Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study

Martin Alexander Leitritz, Focke Ziemssen, Karl Ulrich Bartz-Schmidt, Bogomil Voykov Centre for Ophthalmology, University Eye Hospital, Eberhard Karls University of Tübingen, Tübingen, Germany Purpose: To evaluate a digital high-speed camera combined with digital morphometry sof...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Leitritz MA, Ziemssen F, Bartz-Schmidt KU, Voykov B
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://doaj.org/article/2960d218d13f4ed28252f9ebc903e413
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2960d218d13f4ed28252f9ebc903e413
record_format dspace
spelling oai:doaj.org-article:2960d218d13f4ed28252f9ebc903e4132021-12-02T07:40:16ZUsing a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study1177-5483https://doaj.org/article/2960d218d13f4ed28252f9ebc903e4132014-07-01T00:00:00Zhttp://www.dovepress.com/using-a-slit-lamp-mounted-digital-high-speed-camera-for-dynamic-observ-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483 Martin Alexander Leitritz, Focke Ziemssen, Karl Ulrich Bartz-Schmidt, Bogomil Voykov Centre for Ophthalmology, University Eye Hospital, Eberhard Karls University of Tübingen, Tübingen, Germany Purpose: To evaluate a digital high-speed camera combined with digital morphometry software for dynamic measurements of phakic intraocular lens movements to observe kinetic influences, particularly in fast direction changes and at lateral end points. Materials and methods: A high-speed camera taking 300 frames per second observed movements of eight iris-claw intraocular lenses and two angle-supported intraocular lenses. Standardized saccades were performed by the patients to trigger mass inertia with lens position changes. Freeze images with maximum deviation were used for digital software-based morphometry analysis with ImageJ.Results: Two eyes from each of five patients (median age 32 years, range 28–45 years) without findings other than refractive errors were included. The high-speed images showed sufficient usability for further morphometric processing. In the primary eye position, the median decentrations downward and in a lateral direction were -0.32 mm (range -0.69 to 0.024) and 0.175 mm (range -0.37 to 0.45), respectively. Despite the small sample size of asymptomatic patients, we found a considerable amount of lens dislocation. The median distance amplitude during eye movements was 0.158 mm (range 0.02–0.84). There was a slight positive corrlation (r=0.39, P<0.001) between the grade of deviation in the primary position and the distance increase triggered by movements.Conclusion: With the use of a slit lamp-mounted high-speed camera system and morphometry software, observation and objective measurements of iris-claw intraocular lenses and angle-supported intraocular lenses movements seem to be possible. Slight decentration in the primary position might be an indicator of increased lens mobility during kinetic stress during eye movements. Long-term assessment by high-speed analysis with higher case numbers has to clarify the relationship between progressing motility and endothelial cell damage. Keywords: intraocular lens, high-speed camera, phakic lensLeitritz MAZiemssen FBartz-Schmidt KUVoykov BDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2014, Iss default, Pp 1361-1367 (2014)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Leitritz MA
Ziemssen F
Bartz-Schmidt KU
Voykov B
Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
description Martin Alexander Leitritz, Focke Ziemssen, Karl Ulrich Bartz-Schmidt, Bogomil Voykov Centre for Ophthalmology, University Eye Hospital, Eberhard Karls University of Tübingen, Tübingen, Germany Purpose: To evaluate a digital high-speed camera combined with digital morphometry software for dynamic measurements of phakic intraocular lens movements to observe kinetic influences, particularly in fast direction changes and at lateral end points. Materials and methods: A high-speed camera taking 300 frames per second observed movements of eight iris-claw intraocular lenses and two angle-supported intraocular lenses. Standardized saccades were performed by the patients to trigger mass inertia with lens position changes. Freeze images with maximum deviation were used for digital software-based morphometry analysis with ImageJ.Results: Two eyes from each of five patients (median age 32 years, range 28–45 years) without findings other than refractive errors were included. The high-speed images showed sufficient usability for further morphometric processing. In the primary eye position, the median decentrations downward and in a lateral direction were -0.32 mm (range -0.69 to 0.024) and 0.175 mm (range -0.37 to 0.45), respectively. Despite the small sample size of asymptomatic patients, we found a considerable amount of lens dislocation. The median distance amplitude during eye movements was 0.158 mm (range 0.02–0.84). There was a slight positive corrlation (r=0.39, P<0.001) between the grade of deviation in the primary position and the distance increase triggered by movements.Conclusion: With the use of a slit lamp-mounted high-speed camera system and morphometry software, observation and objective measurements of iris-claw intraocular lenses and angle-supported intraocular lenses movements seem to be possible. Slight decentration in the primary position might be an indicator of increased lens mobility during kinetic stress during eye movements. Long-term assessment by high-speed analysis with higher case numbers has to clarify the relationship between progressing motility and endothelial cell damage. Keywords: intraocular lens, high-speed camera, phakic lens
format article
author Leitritz MA
Ziemssen F
Bartz-Schmidt KU
Voykov B
author_facet Leitritz MA
Ziemssen F
Bartz-Schmidt KU
Voykov B
author_sort Leitritz MA
title Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
title_short Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
title_full Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
title_fullStr Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
title_full_unstemmed Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
title_sort using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study
publisher Dove Medical Press
publishDate 2014
url https://doaj.org/article/2960d218d13f4ed28252f9ebc903e413
work_keys_str_mv AT leitritzma usingaslitlampmounteddigitalhighspeedcamerafordynamicobservationofphakiclensesduringeyemovementsapilotstudy
AT ziemssenf usingaslitlampmounteddigitalhighspeedcamerafordynamicobservationofphakiclensesduringeyemovementsapilotstudy
AT bartzschmidtku usingaslitlampmounteddigitalhighspeedcamerafordynamicobservationofphakiclensesduringeyemovementsapilotstudy
AT voykovb usingaslitlampmounteddigitalhighspeedcamerafordynamicobservationofphakiclensesduringeyemovementsapilotstudy
_version_ 1718399270724304896