medium inversion time inversion recovery imaging with magnitude reconstruction (MIIRMR). The parameters were as follows: TR 16000 ms, TE 663 ms, inversion time 2700 ms, flip angle 180°, slices per slab 60. Results: Efficient inner ear uptake of Gd-DTPA was detected 24 h after delivery and it created excellent contrast in the inner ear of all cases. High quality images demonstrating EH in the vestibule and cochlea were obtained. Conclusion: Targeted delivery of minimum Gd-DTPA (0.1 ml, 20-fold dilution) onto the posterior upper portion of the tympanic medial wall and MRI with MIIRMR in a 3T machine and 20-channel head/neck coil are clinically practical to obtain high quality images displaying EH. Keywords: Meniere's disease, Endolymphatic hydrops, MRI, Drug delivery, TargetingJing ZouZhen WangYukun ChenGuoping ZhangLuguang ChenJianping LuKeAi Communications Co., Ltd.articleOtorhinolaryngologyRF1-547SurgeryRD1-811ENWorld Journal of Otorhinolaryngology-Head and Neck Surgery, Vol 5, Iss 4, Pp 180-187 (2019)
institution DOAJ
collection DOAJ
language EN
topic Otorhinolaryngology
RF1-547
Surgery
RD1-811
spellingShingle Otorhinolaryngology
RF1-547
Surgery
RD1-811
Jing Zou
Zhen Wang
Yukun Chen
Guoping Zhang
Luguang Chen
Jianping Lu
MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery
description Background: Endolymphatic hydrops (EH) become visible in vertigo patients, particularly in those with Meniere's disease (MD), in vivo using gadolinium-enhanced MRI. However, the image quality is not satisfying after intravenous injection of gadolinium chelate (GdC), and occasional failure in GdC uptake has been noticed after traditional intratympanic injection. In the present report, targeted delivery of GdC and using a cost-effective MRI system to obtain high quality images of EH in only 8 min will be introduced. Methods: 39 MD patients were recruited in the study. First, 0.1 ml of 20-fold diluted gadolinium-diethylenetriamine acid (Gd-DTPA) was delivered onto the posterior upper part of the tympanic medial wall using a soft-tipped micro-irrigation catheter through an artificially perforated tympanic membrane. Inner ear MRI was performed 24 h after Gd-DTPA administration using a 3T MR machine and a 20-channel head/neck coil with an 8 min sequence of medium inversion time inversion recovery imaging with magnitude reconstruction (MIIRMR). The parameters were as follows: TR 16000 ms, TE 663 ms, inversion time 2700 ms, flip angle 180°, slices per slab 60. Results: Efficient inner ear uptake of Gd-DTPA was detected 24 h after delivery and it created excellent contrast in the inner ear of all cases. High quality images demonstrating EH in the vestibule and cochlea were obtained. Conclusion: Targeted delivery of minimum Gd-DTPA (0.1 ml, 20-fold dilution) onto the posterior upper portion of the tympanic medial wall and MRI with MIIRMR in a 3T machine and 20-channel head/neck coil are clinically practical to obtain high quality images displaying EH. Keywords: Meniere's disease, Endolymphatic hydrops, MRI, Drug delivery, Targeting
format article
author Jing Zou
Zhen Wang
Yukun Chen
Guoping Zhang
Luguang Chen
Jianping Lu
author_facet Jing Zou
Zhen Wang
Yukun Chen
Guoping Zhang
Luguang Chen
Jianping Lu
author_sort Jing Zou
title MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery
title_short MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery
title_full MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery
title_fullStr MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery
title_full_unstemmed MRI detection of endolymphatic hydrops in Meniere's disease in 8 minutes using MIIRMR and a 20-channel coil after targeted gadolinium delivery
title_sort mri detection of endolymphatic hydrops in meniere's disease in 8 minutes using miirmr and a 20-channel coil after targeted gadolinium delivery
publisher KeAi Communications Co., Ltd.
publishDate 2019
url https://doaj.org/article/235852c0d57f4792b04975b4b1933061
work_keys_str_mv AT jingzou mridetectionofendolymphatichydropsinmenieresdiseasein8minutesusingmiirmranda20channelcoilaftertargetedgadoliniumdelivery
AT zhenwang mridetectionofendolymphatichydropsinmenieresdiseasein8minutesusingmiirmranda20channelcoilaftertargetedgadoliniumdelivery
AT yukunchen mridetectionofendolymphatichydropsinmenieresdiseasein8minutesusingmiirmranda20channelcoilaftertargetedgadoliniumdelivery
AT guopingzhang mridetectionofendolymphatichydropsinmenieresdiseasein8minutesusingmiirmranda20channelcoilaftertargetedgadoliniumdelivery
AT luguangchen mridetectionofendolymphatichydropsinmenieresdiseasein8minutesusingmiirmranda20channelcoilaftertargetedgadoliniumdelivery
AT jianpinglu mridetectionofendolymphatichydropsinmenieresdiseasein8minutesusingmiirmranda20channelcoilaftertargetedgadoliniumdelivery
_version_ 1718391831288348672