Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients
Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Erald Duzha,2 Maria Tzinava,2 Asli Perente,1 Aristeidis Konstantinidis,1 Konstantinos Delibasis2 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biom...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/252dee5a5d0a4f789d93810e61af4063 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:252dee5a5d0a4f789d93810e61af4063 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:252dee5a5d0a4f789d93810e61af40632021-12-02T17:40:32ZDevelopment and Validation of a Web-Based Reading Test for Normal and Low Vision Patients1177-5483https://doaj.org/article/252dee5a5d0a4f789d93810e61af40632021-09-01T00:00:00Zhttps://www.dovepress.com/development-and-validation-of-a-web-based-reading-test-for-normal-and--peer-reviewed-fulltext-article-OPTHhttps://doaj.org/toc/1177-5483Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Erald Duzha,2 Maria Tzinava,2 Asli Perente,1 Aristeidis Konstantinidis,1 Konstantinos Delibasis2 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, 35131, GreeceCorrespondence: Georgios LabirisDepartment of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, GreeceTel +30 697 745 5027Fax +30 255 103 0405Email labiris@usa.netPurpose: To develop and validate a web-based reading test for normal and low vision patients.Methods: This is a prospective, comparative trial. The web-based Democritus Digital Acuity Reading Test (wDDART) was developed. wDDART introduces a series of advanced characteristics (advanced text calibration, computer-vision-based estimation of patient’s distance, and automatic calculation of patient’s reading times) that facilitate the overall examination procedure. wDDART’s reading parameters [reading acuity (RA), maximum reading speed (MRS), critical print size (CPS) and reading accessibility index (ACC)] were compared to the corresponding ones of its conventional Windows-based reading test (DDART) in a sample of normal and low vision participants. wDDART’s test–retest reliability for all reading parameters was evaluated in a 15-day time-window.Results: One hundred patients (normal vision group-NVG: 70; low vision group-LVG: 30 patients) responded to DDART and wDDART. Non-significant differences between the two reading tests were found for all parameters in NVG and LVG. Intraclass correlation coefficients (ICCs) between the two tests demonstrated good or excellent correlation for RA, MRS, ACC and moderate correlation for CPS. Test–retest reliability was excellent for RA and ACC, while ICCs were 0.715– 0.895 for MRS and CPS.Conclusion: The wDDART demonstrated sufficient validity and repeatability making it suitable for clinical and research settings.Clinicaltrials.gov Identifier: NCT04618224.Keywords: presbyopia, reading speed, critical print size, reading acuity, computer vision distance estimation, automatic reading timing, internet, readingLabiris GPanagiotopoulou EKDuzha ETzinava MPerente AKonstantinidis ADelibasis KDove Medical Pressarticlepresbyopiareading speedcritical print sizereading acuitycomputer vision distance estimationautomatic reading timinginternetreadingOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 15, Pp 3915-3929 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
presbyopia reading speed critical print size reading acuity computer vision distance estimation automatic reading timing internet reading Ophthalmology RE1-994 |
spellingShingle |
presbyopia reading speed critical print size reading acuity computer vision distance estimation automatic reading timing internet reading Ophthalmology RE1-994 Labiris G Panagiotopoulou EK Duzha E Tzinava M Perente A Konstantinidis A Delibasis K Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients |
description |
Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Erald Duzha,2 Maria Tzinava,2 Asli Perente,1 Aristeidis Konstantinidis,1 Konstantinos Delibasis2 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, 35131, GreeceCorrespondence: Georgios LabirisDepartment of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, GreeceTel +30 697 745 5027Fax +30 255 103 0405Email labiris@usa.netPurpose: To develop and validate a web-based reading test for normal and low vision patients.Methods: This is a prospective, comparative trial. The web-based Democritus Digital Acuity Reading Test (wDDART) was developed. wDDART introduces a series of advanced characteristics (advanced text calibration, computer-vision-based estimation of patient’s distance, and automatic calculation of patient’s reading times) that facilitate the overall examination procedure. wDDART’s reading parameters [reading acuity (RA), maximum reading speed (MRS), critical print size (CPS) and reading accessibility index (ACC)] were compared to the corresponding ones of its conventional Windows-based reading test (DDART) in a sample of normal and low vision participants. wDDART’s test–retest reliability for all reading parameters was evaluated in a 15-day time-window.Results: One hundred patients (normal vision group-NVG: 70; low vision group-LVG: 30 patients) responded to DDART and wDDART. Non-significant differences between the two reading tests were found for all parameters in NVG and LVG. Intraclass correlation coefficients (ICCs) between the two tests demonstrated good or excellent correlation for RA, MRS, ACC and moderate correlation for CPS. Test–retest reliability was excellent for RA and ACC, while ICCs were 0.715– 0.895 for MRS and CPS.Conclusion: The wDDART demonstrated sufficient validity and repeatability making it suitable for clinical and research settings.Clinicaltrials.gov Identifier: NCT04618224.Keywords: presbyopia, reading speed, critical print size, reading acuity, computer vision distance estimation, automatic reading timing, internet, reading |
format |
article |
author |
Labiris G Panagiotopoulou EK Duzha E Tzinava M Perente A Konstantinidis A Delibasis K |
author_facet |
Labiris G Panagiotopoulou EK Duzha E Tzinava M Perente A Konstantinidis A Delibasis K |
author_sort |
Labiris G |
title |
Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients |
title_short |
Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients |
title_full |
Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients |
title_fullStr |
Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients |
title_full_unstemmed |
Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients |
title_sort |
development and validation of a web-based reading test for normal and low vision patients |
publisher |
Dove Medical Press |
publishDate |
2021 |
url |
https://doaj.org/article/252dee5a5d0a4f789d93810e61af4063 |
work_keys_str_mv |
AT labirisg developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients AT panagiotopoulouek developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients AT duzhae developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients AT tzinavam developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients AT perentea developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients AT konstantinidisa developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients AT delibasisk developmentandvalidationofawebbasedreadingtestfornormalandlowvisionpatients |
_version_ |
1718379751401324544 |