Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources

Detection of single nanoparticles or molecules often relies on the attachment of fluorescent labels. Here, the authors demonstrate trapping a single nanoparticle on a bowtie nanoantenna and monitoring via second harmonic generation from the particle.

Guardado en:
Detalles Bibliográficos
Autores principales: Seung Ju Yoon, Jungmin Lee, Sangyoon Han, Chang-Kyu Kim, Chi Won Ahn, Myung-Ki Kim, Yong-Hee Lee
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2018
Materias:
Q
Acceso en línea:https://doaj.org/article/249a1045db9e48d7ad798becba8a2edc
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:249a1045db9e48d7ad798becba8a2edc
record_format dspace
spelling oai:doaj.org-article:249a1045db9e48d7ad798becba8a2edc2021-12-02T15:33:58ZNon-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources10.1038/s41467-018-04689-52041-1723https://doaj.org/article/249a1045db9e48d7ad798becba8a2edc2018-06-01T00:00:00Zhttps://doi.org/10.1038/s41467-018-04689-5https://doaj.org/toc/2041-1723Detection of single nanoparticles or molecules often relies on the attachment of fluorescent labels. Here, the authors demonstrate trapping a single nanoparticle on a bowtie nanoantenna and monitoring via second harmonic generation from the particle.Seung Ju YoonJungmin LeeSangyoon HanChang-Kyu KimChi Won AhnMyung-Ki KimYong-Hee LeeNature PortfolioarticleScienceQENNature Communications, Vol 9, Iss 1, Pp 1-8 (2018)
institution DOAJ
collection DOAJ
language EN
topic Science
Q
spellingShingle Science
Q
Seung Ju Yoon
Jungmin Lee
Sangyoon Han
Chang-Kyu Kim
Chi Won Ahn
Myung-Ki Kim
Yong-Hee Lee
Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
description Detection of single nanoparticles or molecules often relies on the attachment of fluorescent labels. Here, the authors demonstrate trapping a single nanoparticle on a bowtie nanoantenna and monitoring via second harmonic generation from the particle.
format article
author Seung Ju Yoon
Jungmin Lee
Sangyoon Han
Chang-Kyu Kim
Chi Won Ahn
Myung-Ki Kim
Yong-Hee Lee
author_facet Seung Ju Yoon
Jungmin Lee
Sangyoon Han
Chang-Kyu Kim
Chi Won Ahn
Myung-Ki Kim
Yong-Hee Lee
author_sort Seung Ju Yoon
title Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
title_short Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
title_full Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
title_fullStr Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
title_full_unstemmed Non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
title_sort non-fluorescent nanoscopic monitoring of a single trapped nanoparticle via nonlinear point sources
publisher Nature Portfolio
publishDate 2018
url https://doaj.org/article/249a1045db9e48d7ad798becba8a2edc
work_keys_str_mv AT seungjuyoon nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
AT jungminlee nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
AT sangyoonhan nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
AT changkyukim nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
AT chiwonahn nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
AT myungkikim nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
AT yongheelee nonfluorescentnanoscopicmonitoringofasingletrappednanoparticlevianonlinearpointsources
_version_ 1718386949591400448