Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information

Because the distributed power supply is connected to the distribution network, its structure has also changed the original traditional method. The original single power supply method was originally used. The network provided is a radial network and it is connected to the distributed power supply. La...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Shijie Cui, Peng Zeng, Zhongfeng Wang, Yue Zuo
Formato: article
Lenguaje:EN
Publicado: Hindawi Limited 2021
Materias:
Acceso en línea:https://doaj.org/article/23829e4e215b442ab8a1e9e46c3ab92d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:23829e4e215b442ab8a1e9e46c3ab92d
record_format dspace
spelling oai:doaj.org-article:23829e4e215b442ab8a1e9e46c3ab92d2021-11-22T01:10:52ZAdaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information1875-905X10.1155/2021/5137749https://doaj.org/article/23829e4e215b442ab8a1e9e46c3ab92d2021-01-01T00:00:00Zhttp://dx.doi.org/10.1155/2021/5137749https://doaj.org/toc/1875-905XBecause the distributed power supply is connected to the distribution network, its structure has also changed the original traditional method. The original single power supply method was originally used. The network provided is a radial network and it is connected to the distributed power supply. Later, it became a structure with small- and medium-sized power supplies inside, and its network power supply became dual or multiple power supplies. Such a structural change affected the coordination of power distribution protection devices, which would impose current on the distribution network. Protection has a negative impact. This paper aims to study the adaptive current protection technology of distribution network with distributed power based on local information. On the basis of analyzing the characteristics of distributed power, the classification of distributed power, and the operation mode of distributed power, according to the access of IIDG, as well as different influences of relay protection of distribution network, an improved protection scheme with adaptive current quick-break protection as the main protection is proposed, so that different fault characteristics of the distribution network have different setting values, and then simulation experiments are carried out on this scheme. The experimental results show that the setting value of three-phase short-circuit fault proposed in this paper can well protect the protection range, which is larger than the traditional protection setting and self-adaptive setting.Shijie CuiPeng ZengZhongfeng WangYue ZuoHindawi LimitedarticleTelecommunicationTK5101-6720ENMobile Information Systems, Vol 2021 (2021)
institution DOAJ
collection DOAJ
language EN
topic Telecommunication
TK5101-6720
spellingShingle Telecommunication
TK5101-6720
Shijie Cui
Peng Zeng
Zhongfeng Wang
Yue Zuo
Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information
description Because the distributed power supply is connected to the distribution network, its structure has also changed the original traditional method. The original single power supply method was originally used. The network provided is a radial network and it is connected to the distributed power supply. Later, it became a structure with small- and medium-sized power supplies inside, and its network power supply became dual or multiple power supplies. Such a structural change affected the coordination of power distribution protection devices, which would impose current on the distribution network. Protection has a negative impact. This paper aims to study the adaptive current protection technology of distribution network with distributed power based on local information. On the basis of analyzing the characteristics of distributed power, the classification of distributed power, and the operation mode of distributed power, according to the access of IIDG, as well as different influences of relay protection of distribution network, an improved protection scheme with adaptive current quick-break protection as the main protection is proposed, so that different fault characteristics of the distribution network have different setting values, and then simulation experiments are carried out on this scheme. The experimental results show that the setting value of three-phase short-circuit fault proposed in this paper can well protect the protection range, which is larger than the traditional protection setting and self-adaptive setting.
format article
author Shijie Cui
Peng Zeng
Zhongfeng Wang
Yue Zuo
author_facet Shijie Cui
Peng Zeng
Zhongfeng Wang
Yue Zuo
author_sort Shijie Cui
title Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information
title_short Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information
title_full Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information
title_fullStr Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information
title_full_unstemmed Adaptive Current Protection Technology for Distribution Network with Distributed Power Sources Based on Local Information
title_sort adaptive current protection technology for distribution network with distributed power sources based on local information
publisher Hindawi Limited
publishDate 2021
url https://doaj.org/article/23829e4e215b442ab8a1e9e46c3ab92d
work_keys_str_mv AT shijiecui adaptivecurrentprotectiontechnologyfordistributionnetworkwithdistributedpowersourcesbasedonlocalinformation
AT pengzeng adaptivecurrentprotectiontechnologyfordistributionnetworkwithdistributedpowersourcesbasedonlocalinformation
AT zhongfengwang adaptivecurrentprotectiontechnologyfordistributionnetworkwithdistributedpowersourcesbasedonlocalinformation
AT yuezuo adaptivecurrentprotectiontechnologyfordistributionnetworkwithdistributedpowersourcesbasedonlocalinformation
_version_ 1718418327100981248