Development of a colonoscopy add-on device for improvement of the intubation process

Jonathan D Litten1, JungHun Choi2, David Drozek31Department of Mechanical Engineering; 2Department of Mechanical Engineering and Biomedical Engineering Program; 3College of Osteopathic Medicine, Department of Specialty Medicine, Ohio University, Athens, OH, USAAbstract: A colonoscopy add-on device h...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Litten JD, Choi JH, Drozek D
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://doaj.org/article/25d6d4a87bcd4ddd85fa7bc8a1547dde
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:25d6d4a87bcd4ddd85fa7bc8a1547dde
record_format dspace
spelling oai:doaj.org-article:25d6d4a87bcd4ddd85fa7bc8a1547dde2021-12-02T01:20:41ZDevelopment of a colonoscopy add-on device for improvement of the intubation process1179-1470https://doaj.org/article/25d6d4a87bcd4ddd85fa7bc8a1547dde2011-12-01T00:00:00Zhttp://www.dovepress.com/development-of-a-colonoscopy-add-on-device-for-improvement-of-the-intu-a8894https://doaj.org/toc/1179-1470Jonathan D Litten1, JungHun Choi2, David Drozek31Department of Mechanical Engineering; 2Department of Mechanical Engineering and Biomedical Engineering Program; 3College of Osteopathic Medicine, Department of Specialty Medicine, Ohio University, Athens, OH, USAAbstract: A colonoscopy add-on device has been developed to reduce intubation time without modification of the current colonoscope and peripheral devices. One of the main purposes of the system is to minimize trauma caused by the distal tip of the colonoscope. The detachable sensory fixture at the end of the distal tip measures the distance between the distal tip and the colon wall in three directions, and the actuation system attached at the base of the colonoscope controls the distal tip by rotating two dial knobs. The device controls the distal tip to minimize contact between the distal tip and the colon wall, and the distal tip ideally points out the next possible lumen. A compatibility test of the infrared sensory system was carried out, and the design of the actuation system was accomplished. The system is integrated and controlled by a microprocessor. The device was tested in a silicon colon and porcine intestine. The results showed that a colonoscopist successfully reached the cecum with the aid of the colonoscopy add-on device without significant contact between the colon wall and the distal tip. The colonoscopy aid device was very helpful for the novice colonoscopist.Keywords: colonoscope, infrared sensors, intubation, trauma, colonoscopy training modelLitten JDChoi JHDrozek DDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2011, Iss default, Pp 197-208 (2011)
institution DOAJ
collection DOAJ
language EN
topic Medical technology
R855-855.5
spellingShingle Medical technology
R855-855.5
Litten JD
Choi JH
Drozek D
Development of a colonoscopy add-on device for improvement of the intubation process
description Jonathan D Litten1, JungHun Choi2, David Drozek31Department of Mechanical Engineering; 2Department of Mechanical Engineering and Biomedical Engineering Program; 3College of Osteopathic Medicine, Department of Specialty Medicine, Ohio University, Athens, OH, USAAbstract: A colonoscopy add-on device has been developed to reduce intubation time without modification of the current colonoscope and peripheral devices. One of the main purposes of the system is to minimize trauma caused by the distal tip of the colonoscope. The detachable sensory fixture at the end of the distal tip measures the distance between the distal tip and the colon wall in three directions, and the actuation system attached at the base of the colonoscope controls the distal tip by rotating two dial knobs. The device controls the distal tip to minimize contact between the distal tip and the colon wall, and the distal tip ideally points out the next possible lumen. A compatibility test of the infrared sensory system was carried out, and the design of the actuation system was accomplished. The system is integrated and controlled by a microprocessor. The device was tested in a silicon colon and porcine intestine. The results showed that a colonoscopist successfully reached the cecum with the aid of the colonoscopy add-on device without significant contact between the colon wall and the distal tip. The colonoscopy aid device was very helpful for the novice colonoscopist.Keywords: colonoscope, infrared sensors, intubation, trauma, colonoscopy training model
format article
author Litten JD
Choi JH
Drozek D
author_facet Litten JD
Choi JH
Drozek D
author_sort Litten JD
title Development of a colonoscopy add-on device for improvement of the intubation process
title_short Development of a colonoscopy add-on device for improvement of the intubation process
title_full Development of a colonoscopy add-on device for improvement of the intubation process
title_fullStr Development of a colonoscopy add-on device for improvement of the intubation process
title_full_unstemmed Development of a colonoscopy add-on device for improvement of the intubation process
title_sort development of a colonoscopy add-on device for improvement of the intubation process
publisher Dove Medical Press
publishDate 2011
url https://doaj.org/article/25d6d4a87bcd4ddd85fa7bc8a1547dde
work_keys_str_mv AT littenjd developmentofacolonoscopyaddondeviceforimprovementoftheintubationprocess
AT choijh developmentofacolonoscopyaddondeviceforimprovementoftheintubationprocess
AT drozekd developmentofacolonoscopyaddondeviceforimprovementoftheintubationprocess
_version_ 1718403126949576704