Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor

A district heating system for household heating and road snow melting utilizing waste heat from Gas Turbine High-Temperature Reactors of 300 MW (GTHTR300s), a high-temperature gas-cooled reactor design, was analyzed. The application area was set in Sapporo and Ishikari, cities with heavy snowfall in...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Seiji KASAHARA, Tetsuya MURATA, Yu KAMIJI, Atsuhiko TERADA, Xing YAN, Yoshiyuki INAGAKI, Michitsugu MORI
Formato: article
Lenguaje:EN
Publicado: The Japan Society of Mechanical Engineers 2016
Materias:
Acceso en línea:https://doaj.org/article/28b49ea1d11143ecb608415518b08ff3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:28b49ea1d11143ecb608415518b08ff3
record_format dspace
spelling oai:doaj.org-article:28b49ea1d11143ecb608415518b08ff32021-11-26T06:51:30ZHeat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor2187-974510.1299/mej.15-00616https://doaj.org/article/28b49ea1d11143ecb608415518b08ff32016-03-01T00:00:00Zhttps://www.jstage.jst.go.jp/article/mej/3/3/3_15-00616/_pdf/-char/enhttps://doaj.org/toc/2187-9745A district heating system for household heating and road snow melting utilizing waste heat from Gas Turbine High-Temperature Reactors of 300 MW (GTHTR300s), a high-temperature gas-cooled reactor design, was analyzed. The application area was set in Sapporo and Ishikari, cities with heavy snowfall in northern Japan. The heat transport analyses were performed by modeling heat-transfer components in the system to estimate the system's overall heat supply profile. These components included the pipelines of the secondary water loops between the GTHTR300s and the heat-application area; heat exchangers to transfer the heat from the secondary loops to the tertiary water loops of the district-heating pipes; and the district-heating pipes of the tertiary loops between the heat exchangers and houses and roads. Single- and double-pipes for the secondary loops were compared. Although the double-pipes were advantageous for having less heat loss and a smaller excavation area, these advantages did not compensate for the higher construction cost of the pipes. To satisfy the heat demand of the application area in the month of maximum requirement, 520-529 MW of heat were supplied by 3 GTHTR300s and delivered by 6 secondary loops, 3,450 heat exchangers about 90 m long, and 3,450 tertiary loops. More efficient designs for the heat exchangers and improvements to the tertiary loops applying branched flow networks are desired to reduce the number of heat exchangers and tertiary loops and to make the heat exchangers smaller. Heat lost to the ground from the tertiary loops comprised 80%-90% of the heat loss. Applications of the larger pipe or loops using the branched flow network or double-pipe are required for more efficient heat utilization. More than 90% of the construction cost went into thermal insulators. The thickness and properties of the insulator must be reevaluated for economical heat delivery.Seiji KASAHARATetsuya MURATAYu KAMIJIAtsuhiko TERADAXing YANYoshiyuki INAGAKIMichitsugu MORIThe Japan Society of Mechanical Engineersarticlehigh-temperature gas-cooled reactorgthtr300waste heat applicationdistrict heatingheat-transfer modelingMechanical engineering and machineryTJ1-1570ENMechanical Engineering Journal, Vol 3, Iss 3, Pp 15-00616-15-00616 (2016)
institution DOAJ
collection DOAJ
language EN
topic high-temperature gas-cooled reactor
gthtr300
waste heat application
district heating
heat-transfer modeling
Mechanical engineering and machinery
TJ1-1570
spellingShingle high-temperature gas-cooled reactor
gthtr300
waste heat application
district heating
heat-transfer modeling
Mechanical engineering and machinery
TJ1-1570
Seiji KASAHARA
Tetsuya MURATA
Yu KAMIJI
Atsuhiko TERADA
Xing YAN
Yoshiyuki INAGAKI
Michitsugu MORI
Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor
description A district heating system for household heating and road snow melting utilizing waste heat from Gas Turbine High-Temperature Reactors of 300 MW (GTHTR300s), a high-temperature gas-cooled reactor design, was analyzed. The application area was set in Sapporo and Ishikari, cities with heavy snowfall in northern Japan. The heat transport analyses were performed by modeling heat-transfer components in the system to estimate the system's overall heat supply profile. These components included the pipelines of the secondary water loops between the GTHTR300s and the heat-application area; heat exchangers to transfer the heat from the secondary loops to the tertiary water loops of the district-heating pipes; and the district-heating pipes of the tertiary loops between the heat exchangers and houses and roads. Single- and double-pipes for the secondary loops were compared. Although the double-pipes were advantageous for having less heat loss and a smaller excavation area, these advantages did not compensate for the higher construction cost of the pipes. To satisfy the heat demand of the application area in the month of maximum requirement, 520-529 MW of heat were supplied by 3 GTHTR300s and delivered by 6 secondary loops, 3,450 heat exchangers about 90 m long, and 3,450 tertiary loops. More efficient designs for the heat exchangers and improvements to the tertiary loops applying branched flow networks are desired to reduce the number of heat exchangers and tertiary loops and to make the heat exchangers smaller. Heat lost to the ground from the tertiary loops comprised 80%-90% of the heat loss. Applications of the larger pipe or loops using the branched flow network or double-pipe are required for more efficient heat utilization. More than 90% of the construction cost went into thermal insulators. The thickness and properties of the insulator must be reevaluated for economical heat delivery.
format article
author Seiji KASAHARA
Tetsuya MURATA
Yu KAMIJI
Atsuhiko TERADA
Xing YAN
Yoshiyuki INAGAKI
Michitsugu MORI
author_facet Seiji KASAHARA
Tetsuya MURATA
Yu KAMIJI
Atsuhiko TERADA
Xing YAN
Yoshiyuki INAGAKI
Michitsugu MORI
author_sort Seiji KASAHARA
title Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor
title_short Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor
title_full Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor
title_fullStr Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor
title_full_unstemmed Heat transport analysis in a district heating system applying waste heat from GTHTR300, a commercial design of high-temperature gas-cooled reactor
title_sort heat transport analysis in a district heating system applying waste heat from gthtr300, a commercial design of high-temperature gas-cooled reactor
publisher The Japan Society of Mechanical Engineers
publishDate 2016
url https://doaj.org/article/28b49ea1d11143ecb608415518b08ff3
work_keys_str_mv AT seijikasahara heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
AT tetsuyamurata heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
AT yukamiji heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
AT atsuhikoterada heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
AT xingyan heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
AT yoshiyukiinagaki heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
AT michitsugumori heattransportanalysisinadistrictheatingsystemapplyingwasteheatfromgthtr300acommercialdesignofhightemperaturegascooledreactor
_version_ 1718409706950623232