Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.

The objective of this study was to analyze the difference in residual setup errors between 6D ExacTrac and 3D cone-beam computed tomography (CBCT) image-guided systems in spinal stereotactic body radiation therapy (SBRT). We investigated 76 patients with spinal tumors who received SBRT using Novalis...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jaehyeon Park, Ji Woon Yea, Jae Won Park, Se An Oh
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/2782d7a1b1a14bd191b7ffeb3b629399
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2782d7a1b1a14bd191b7ffeb3b629399
record_format dspace
spelling oai:doaj.org-article:2782d7a1b1a14bd191b7ffeb3b6293992021-11-25T06:23:39ZEvaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.1932-620310.1371/journal.pone.0252234https://doaj.org/article/2782d7a1b1a14bd191b7ffeb3b6293992021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0252234https://doaj.org/toc/1932-6203The objective of this study was to analyze the difference in residual setup errors between 6D ExacTrac and 3D cone-beam computed tomography (CBCT) image-guided systems in spinal stereotactic body radiation therapy (SBRT). We investigated 76 patients with spinal tumors who received SBRT using Novalis Tx at our institution between January 2013 and September 2020. A Vac-lok (EZ-FIX®, Arlico Medical Company, South Korea) fixture and an assistive device, based on the region involved, were used to immobilize patients and to increase the inter-fractional setup reproducibility. The difference in the root mean square (RMS) between the 6D ExacTrac and 3D CBCT was -0.75 mm, 0.45 mm, 0.16 mm, and -0.03°; the RMS value was 1.31 mm, 1.06 mm, 0.87 mm, and 0.64°; and the standard deviation was 0.80 mm, 0.72 mm, 0.62 mm, and 0.44° for lateral, longitudinal, vertical, and yaw directions, respectively. The difference in the average RMS between ExacTrac and CBCT was <1.03 mm in the translation direction and <0.47° in the rotational direction; the results were statistically significant in the lateral, longitudinal, and vertical directions, but not in the yaw direction. Thus, it is necessary to verify the ExacTrac image according to the CBCT image.Jaehyeon ParkJi Woon YeaJae Won ParkSe An OhPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 5, p e0252234 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Jaehyeon Park
Ji Woon Yea
Jae Won Park
Se An Oh
Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.
description The objective of this study was to analyze the difference in residual setup errors between 6D ExacTrac and 3D cone-beam computed tomography (CBCT) image-guided systems in spinal stereotactic body radiation therapy (SBRT). We investigated 76 patients with spinal tumors who received SBRT using Novalis Tx at our institution between January 2013 and September 2020. A Vac-lok (EZ-FIX®, Arlico Medical Company, South Korea) fixture and an assistive device, based on the region involved, were used to immobilize patients and to increase the inter-fractional setup reproducibility. The difference in the root mean square (RMS) between the 6D ExacTrac and 3D CBCT was -0.75 mm, 0.45 mm, 0.16 mm, and -0.03°; the RMS value was 1.31 mm, 1.06 mm, 0.87 mm, and 0.64°; and the standard deviation was 0.80 mm, 0.72 mm, 0.62 mm, and 0.44° for lateral, longitudinal, vertical, and yaw directions, respectively. The difference in the average RMS between ExacTrac and CBCT was <1.03 mm in the translation direction and <0.47° in the rotational direction; the results were statistically significant in the lateral, longitudinal, and vertical directions, but not in the yaw direction. Thus, it is necessary to verify the ExacTrac image according to the CBCT image.
format article
author Jaehyeon Park
Ji Woon Yea
Jae Won Park
Se An Oh
author_facet Jaehyeon Park
Ji Woon Yea
Jae Won Park
Se An Oh
author_sort Jaehyeon Park
title Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.
title_short Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.
title_full Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.
title_fullStr Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.
title_full_unstemmed Evaluation of the setup discrepancy between 6D ExacTrac and cone beam computed tomography in spine stereotactic body radiation therapy.
title_sort evaluation of the setup discrepancy between 6d exactrac and cone beam computed tomography in spine stereotactic body radiation therapy.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/2782d7a1b1a14bd191b7ffeb3b629399
work_keys_str_mv AT jaehyeonpark evaluationofthesetupdiscrepancybetween6dexactracandconebeamcomputedtomographyinspinestereotacticbodyradiationtherapy
AT jiwoonyea evaluationofthesetupdiscrepancybetween6dexactracandconebeamcomputedtomographyinspinestereotacticbodyradiationtherapy
AT jaewonpark evaluationofthesetupdiscrepancybetween6dexactracandconebeamcomputedtomographyinspinestereotacticbodyradiationtherapy
AT seanoh evaluationofthesetupdiscrepancybetween6dexactracandconebeamcomputedtomographyinspinestereotacticbodyradiationtherapy
_version_ 1718413730115485696