Using Smart Control System to Enhancement the Split Air Conditioning System Performance

In IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of spl...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Farag Mahel Mohammed, Jamal Abdul-Kareem Mohammed, Mustafa Abdul-Sattar Jabbar
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2017
Materias:
Acceso en línea:https://doaj.org/article/28b4eb167d94419f8bf1e08f5fe0cf35
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:28b4eb167d94419f8bf1e08f5fe0cf35
record_format dspace
spelling oai:doaj.org-article:28b4eb167d94419f8bf1e08f5fe0cf352021-12-02T03:50:44ZUsing Smart Control System to Enhancement the Split Air Conditioning System Performance10.22153/kej.2016.05.0011818-11712312-0789https://doaj.org/article/28b4eb167d94419f8bf1e08f5fe0cf352017-12-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/318https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 In IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of split A/C system is investigated experimentally and analytically. In this paper, performance and energy saving enhancement of a split-A/C system was experimentally investigated to be efficiently compatible with elevated temperature weathers. This improvement is accomplished via Smart Control System integrate with Proportional-Integral- Differential PID algorithm. The PIC16F877A micro-controller has been programmed with the PID and PWM codes to control the speed of the proposed DC condenser fan over wide range of speed, also it has been programmed to have a smart characteristics to protect the A/C system parts as the ability to detect a refrigerant leakage, condenser fan stop, and any obstacles for the fan air flow. A comparative study between the conventional and enhanced A/C system is performed. The results show that the proposed system exhibits better performance and saves more energy than the conventional one. The Coefficient of Performance (COP) of the split- A/C system are improved by about 20.56%. Farag Mahel MohammedJamal Abdul-Kareem MohammedMustafa Abdul-Sattar JabbarAl-Khwarizmi College of Engineering – University of BaghdadarticleSplit air conditioner A/CTemperature controlFan drivePID controllerPIC16F877A microcontrollerChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 12, Iss 4 (2017)
institution DOAJ
collection DOAJ
language EN
topic Split air conditioner A/C
Temperature control
Fan drive
PID controller
PIC16F877A microcontroller
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle Split air conditioner A/C
Temperature control
Fan drive
PID controller
PIC16F877A microcontroller
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
Farag Mahel Mohammed
Jamal Abdul-Kareem Mohammed
Mustafa Abdul-Sattar Jabbar
Using Smart Control System to Enhancement the Split Air Conditioning System Performance
description In IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of split A/C system is investigated experimentally and analytically. In this paper, performance and energy saving enhancement of a split-A/C system was experimentally investigated to be efficiently compatible with elevated temperature weathers. This improvement is accomplished via Smart Control System integrate with Proportional-Integral- Differential PID algorithm. The PIC16F877A micro-controller has been programmed with the PID and PWM codes to control the speed of the proposed DC condenser fan over wide range of speed, also it has been programmed to have a smart characteristics to protect the A/C system parts as the ability to detect a refrigerant leakage, condenser fan stop, and any obstacles for the fan air flow. A comparative study between the conventional and enhanced A/C system is performed. The results show that the proposed system exhibits better performance and saves more energy than the conventional one. The Coefficient of Performance (COP) of the split- A/C system are improved by about 20.56%.
format article
author Farag Mahel Mohammed
Jamal Abdul-Kareem Mohammed
Mustafa Abdul-Sattar Jabbar
author_facet Farag Mahel Mohammed
Jamal Abdul-Kareem Mohammed
Mustafa Abdul-Sattar Jabbar
author_sort Farag Mahel Mohammed
title Using Smart Control System to Enhancement the Split Air Conditioning System Performance
title_short Using Smart Control System to Enhancement the Split Air Conditioning System Performance
title_full Using Smart Control System to Enhancement the Split Air Conditioning System Performance
title_fullStr Using Smart Control System to Enhancement the Split Air Conditioning System Performance
title_full_unstemmed Using Smart Control System to Enhancement the Split Air Conditioning System Performance
title_sort using smart control system to enhancement the split air conditioning system performance
publisher Al-Khwarizmi College of Engineering – University of Baghdad
publishDate 2017
url https://doaj.org/article/28b4eb167d94419f8bf1e08f5fe0cf35
work_keys_str_mv AT faragmahelmohammed usingsmartcontrolsystemtoenhancementthesplitairconditioningsystemperformance
AT jamalabdulkareemmohammed usingsmartcontrolsystemtoenhancementthesplitairconditioningsystemperformance
AT mustafaabdulsattarjabbar usingsmartcontrolsystemtoenhancementthesplitairconditioningsystemperformance
_version_ 1718401595296710656