The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision
Abstract We developed a new method to retrieve a dropped nucleus of the lens via a small incision using bipolar pencils, the kebab technique, to solve the lack of small-gauge fragmatomes, and the expense and toxicity of perfluorocarbon liquids (PFCL). A total of 8 eyes in 6 patients underwent this t...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/24eaae03cb714a1a96c86178579b7bcc |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:24eaae03cb714a1a96c86178579b7bcc |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:24eaae03cb714a1a96c86178579b7bcc2021-12-02T18:03:32ZThe kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision10.1038/s41598-021-87022-32045-2322https://doaj.org/article/24eaae03cb714a1a96c86178579b7bcc2021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87022-3https://doaj.org/toc/2045-2322Abstract We developed a new method to retrieve a dropped nucleus of the lens via a small incision using bipolar pencils, the kebab technique, to solve the lack of small-gauge fragmatomes, and the expense and toxicity of perfluorocarbon liquids (PFCL). A total of 8 eyes in 6 patients underwent this technique and were reviewed. After vitrectomy, the dropped nucleus of the lens was lifted from the retina by adhesion with a bipolar pencil, and phacoemulsification was performed while rotating the lens. The outcome measures were best-corrected visual acuity (BCVA), intraocular pressure (IOP), and corneal endothelial cell density before and after surgery. Surgical indications included zonular weakness, trauma, acute angle closure attack, and phacolytic glaucoma. At 1 month, BCVA improved from a mean (standard deviation, SD) 1.67 logMAR (0.90) to 1.14 logMAR (1.01). The mean preoperative IOP was 24.5 (16.8) mmHg and postoperative IOP was 11.0 (2.8) mmHg. The mean preoperative corneal endothelial cell count was 2600 (322) cells/mm2 (one eye was unmeasurable) and postoperative corneal endothelial cell count was 2387 (431) cells/mm2. There were no postoperative complications. The retrieval of a dropped nucleus of the lens using a bipolar pencil enables small incisions without using PFCL.Hiroshi AsoHarumasa YokotaHirotsugu HanazakiSatoru YamagamiTaiji NagaokaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-5 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Hiroshi Aso Harumasa Yokota Hirotsugu Hanazaki Satoru Yamagami Taiji Nagaoka The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
description |
Abstract We developed a new method to retrieve a dropped nucleus of the lens via a small incision using bipolar pencils, the kebab technique, to solve the lack of small-gauge fragmatomes, and the expense and toxicity of perfluorocarbon liquids (PFCL). A total of 8 eyes in 6 patients underwent this technique and were reviewed. After vitrectomy, the dropped nucleus of the lens was lifted from the retina by adhesion with a bipolar pencil, and phacoemulsification was performed while rotating the lens. The outcome measures were best-corrected visual acuity (BCVA), intraocular pressure (IOP), and corneal endothelial cell density before and after surgery. Surgical indications included zonular weakness, trauma, acute angle closure attack, and phacolytic glaucoma. At 1 month, BCVA improved from a mean (standard deviation, SD) 1.67 logMAR (0.90) to 1.14 logMAR (1.01). The mean preoperative IOP was 24.5 (16.8) mmHg and postoperative IOP was 11.0 (2.8) mmHg. The mean preoperative corneal endothelial cell count was 2600 (322) cells/mm2 (one eye was unmeasurable) and postoperative corneal endothelial cell count was 2387 (431) cells/mm2. There were no postoperative complications. The retrieval of a dropped nucleus of the lens using a bipolar pencil enables small incisions without using PFCL. |
format |
article |
author |
Hiroshi Aso Harumasa Yokota Hirotsugu Hanazaki Satoru Yamagami Taiji Nagaoka |
author_facet |
Hiroshi Aso Harumasa Yokota Hirotsugu Hanazaki Satoru Yamagami Taiji Nagaoka |
author_sort |
Hiroshi Aso |
title |
The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
title_short |
The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
title_full |
The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
title_fullStr |
The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
title_full_unstemmed |
The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
title_sort |
kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/24eaae03cb714a1a96c86178579b7bcc |
work_keys_str_mv |
AT hiroshiaso thekebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT harumasayokota thekebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT hirotsuguhanazaki thekebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT satoruyamagami thekebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT taijinagaoka thekebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT hiroshiaso kebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT harumasayokota kebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT hirotsuguhanazaki kebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT satoruyamagami kebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision AT taijinagaoka kebabtechniqueusesabipolarpenciltoretrieveadroppednucleusofthelensviaasmallincision |
_version_ |
1718378677004140544 |