Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation

Jeannette A Goudzwaard,1 Eleonora Disegna,1 Marjo JAG de Ronde-Tillmans,2 Mattie J Lenzen,2 Peter PT de Jaegere,2 Francesco US Mattace-Raso11Section of Geriatric Medicine, Department of Internal Medicine, Erasmus University Medical Center, Rotterdam, the Netherlands; 2Department of Interventional Ca...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Goudzwaard JA, Disegna E, de Ronde-Tillmans MJAG, Lenzen MJ, de Jaegere PPT, Mattace-Raso FUS
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/27eb14d0375c4f4e873e546468e2604f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Jeannette A Goudzwaard,1 Eleonora Disegna,1 Marjo JAG de Ronde-Tillmans,2 Mattie J Lenzen,2 Peter PT de Jaegere,2 Francesco US Mattace-Raso11Section of Geriatric Medicine, Department of Internal Medicine, Erasmus University Medical Center, Rotterdam, the Netherlands; 2Department of Interventional Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, the NetherlandsBackground: Both aortic valve stenosis and aortic stiffness are moderators of arterio ventricular coupling and independent predictors of cardiovascular morbidity and mortality. Studies on the effect of transcatheter aortic valve implantation (TAVI) on aortic functional properties are limited. We performed a study to investigate the possible short-term changes in aortic stiffness and other aortic functional properties after TAVI in older patients.Methods: TAVI Care&Cure is an observational ongoing study including consecutive patients undergoing a TAVI procedure. Central and peripheral hemodynamic measurements were measured non invasively 1 day before (T-1) and 1 day after (T+1) TAVI using a validated oscillometric method using a brachial cuff (Mobil-O-Graph).Results: 40 patients were included. Mean aortic valve area at baseline was 0.76±0.24 cm2. Indices of severity of aortic valve stenosis improved significantly. Systolic blood pressure (SBP) dropped by 8.5%, from 130.3±22.9 mmHg to 119.5±15.8 mmHg (p=0.005). Diastolic blood pressure (DBP) dropped by 13.1% from 74.8±14.5 mmHg to 65.0±11.3 mmHg (p<0.001). The arterial pulse wave velocity (aPWV) decreased from 12.05±1.99 m/s to 11.6±1.56 m/s (p=0.006). Patients with high aPWV at baseline showed a significantly larger reduction in SBP in comparison to patients with low aPWV: – 20.3 mmHg (−14.1%) vs – 3.1 mmHg (−2.6%), respectively (p=0.033). The same trend was found for the DBP: −16.2 (−20.4%) vs −4.5 mmHg (−6.3%) for high vs low aPWV at baseline (p=0.037).Conclusion: We found short-term changes in blood pressure and aortic stiffness after TAVI. The amplitude of the changes was the largest in patients with elevated aortic stiffness at baseline.Keywords: aortic valve stenosis, aortic stiffness, blood pressure levels, TAVI