Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia

Introduction: Indoor air quality in day care centers (DCCs) is an emerging research topic nowadays. Indoor air pollutants such as particulate matter (PM) and microbes have been linked to respiratory health effects in children, particularly asthma-related symptoms such as night coughs and wheezing du...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Raihan Khamal, Zaleha Md Isa, Rosnah Sutan, Nor Mohd Razif Noraini, Hasanain Faisal Ghazi
Formato: article
Lenguaje:EN
Publicado: Ubiquity Press 2019
Materias:
Acceso en línea:https://doaj.org/article/28ed55eefd284b4985f2db0bb504c657
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:28ed55eefd284b4985f2db0bb504c657
record_format dspace
spelling oai:doaj.org-article:28ed55eefd284b4985f2db0bb504c6572021-12-02T07:18:52ZIndoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia2214-999610.5334/aogh.2425https://doaj.org/article/28ed55eefd284b4985f2db0bb504c6572019-01-01T00:00:00Zhttps://annalsofglobalhealth.org/articles/2425https://doaj.org/toc/2214-9996Introduction: Indoor air quality in day care centers (DCCs) is an emerging research topic nowadays. Indoor air pollutants such as particulate matter (PM) and microbes have been linked to respiratory health effects in children, particularly asthma-related symptoms such as night coughs and wheezing due to early exposure to indoor air contaminants. Objective: The aim of this study was to determine the association between wheezing symptoms among toddlers attending DCCs and indoor particulate matter, PM10, PM2.5, and microbial count level in urban DCCs in the District of Seremban, Malaysia. Methods: Data collection was carried out at 10 DCCs located in the urban area of Seremban. Modified validated questionnaires were distributed to parents to obtain their children’s health symptoms. The parameters measured were indoor PM2.5, PM10, carbon monoxide, total bacteria count, total fungus count, temperature, air velocity, and relative humidity using the National Institute for Occupational Safety and Health analytical method. Results: All 10 DCCs investigated had at least one indoor air quality parameter exceeding the acceptable level of standard guidelines. The prevalence of toddlers having wheezing symptoms was 18.9%. There was a significant different in mean concentration of PM2.5 and total bacteria count between those with and those without wheezing symptoms ('P' = 0.02, 'P' = 0.006). Conclusions: Urban DCCs are exposed to many air pollutants that may enter their buildings from various adjacent sources. The particle concentrations and presence of microbes in DCCs might increase the risk of exposed children for respiratory diseases, particularly asthma, in their later life.Raihan KhamalZaleha Md IsaRosnah SutanNor Mohd Razif NorainiHasanain Faisal GhaziUbiquity PressarticleInfectious and parasitic diseasesRC109-216Public aspects of medicineRA1-1270ENAnnals of Global Health, Vol 85, Iss 1 (2019)
institution DOAJ
collection DOAJ
language EN
topic Infectious and parasitic diseases
RC109-216
Public aspects of medicine
RA1-1270
spellingShingle Infectious and parasitic diseases
RC109-216
Public aspects of medicine
RA1-1270
Raihan Khamal
Zaleha Md Isa
Rosnah Sutan
Nor Mohd Razif Noraini
Hasanain Faisal Ghazi
Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia
description Introduction: Indoor air quality in day care centers (DCCs) is an emerging research topic nowadays. Indoor air pollutants such as particulate matter (PM) and microbes have been linked to respiratory health effects in children, particularly asthma-related symptoms such as night coughs and wheezing due to early exposure to indoor air contaminants. Objective: The aim of this study was to determine the association between wheezing symptoms among toddlers attending DCCs and indoor particulate matter, PM10, PM2.5, and microbial count level in urban DCCs in the District of Seremban, Malaysia. Methods: Data collection was carried out at 10 DCCs located in the urban area of Seremban. Modified validated questionnaires were distributed to parents to obtain their children’s health symptoms. The parameters measured were indoor PM2.5, PM10, carbon monoxide, total bacteria count, total fungus count, temperature, air velocity, and relative humidity using the National Institute for Occupational Safety and Health analytical method. Results: All 10 DCCs investigated had at least one indoor air quality parameter exceeding the acceptable level of standard guidelines. The prevalence of toddlers having wheezing symptoms was 18.9%. There was a significant different in mean concentration of PM2.5 and total bacteria count between those with and those without wheezing symptoms ('P' = 0.02, 'P' = 0.006). Conclusions: Urban DCCs are exposed to many air pollutants that may enter their buildings from various adjacent sources. The particle concentrations and presence of microbes in DCCs might increase the risk of exposed children for respiratory diseases, particularly asthma, in their later life.
format article
author Raihan Khamal
Zaleha Md Isa
Rosnah Sutan
Nor Mohd Razif Noraini
Hasanain Faisal Ghazi
author_facet Raihan Khamal
Zaleha Md Isa
Rosnah Sutan
Nor Mohd Razif Noraini
Hasanain Faisal Ghazi
author_sort Raihan Khamal
title Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia
title_short Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia
title_full Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia
title_fullStr Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia
title_full_unstemmed Indoor Particulate Matters, Microbial Count Assessments, and Wheezing Symptoms among Toddlers in Urban Day Care Centers in the District of Seremban, Malaysia
title_sort indoor particulate matters, microbial count assessments, and wheezing symptoms among toddlers in urban day care centers in the district of seremban, malaysia
publisher Ubiquity Press
publishDate 2019
url https://doaj.org/article/28ed55eefd284b4985f2db0bb504c657
work_keys_str_mv AT raihankhamal indoorparticulatemattersmicrobialcountassessmentsandwheezingsymptomsamongtoddlersinurbandaycarecentersinthedistrictofserembanmalaysia
AT zalehamdisa indoorparticulatemattersmicrobialcountassessmentsandwheezingsymptomsamongtoddlersinurbandaycarecentersinthedistrictofserembanmalaysia
AT rosnahsutan indoorparticulatemattersmicrobialcountassessmentsandwheezingsymptomsamongtoddlersinurbandaycarecentersinthedistrictofserembanmalaysia
AT normohdrazifnoraini indoorparticulatemattersmicrobialcountassessmentsandwheezingsymptomsamongtoddlersinurbandaycarecentersinthedistrictofserembanmalaysia
AT hasanainfaisalghazi indoorparticulatemattersmicrobialcountassessmentsandwheezingsymptomsamongtoddlersinurbandaycarecentersinthedistrictofserembanmalaysia
_version_ 1718399508696530944