Single-phase grounding fault line selection method based on zero-sequence current increment
To address single-phase grounding fault line selection problem in small current grounding distribution network, the paper proposes a fault line selection method based on zero-sequence current (ZSC) increment. The method downshift grounding transformer (GT) tap step-by-step to amplify fault current,...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://doaj.org/article/25cdec254bb540bd8324a8bfe44cfdad |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:25cdec254bb540bd8324a8bfe44cfdad |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:25cdec254bb540bd8324a8bfe44cfdad2021-12-04T04:35:13ZSingle-phase grounding fault line selection method based on zero-sequence current increment2352-484710.1016/j.egyr.2021.11.196https://doaj.org/article/25cdec254bb540bd8324a8bfe44cfdad2022-04-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2352484721013391https://doaj.org/toc/2352-4847To address single-phase grounding fault line selection problem in small current grounding distribution network, the paper proposes a fault line selection method based on zero-sequence current (ZSC) increment. The method downshift grounding transformer (GT) tap step-by-step to amplify fault current, defines the line with largest ZSC variation as fault line. The results of typical non-effectively grounding 10 kV distribution network show the rationality and applicability of the proposed method.Bai HaoElsevierarticleFault line selectionZero-sequence currentDistribution networkTransformerElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENEnergy Reports, Vol 8, Iss , Pp 305-312 (2022) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Fault line selection Zero-sequence current Distribution network Transformer Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
Fault line selection Zero-sequence current Distribution network Transformer Electrical engineering. Electronics. Nuclear engineering TK1-9971 Bai Hao Single-phase grounding fault line selection method based on zero-sequence current increment |
description |
To address single-phase grounding fault line selection problem in small current grounding distribution network, the paper proposes a fault line selection method based on zero-sequence current (ZSC) increment. The method downshift grounding transformer (GT) tap step-by-step to amplify fault current, defines the line with largest ZSC variation as fault line. The results of typical non-effectively grounding 10 kV distribution network show the rationality and applicability of the proposed method. |
format |
article |
author |
Bai Hao |
author_facet |
Bai Hao |
author_sort |
Bai Hao |
title |
Single-phase grounding fault line selection method based on zero-sequence current increment |
title_short |
Single-phase grounding fault line selection method based on zero-sequence current increment |
title_full |
Single-phase grounding fault line selection method based on zero-sequence current increment |
title_fullStr |
Single-phase grounding fault line selection method based on zero-sequence current increment |
title_full_unstemmed |
Single-phase grounding fault line selection method based on zero-sequence current increment |
title_sort |
single-phase grounding fault line selection method based on zero-sequence current increment |
publisher |
Elsevier |
publishDate |
2022 |
url |
https://doaj.org/article/25cdec254bb540bd8324a8bfe44cfdad |
work_keys_str_mv |
AT baihao singlephasegroundingfaultlineselectionmethodbasedonzerosequencecurrentincrement |
_version_ |
1718372899697459200 |