A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging

Abstract To assess visibility and artifact characteristics of polymer fiducials compared to standard gold fiducials for radiotherapy CT and MRI simulation. Three gold and three polymer fiducials were inserted into a CT and MRI tissue-equivalent phantom that approximated the prostate cancer radiother...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Daryl Lim Joon, Drew Smith, Mark Tacey, Michal Schneider, Benjamin Harris, Wee Loon Ong, Farshad Foroudi, Trish Jenkins, Morikatsu Wada, Michael Chao, Kym Rykers, Vincent Khoo
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/27d91cb93f6b4b469fcdf7b576263ccb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:27d91cb93f6b4b469fcdf7b576263ccb
record_format dspace
spelling oai:doaj.org-article:27d91cb93f6b4b469fcdf7b576263ccb2021-12-02T16:55:53ZA phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging10.1038/s41598-021-88300-w2045-2322https://doaj.org/article/27d91cb93f6b4b469fcdf7b576263ccb2021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-88300-whttps://doaj.org/toc/2045-2322Abstract To assess visibility and artifact characteristics of polymer fiducials compared to standard gold fiducials for radiotherapy CT and MRI simulation. Three gold and three polymer fiducials were inserted into a CT and MRI tissue-equivalent phantom that approximated the prostate cancer radiotherapy configuration. The phantom and fiducials were imaged on CT and MRI. Images were assessed in terms of fiducial visibility and artifact. ImageJ was employed to quantify the pixel gray-scale of each fiducial and artifact. Fiducial gray-scale histograms and profiles were generated for analysis. Objective measurements of the contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and artifact index (AI) were calculated. The CT images showed that the gold fiducials are visually brighter, with greater contrast than the polymer. The higher peak values illustrate this in the line profiles. However, they produce bright radiating and dark shadowing artifacts. This is depicted by the greater width of line profiles and the disruption of phantom area profiles. Quantitatively this results in greater percentile ranges of the histograms. Furthermore, for CT, gold had a higher CNR than polymer, relative to the phantom. However, the gold CNR and SNR were degraded by the greater artifact and thus AI. Both fiducials were visible on MRI and had similar histograms and profiles that were also reflected in comparable CNR, SNR and AI. Polymer fiducials were well visualized in a phantom on CT and MR and produce less artifact than the gold fiducials. Polymer markers could enhance the quality and accuracy of radiotherapy co-registration and planning but require clinical confirmation.Daryl Lim JoonDrew SmithMark TaceyMichal SchneiderBenjamin HarrisWee Loon OngFarshad ForoudiTrish JenkinsMorikatsu WadaMichael ChaoKym RykersVincent KhooNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-10 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Daryl Lim Joon
Drew Smith
Mark Tacey
Michal Schneider
Benjamin Harris
Wee Loon Ong
Farshad Foroudi
Trish Jenkins
Morikatsu Wada
Michael Chao
Kym Rykers
Vincent Khoo
A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
description Abstract To assess visibility and artifact characteristics of polymer fiducials compared to standard gold fiducials for radiotherapy CT and MRI simulation. Three gold and three polymer fiducials were inserted into a CT and MRI tissue-equivalent phantom that approximated the prostate cancer radiotherapy configuration. The phantom and fiducials were imaged on CT and MRI. Images were assessed in terms of fiducial visibility and artifact. ImageJ was employed to quantify the pixel gray-scale of each fiducial and artifact. Fiducial gray-scale histograms and profiles were generated for analysis. Objective measurements of the contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and artifact index (AI) were calculated. The CT images showed that the gold fiducials are visually brighter, with greater contrast than the polymer. The higher peak values illustrate this in the line profiles. However, they produce bright radiating and dark shadowing artifacts. This is depicted by the greater width of line profiles and the disruption of phantom area profiles. Quantitatively this results in greater percentile ranges of the histograms. Furthermore, for CT, gold had a higher CNR than polymer, relative to the phantom. However, the gold CNR and SNR were degraded by the greater artifact and thus AI. Both fiducials were visible on MRI and had similar histograms and profiles that were also reflected in comparable CNR, SNR and AI. Polymer fiducials were well visualized in a phantom on CT and MR and produce less artifact than the gold fiducials. Polymer markers could enhance the quality and accuracy of radiotherapy co-registration and planning but require clinical confirmation.
format article
author Daryl Lim Joon
Drew Smith
Mark Tacey
Michal Schneider
Benjamin Harris
Wee Loon Ong
Farshad Foroudi
Trish Jenkins
Morikatsu Wada
Michael Chao
Kym Rykers
Vincent Khoo
author_facet Daryl Lim Joon
Drew Smith
Mark Tacey
Michal Schneider
Benjamin Harris
Wee Loon Ong
Farshad Foroudi
Trish Jenkins
Morikatsu Wada
Michael Chao
Kym Rykers
Vincent Khoo
author_sort Daryl Lim Joon
title A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
title_short A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
title_full A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
title_fullStr A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
title_full_unstemmed A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
title_sort phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/27d91cb93f6b4b469fcdf7b576263ccb
work_keys_str_mv AT daryllimjoon aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT drewsmith aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT marktacey aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT michalschneider aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT benjaminharris aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT weeloonong aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT farshadforoudi aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT trishjenkins aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT morikatsuwada aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT michaelchao aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT kymrykers aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT vincentkhoo aphantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT daryllimjoon phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT drewsmith phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT marktacey phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT michalschneider phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT benjaminharris phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT weeloonong phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT farshadforoudi phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT trishjenkins phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT morikatsuwada phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT michaelchao phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT kymrykers phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
AT vincentkhoo phantomstudytocontrastandcomparepolymerandgoldfiducialmarkersinradiotherapysimulationimaging
_version_ 1718382788640505856