Critically coupled Fabry–Perot cavity with high signal contrast for refractive index sensing
Abstract Perfect absorption at a resonance wavelength and extremely low absorption at the wavelength range of off-resonance in a one-port optical cavity is required for refractive index (RI) sensing with high signal contrast. Here, we propose and analyze an absorption-enhanced Fabry–Perot (MAFP) cav...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2761041af9d34f66997de7fb23147620 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | Abstract Perfect absorption at a resonance wavelength and extremely low absorption at the wavelength range of off-resonance in a one-port optical cavity is required for refractive index (RI) sensing with high signal contrast. Here, we propose and analyze an absorption-enhanced Fabry–Perot (MAFP) cavity based on a critical coupling condition in a near-infrared wavelength range. For a one-port cavity, a thick bottom Au is used as a mirror and an absorber. To achieve the critical coupling condition, a top dielectric metasurface is employed and tailored to balance the radiation coupling and the absorption coupling rates, and the one-port cavity is theoretically analyzed using temporal coupled-mode theory. We investigate two types of MAFP structures for gas and liquid. The gas MAFP cavity shows a sensitivity of ~ 1388 nm/RIU and a full-width at half-maximum of less than 0.7 nm. This MAFP cavity resolves the RI change of 5 × 10−4 with a reflectance signal margin of 50% and achieves a signal contrast of ~ 100%. The liquid MAFP cavity shows a sensitivity of ~ 996 nm/RIU when RI of liquid changes from 1.30 to 1.38. With tailoring the period of the metasurface maintaining its thickness, a signal contrast of ~ 100% is achieved for each specific RI range. |
---|