A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital
This paper presents a robust algorithm for the assessment of risk priority for medical equipment based on the calculation of static and dynamic risk factors and Kohnen Self Organization Maps (SOM). Four risk parameters have been calculated for 345 medical devices in two general hospitals in Baghdad...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Al-Khwarizmi College of Engineering – University of Baghdad
2009
|
Materias: | |
Acceso en línea: | https://doaj.org/article/239ce342f64e49ff99ade56967ac3f3e |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:239ce342f64e49ff99ade56967ac3f3e |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:239ce342f64e49ff99ade56967ac3f3e2021-12-02T01:27:11ZA Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital1818-11712312-0789https://doaj.org/article/239ce342f64e49ff99ade56967ac3f3e2009-03-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/521https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 This paper presents a robust algorithm for the assessment of risk priority for medical equipment based on the calculation of static and dynamic risk factors and Kohnen Self Organization Maps (SOM). Four risk parameters have been calculated for 345 medical devices in two general hospitals in Baghdad. Static risk factor components (equipment function and physical risk) and dynamics risk components (maintenance requirements and risk points) have been calculated. These risk components are used as an input to the unsupervised Kohonen self organization maps. The accuracy of the network was found to be equal to 98% for the proposed system. We conclude that the proposed model gives fast and accurate assessment for risk priority and it works as promising tool for risk factor assessment for the service departments in large hospitals in Iraq. Ali Hussian Ali Al TimemyShetha K. AbidNebras H. GhaebAl-Khwarizmi College of Engineering – University of BaghdadarticleChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 5, Iss 1 (2009) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 Ali Hussian Ali Al Timemy Shetha K. Abid Nebras H. Ghaeb A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital |
description |
This paper presents a robust algorithm for the assessment of risk priority for medical equipment based on the calculation of static and dynamic risk factors and Kohnen Self Organization Maps (SOM). Four risk parameters have been calculated for 345 medical devices in two general hospitals in Baghdad. Static risk factor components (equipment function and physical risk) and dynamics risk components (maintenance requirements and risk points) have been calculated. These risk components are used as an input to the unsupervised Kohonen self organization maps. The accuracy of the network was found to be equal to 98% for the proposed system. We conclude that the proposed model gives fast and accurate assessment for risk priority and it works as promising tool for risk factor assessment for the service departments in large hospitals in Iraq.
|
format |
article |
author |
Ali Hussian Ali Al Timemy Shetha K. Abid Nebras H. Ghaeb |
author_facet |
Ali Hussian Ali Al Timemy Shetha K. Abid Nebras H. Ghaeb |
author_sort |
Ali Hussian Ali Al Timemy |
title |
A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital |
title_short |
A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital |
title_full |
A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital |
title_fullStr |
A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital |
title_full_unstemmed |
A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital |
title_sort |
proposed artificial intelligence algorithm for assessing of risk priority for medical equipment in iraqi hospital |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
publishDate |
2009 |
url |
https://doaj.org/article/239ce342f64e49ff99ade56967ac3f3e |
work_keys_str_mv |
AT alihussianalialtimemy aproposedartificialintelligencealgorithmforassessingofriskpriorityformedicalequipmentiniraqihospital AT shethakabid aproposedartificialintelligencealgorithmforassessingofriskpriorityformedicalequipmentiniraqihospital AT nebrashghaeb aproposedartificialintelligencealgorithmforassessingofriskpriorityformedicalequipmentiniraqihospital AT alihussianalialtimemy proposedartificialintelligencealgorithmforassessingofriskpriorityformedicalequipmentiniraqihospital AT shethakabid proposedartificialintelligencealgorithmforassessingofriskpriorityformedicalequipmentiniraqihospital AT nebrashghaeb proposedartificialintelligencealgorithmforassessingofriskpriorityformedicalequipmentiniraqihospital |
_version_ |
1718403061644263424 |