Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes

During the operation of swimming pools, large losses of water from the backwash of swimming pool filters are observed. This water is often discharged into sewers or used to sprinkle sports grounds. The aim of the research was to design and build an installation for purification and recovery of backw...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Waldemar Studziński, Wojciech Poćwiardowski, Weronika Osińska
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/29643209a0d043b58b293e5131957577
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:29643209a0d043b58b293e5131957577
record_format dspace
spelling oai:doaj.org-article:29643209a0d043b58b293e51319575772021-11-11T18:35:35ZApplication of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes10.3390/molecules262166201420-3049https://doaj.org/article/29643209a0d043b58b293e51319575772021-10-01T00:00:00Zhttps://www.mdpi.com/1420-3049/26/21/6620https://doaj.org/toc/1420-3049During the operation of swimming pools, large losses of water from the backwash of swimming pool filters are observed. This water is often discharged into sewers or used to sprinkle sports grounds. The aim of the research was to design and build an installation for purification and recovery of backwash water (BWW). It consists of flocculation, pre-filtration, and ultrafiltration based on filter tubes and ozone disinfection. Backwash water treatment installation contributes to purification and improvement of water quality. The effectiveness of the removal of microbial contamination with the use of the system was over 99%. The high efficiency of removing physicochemical impurities was also achieved. Water turbidity was reduced from 96.9 NTU to 0.13 NTU. After using the system, the oxidability of water decreased from 6.26 mg O<sub>2</sub>∙dm<sup>−3</sup> to 0.4 mg O<sub>2</sub>∙dm<sup>−3</sup>. When using the system, a reduction of total organic carbon by 80% was also noticed. After the treatment process, water meets the strict criteria and can be returned to the pool system of water as fresh water with parameters of supply water—directly to the overflow tank. It has been shown that up to 96% of water can be recovered with the technology. The cost comparison showed annual savings of over EUR 9000.Waldemar StudzińskiWojciech PoćwiardowskiWeronika OsińskaMDPI AGarticlebackwash waterswimming poolmanagement of backwash waterultrafiltrationOrganic chemistryQD241-441ENMolecules, Vol 26, Iss 6620, p 6620 (2021)
institution DOAJ
collection DOAJ
language EN
topic backwash water
swimming pool
management of backwash water
ultrafiltration
Organic chemistry
QD241-441
spellingShingle backwash water
swimming pool
management of backwash water
ultrafiltration
Organic chemistry
QD241-441
Waldemar Studziński
Wojciech Poćwiardowski
Weronika Osińska
Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes
description During the operation of swimming pools, large losses of water from the backwash of swimming pool filters are observed. This water is often discharged into sewers or used to sprinkle sports grounds. The aim of the research was to design and build an installation for purification and recovery of backwash water (BWW). It consists of flocculation, pre-filtration, and ultrafiltration based on filter tubes and ozone disinfection. Backwash water treatment installation contributes to purification and improvement of water quality. The effectiveness of the removal of microbial contamination with the use of the system was over 99%. The high efficiency of removing physicochemical impurities was also achieved. Water turbidity was reduced from 96.9 NTU to 0.13 NTU. After using the system, the oxidability of water decreased from 6.26 mg O<sub>2</sub>∙dm<sup>−3</sup> to 0.4 mg O<sub>2</sub>∙dm<sup>−3</sup>. When using the system, a reduction of total organic carbon by 80% was also noticed. After the treatment process, water meets the strict criteria and can be returned to the pool system of water as fresh water with parameters of supply water—directly to the overflow tank. It has been shown that up to 96% of water can be recovered with the technology. The cost comparison showed annual savings of over EUR 9000.
format article
author Waldemar Studziński
Wojciech Poćwiardowski
Weronika Osińska
author_facet Waldemar Studziński
Wojciech Poćwiardowski
Weronika Osińska
author_sort Waldemar Studziński
title Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes
title_short Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes
title_full Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes
title_fullStr Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes
title_full_unstemmed Application of the Swimming Pool Backwash Water Recovery System with the Use of Filter Tubes
title_sort application of the swimming pool backwash water recovery system with the use of filter tubes
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/29643209a0d043b58b293e5131957577
work_keys_str_mv AT waldemarstudzinski applicationoftheswimmingpoolbackwashwaterrecoverysystemwiththeuseoffiltertubes
AT wojciechpocwiardowski applicationoftheswimmingpoolbackwashwaterrecoverysystemwiththeuseoffiltertubes
AT weronikaosinska applicationoftheswimmingpoolbackwashwaterrecoverysystemwiththeuseoffiltertubes
_version_ 1718431752133804032