A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe

Devin DeLuna,1 Audrey Netzel,2 Jamie Dietze,1 Brett A Begley,1 Jideofor K Ndulue,1 Donny W Suh1 1Department of Ophthalmology, University of Nebraska Medical Center, Omaha, NE, USA; 2Department of Ophthalmology, Creighton University School of Medicine, Omaha, NE, USACorrespondence: Audrey NetzelDepar...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: DeLuna D, Netzel A, Dietze J, Begley BA, Ndulue JK, Suh DW
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/29acb3f0ac8045fea37891b9a12d3316
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:29acb3f0ac8045fea37891b9a12d3316
record_format dspace
spelling oai:doaj.org-article:29acb3f0ac8045fea37891b9a12d33162021-12-02T08:38:38ZA comparison in precision and accuracy of the conventional syringe to the Suh precision syringe1177-5483https://doaj.org/article/29acb3f0ac8045fea37891b9a12d33162019-09-01T00:00:00Zhttps://www.dovepress.com/a-comparison-in-precision-and-accuracy-of-the-conventional-syringe-to--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Devin DeLuna,1 Audrey Netzel,2 Jamie Dietze,1 Brett A Begley,1 Jideofor K Ndulue,1 Donny W Suh1 1Department of Ophthalmology, University of Nebraska Medical Center, Omaha, NE, USA; 2Department of Ophthalmology, Creighton University School of Medicine, Omaha, NE, USACorrespondence: Audrey NetzelDepartment of Ophthalmology, Creighton University School of Medicine, 626 N 41st Street, Omaha, NE 68131, USATel +1 608 214 7857Email audreynetzel@creighton.eduPurpose: To compare the accuracy and precision of a conventional intraocular syringe to the Suh precision syringe (SPS), a new injection device designed to decrease operator error and to reduce adverse outcomes by providing a more ergonomic technique for periocular and intraocular injections.Methods: Participants were instructed to inject a specified quantity of water into a 0.2 mL polymerase chain reaction (PCR) tube and a sheep eye, first with the conventional syringe, and then with the SPS. The degree of needle movement during injection was video recorded and analyzed for forward-retraction movement and variability in movement. The volume of water injected into the PCR tube was also documented. Data was analyzed using a Wilcoxon signed-rank test.Results: As compared to the conventional syringe, the SPS had significantly less forward-retraction movement when injecting into the sheep eye (P=0.04). Similarly, the forward-retraction movement of the needle when injecting into the PCR tube was less while using the SPS compared with the conventional syringe; however, this was not statistically significant (P=0.09). There was no significant difference in the volume of water expelled from both syringes (P=0.28).Conclusion: The SPS demonstrates significant potential to decrease the overall risk involved with injections through reduction of forward-retraction movement during device operation. This new syringe design also provides better control with injection depth and drug injection volume. With its more ergonomic design, the SPS has the potential to decrease risks associated with intraocular injections by improving the accuracy and precision of the injection.Keywords: Suh precision syringe, intraocular injectionDeLuna DNetzel ADietze JBegley BANdulue JKSuh DWDove Medical PressarticleSuh Precision SyringeIntraocular InjectionOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 1833-1839 (2019)
institution DOAJ
collection DOAJ
language EN
topic Suh Precision Syringe
Intraocular Injection
Ophthalmology
RE1-994
spellingShingle Suh Precision Syringe
Intraocular Injection
Ophthalmology
RE1-994
DeLuna D
Netzel A
Dietze J
Begley BA
Ndulue JK
Suh DW
A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe
description Devin DeLuna,1 Audrey Netzel,2 Jamie Dietze,1 Brett A Begley,1 Jideofor K Ndulue,1 Donny W Suh1 1Department of Ophthalmology, University of Nebraska Medical Center, Omaha, NE, USA; 2Department of Ophthalmology, Creighton University School of Medicine, Omaha, NE, USACorrespondence: Audrey NetzelDepartment of Ophthalmology, Creighton University School of Medicine, 626 N 41st Street, Omaha, NE 68131, USATel +1 608 214 7857Email audreynetzel@creighton.eduPurpose: To compare the accuracy and precision of a conventional intraocular syringe to the Suh precision syringe (SPS), a new injection device designed to decrease operator error and to reduce adverse outcomes by providing a more ergonomic technique for periocular and intraocular injections.Methods: Participants were instructed to inject a specified quantity of water into a 0.2 mL polymerase chain reaction (PCR) tube and a sheep eye, first with the conventional syringe, and then with the SPS. The degree of needle movement during injection was video recorded and analyzed for forward-retraction movement and variability in movement. The volume of water injected into the PCR tube was also documented. Data was analyzed using a Wilcoxon signed-rank test.Results: As compared to the conventional syringe, the SPS had significantly less forward-retraction movement when injecting into the sheep eye (P=0.04). Similarly, the forward-retraction movement of the needle when injecting into the PCR tube was less while using the SPS compared with the conventional syringe; however, this was not statistically significant (P=0.09). There was no significant difference in the volume of water expelled from both syringes (P=0.28).Conclusion: The SPS demonstrates significant potential to decrease the overall risk involved with injections through reduction of forward-retraction movement during device operation. This new syringe design also provides better control with injection depth and drug injection volume. With its more ergonomic design, the SPS has the potential to decrease risks associated with intraocular injections by improving the accuracy and precision of the injection.Keywords: Suh precision syringe, intraocular injection
format article
author DeLuna D
Netzel A
Dietze J
Begley BA
Ndulue JK
Suh DW
author_facet DeLuna D
Netzel A
Dietze J
Begley BA
Ndulue JK
Suh DW
author_sort DeLuna D
title A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe
title_short A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe
title_full A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe
title_fullStr A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe
title_full_unstemmed A comparison in precision and accuracy of the conventional syringe to the Suh precision syringe
title_sort comparison in precision and accuracy of the conventional syringe to the suh precision syringe
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/29acb3f0ac8045fea37891b9a12d3316
work_keys_str_mv AT delunad acomparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT netzela acomparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT dietzej acomparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT begleyba acomparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT nduluejk acomparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT suhdw acomparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT delunad comparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT netzela comparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT dietzej comparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT begleyba comparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT nduluejk comparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
AT suhdw comparisoninprecisionandaccuracyoftheconventionalsyringetothesuhprecisionsyringe
_version_ 1718398408926953472