Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector

In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jafar M. Hassan, Qussai J. Abdul-Ghafour, Mohammed F. Mohammed
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2015
Materias:
Acceso en línea:https://doaj.org/article/262aefb061094272b642cd668098ff62
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively.