Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients

Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Erald Duzha,2 Maria Tzinava,2 Asli Perente,1 Aristeidis Konstantinidis,1 Konstantinos Delibasis2 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biom...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Labiris G, Panagiotopoulou EK, Duzha E, Tzinava M, Perente A, Konstantinidis A, Delibasis K
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/252dee5a5d0a4f789d93810e61af4063
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:252dee5a5d0a4f789d93810e61af4063
record_format dspace
spelling oai:doaj.org-article:252dee5a5d0a4f789d93810e61af40632021-12-02T17:40:32ZDevelopment and Validation of a Web-Based Reading Test for Normal and Low Vision Patients1177-5483https://doaj.org/article/252dee5a5d0a4f789d93810e61af40632021-09-01T00:00:00Zhttps://www.dovepress.com/development-and-validation-of-a-web-based-reading-test-for-normal-and--peer-reviewed-fulltext-article-OPTHhttps://doaj.org/toc/1177-5483Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Erald Duzha,2 Maria Tzinava,2 Asli Perente,1 Aristeidis Konstantinidis,1 Konstantinos Delibasis2 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, 35131, GreeceCorrespondence: Georgios LabirisDepartment of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, GreeceTel +30 697 745 5027Fax +30 255 103 0405Email labiris@usa.netPurpose: To develop and validate a web-based reading test for normal and low vision patients.Methods: This is a prospective, comparative trial. The web-based Democritus Digital Acuity Reading Test (wDDART) was developed. wDDART introduces a series of advanced characteristics (advanced text calibration, computer-vision-based estimation of patient’s distance, and automatic calculation of patient’s reading times) that facilitate the overall examination procedure. wDDART’s reading parameters [reading acuity (RA), maximum reading speed (MRS), critical print size (CPS) and reading accessibility index (ACC)] were compared to the corresponding ones of its conventional Windows-based reading test (DDART) in a sample of normal and low vision participants. wDDART’s test–retest reliability for all reading parameters was evaluated in a 15-day time-window.Results: One hundred patients (normal vision group-NVG: 70; low vision group-LVG: 30 patients) responded to DDART and wDDART. Non-significant differences between the two reading tests were found for all parameters in NVG and LVG. Intraclass correlation coefficients (ICCs) between the two tests demonstrated good or excellent correlation for RA, MRS, ACC and moderate correlation for CPS. Test–retest reliability was excellent for RA and ACC, while ICCs were 0.715– 0.895 for MRS and CPS.Conclusion: The wDDART demonstrated sufficient validity and repeatability making it suitable for clinical and research settings.Clinicaltrials.gov Identifier: NCT04618224.Keywords: presbyopia, reading speed, critical print size, reading acuity, computer vision distance estimation, automatic reading timing, internet, readingLabiris GPanagiotopoulou EKDuzha ETzinava MPerente AKonstantinidis ADelibasis KDove Medical Pressarticlepresbyopiareading speedcritical print sizereading acuitycomputer vision distance estimationautomatic reading timinginternetreadingOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 15, Pp 3915-3929 (2021)
institution DOAJ
collection DOAJ
language EN
topic presbyopia
reading speed
critical print size
reading acuity
computer vision distance estimation
automatic reading timing
internet
reading
Ophthalmology
RE1-994
spellingShingle presbyopia
reading speed
critical print size
reading acuity
computer vision distance estimation
automatic reading timing
internet
reading
Ophthalmology
RE1-994
Labiris G
Panagiotopoulou EK
Duzha E
Tzinava M
Perente A
Konstantinidis A
Delibasis K
Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
description Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Erald Duzha,2 Maria Tzinava,2 Asli Perente,1 Aristeidis Konstantinidis,1 Konstantinos Delibasis2 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, 35131, GreeceCorrespondence: Georgios LabirisDepartment of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, GreeceTel +30 697 745 5027Fax +30 255 103 0405Email labiris@usa.netPurpose: To develop and validate a web-based reading test for normal and low vision patients.Methods: This is a prospective, comparative trial. The web-based Democritus Digital Acuity Reading Test (wDDART) was developed. wDDART introduces a series of advanced characteristics (advanced text calibration, computer-vision-based estimation of patient’s distance, and automatic calculation of patient’s reading times) that facilitate the overall examination procedure. wDDART’s reading parameters [reading acuity (RA), maximum reading speed (MRS), critical print size (CPS) and reading accessibility index (ACC)] were compared to the corresponding ones of its conventional Windows-based reading test (DDART) in a sample of normal and low vision participants. wDDART’s test–retest reliability for all reading parameters was evaluated in a 15-day time-window.Results: One hundred patients (normal vision group-NVG: 70; low vision group-LVG: 30 patients) responded to DDART and wDDART. Non-significant differences between the two reading tests were found for all parameters in NVG and LVG. Intraclass correlation coefficients (ICCs) between the two tests demonstrated good or excellent correlation for RA, MRS, ACC and moderate correlation for CPS. Test–retest reliability was excellent for RA and ACC, while ICCs were 0.715– 0.895 for MRS and CPS.Conclusion: The wDDART demonstrated sufficient validity and repeatability making it suitable for clinical and research settings.Clinicaltrials.gov Identifier: NCT04618224.Keywords: presbyopia, reading speed, critical print size, reading acuity, computer vision distance estimation, automatic reading timing, internet, reading
format article
author Labiris G
Panagiotopoulou EK
Duzha E
Tzinava M
Perente A
Konstantinidis A
Delibasis K
author_facet Labiris G
Panagiotopoulou EK
Duzha E
Tzinava M
Perente A
Konstantinidis A
Delibasis K
author_sort Labiris G
title Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
title_short Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
title_full Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
title_fullStr Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
title_full_unstemmed Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
title_sort development and validation of a web-based reading test for normal and low vision patients
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/252dee5a5d0a4f789d93810e61af4063
work_keys_str_mv AT labirisg developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
AT panagiotopoulouek developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
AT duzhae developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
AT tzinavam developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
AT perentea developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
AT konstantinidisa developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
AT delibasisk developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients
_version_ 1718379751401324544