Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method
Pharmacokinetics studies of domperidone generally analyze plasma matrix samples. The present work aimed to develop and validate a rapid and simple reversed phase-HPLC method for quantifying domperidone in plasma matrices. The chromatographic method implemented: 1. Luna Phenomenex® C18 (250 mm × 4.6...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Department of Chemistry, Universitas Gadjah Mada
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2389c520e6f04a299f8a3bf9d0519868 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:2389c520e6f04a299f8a3bf9d0519868 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2389c520e6f04a299f8a3bf9d05198682021-12-02T18:02:38ZValidation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method1411-94202460-157810.22146/ijc.64253https://doaj.org/article/2389c520e6f04a299f8a3bf9d05198682021-08-01T00:00:00Zhttps://jurnal.ugm.ac.id/ijc/article/view/64253https://doaj.org/toc/1411-9420https://doaj.org/toc/2460-1578Pharmacokinetics studies of domperidone generally analyze plasma matrix samples. The present work aimed to develop and validate a rapid and simple reversed phase-HPLC method for quantifying domperidone in plasma matrices. The chromatographic method implemented: 1. Luna Phenomenex® C18 (250 mm × 4.6 mm i.d; 5 µm) column, 2. isocratic mobile phase mixture of phosphate buffer 0.02 M:acetonitrile (70:30, v/v) with a flow rate of 1 mL/min, 3. UV detection at 285 nm. Domperidone and propranolol hydrochloride (as internal standard) were extracted from the deproteinated plasma sample. The method linearity was 0.998 in the range concentration of 15–200 ng/mL. The percentage of accuracy error was between -8.49–4.31%, while the percentage coefficient variation of precision ranged between 5.11–14.24%. This proposed method was simple, rapid (separation time less than 10 min), and selective. The validation parameters responses satisfied the method's requirements to determine domperidone in a plasma sample.Sekar Ayu PawestriAkhmad Kharis NugrohoEndang LukitaningsihPurwantiningsih PurwantiningsihDepartment of Chemistry, Universitas Gadjah Madaarticledomperidonerp-hplcspiked plasmavalidationChemistryQD1-999ENIndonesian Journal of Chemistry, Vol 21, Iss 5, Pp 1180-1186 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
domperidone rp-hplc spiked plasma validation Chemistry QD1-999 |
spellingShingle |
domperidone rp-hplc spiked plasma validation Chemistry QD1-999 Sekar Ayu Pawestri Akhmad Kharis Nugroho Endang Lukitaningsih Purwantiningsih Purwantiningsih Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method |
description |
Pharmacokinetics studies of domperidone generally analyze plasma matrix samples. The present work aimed to develop and validate a rapid and simple reversed phase-HPLC method for quantifying domperidone in plasma matrices. The chromatographic method implemented: 1. Luna Phenomenex® C18 (250 mm × 4.6 mm i.d; 5 µm) column, 2. isocratic mobile phase mixture of phosphate buffer 0.02 M:acetonitrile (70:30, v/v) with a flow rate of 1 mL/min, 3. UV detection at 285 nm. Domperidone and propranolol hydrochloride (as internal standard) were extracted from the deproteinated plasma sample. The method linearity was 0.998 in the range concentration of 15–200 ng/mL. The percentage of accuracy error was between -8.49–4.31%, while the percentage coefficient variation of precision ranged between 5.11–14.24%. This proposed method was simple, rapid (separation time less than 10 min), and selective. The validation parameters responses satisfied the method's requirements to determine domperidone in a plasma sample. |
format |
article |
author |
Sekar Ayu Pawestri Akhmad Kharis Nugroho Endang Lukitaningsih Purwantiningsih Purwantiningsih |
author_facet |
Sekar Ayu Pawestri Akhmad Kharis Nugroho Endang Lukitaningsih Purwantiningsih Purwantiningsih |
author_sort |
Sekar Ayu Pawestri |
title |
Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method |
title_short |
Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method |
title_full |
Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method |
title_fullStr |
Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method |
title_full_unstemmed |
Validation and Quantification of Domperidone in Spiked Plasma Matrix Using Reversed Phase HPLC-UV Method |
title_sort |
validation and quantification of domperidone in spiked plasma matrix using reversed phase hplc-uv method |
publisher |
Department of Chemistry, Universitas Gadjah Mada |
publishDate |
2021 |
url |
https://doaj.org/article/2389c520e6f04a299f8a3bf9d0519868 |
work_keys_str_mv |
AT sekarayupawestri validationandquantificationofdomperidoneinspikedplasmamatrixusingreversedphasehplcuvmethod AT akhmadkharisnugroho validationandquantificationofdomperidoneinspikedplasmamatrixusingreversedphasehplcuvmethod AT endanglukitaningsih validationandquantificationofdomperidoneinspikedplasmamatrixusingreversedphasehplcuvmethod AT purwantiningsihpurwantiningsih validationandquantificationofdomperidoneinspikedplasmamatrixusingreversedphasehplcuvmethod |
_version_ |
1718378856770961408 |