Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors

Pre-insertion resistors (PIR) are critical components for suppressing the closing inrush current and operating overvoltage during the closing process of the circuit breaker. And it is widely adopted in 800kV and above transmission lines and alternating current filters of converter substations. These...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bo Niu, Feiyue Ma, Shangpeng Sun, Yuhua Xu
Formato: article
Lenguaje:EN
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://doaj.org/article/252ac79d5bf848d6a171801b16377506
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:252ac79d5bf848d6a171801b16377506
record_format dspace
spelling oai:doaj.org-article:252ac79d5bf848d6a171801b163775062021-11-26T04:34:18ZResearch on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors2352-484710.1016/j.egyr.2021.08.149https://doaj.org/article/252ac79d5bf848d6a171801b163775062021-11-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721007538https://doaj.org/toc/2352-4847Pre-insertion resistors (PIR) are critical components for suppressing the closing inrush current and operating overvoltage during the closing process of the circuit breaker. And it is widely adopted in 800kV and above transmission lines and alternating current filters of converter substations. These special application environments lead to higher failure rates than other electrical components. However, in the daily operation and fault diagnosis of PIR, there is no systematic method to analyze whether there are defects in PIR and the cause of failure after the PIR fails. Based on two PIR failure in series and parallel structures, this paper proposes methods such as dynamic resistance fitting, acoustic and vibration signal detection, insulation performance test, and heat capacity test during operation. In the aspect of fault diagnosis, methods such as PIR splicing based on Iterative Closest Point , stress analysis, and electric field simulation are proposed. Finally, proposed methods can be adjusted to estimate the operating state of PIR through the disassembly inspection to avoid the GIS breakdown accident during the operation of the circuit breaker.Bo NiuFeiyue MaShangpeng SunYuhua XuElsevierarticleSeries PIRShunt PIRSF6 circuit breakersOperation reliabilityFault diagnosisElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 7, Iss , Pp 38-47 (2021)
institution DOAJ
collection DOAJ
language EN
topic Series PIR
Shunt PIR
SF6 circuit breakers
Operation reliability
Fault diagnosis
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle Series PIR
Shunt PIR
SF6 circuit breakers
Operation reliability
Fault diagnosis
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Bo Niu
Feiyue Ma
Shangpeng Sun
Yuhua Xu
Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors
description Pre-insertion resistors (PIR) are critical components for suppressing the closing inrush current and operating overvoltage during the closing process of the circuit breaker. And it is widely adopted in 800kV and above transmission lines and alternating current filters of converter substations. These special application environments lead to higher failure rates than other electrical components. However, in the daily operation and fault diagnosis of PIR, there is no systematic method to analyze whether there are defects in PIR and the cause of failure after the PIR fails. Based on two PIR failure in series and parallel structures, this paper proposes methods such as dynamic resistance fitting, acoustic and vibration signal detection, insulation performance test, and heat capacity test during operation. In the aspect of fault diagnosis, methods such as PIR splicing based on Iterative Closest Point , stress analysis, and electric field simulation are proposed. Finally, proposed methods can be adjusted to estimate the operating state of PIR through the disassembly inspection to avoid the GIS breakdown accident during the operation of the circuit breaker.
format article
author Bo Niu
Feiyue Ma
Shangpeng Sun
Yuhua Xu
author_facet Bo Niu
Feiyue Ma
Shangpeng Sun
Yuhua Xu
author_sort Bo Niu
title Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors
title_short Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors
title_full Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors
title_fullStr Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors
title_full_unstemmed Research on operation and fault diagnosis technology for EHV/UHV SF6 circuit breakers pre-insertion resistors
title_sort research on operation and fault diagnosis technology for ehv/uhv sf6 circuit breakers pre-insertion resistors
publisher Elsevier
publishDate 2021
url https://doaj.org/article/252ac79d5bf848d6a171801b16377506
work_keys_str_mv AT boniu researchonoperationandfaultdiagnosistechnologyforehvuhvsf6circuitbreakerspreinsertionresistors
AT feiyuema researchonoperationandfaultdiagnosistechnologyforehvuhvsf6circuitbreakerspreinsertionresistors
AT shangpengsun researchonoperationandfaultdiagnosistechnologyforehvuhvsf6circuitbreakerspreinsertionresistors
AT yuhuaxu researchonoperationandfaultdiagnosistechnologyforehvuhvsf6circuitbreakerspreinsertionresistors
_version_ 1718409829051006976