Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors

Asato Hasegawa,1 Takashi Kojima,2 Mana Yamamoto,1 Yukihito Kato,3 Akeno Tamaoki,1,4 Kazuo Ichikawa3 1Department of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan; 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan; 3Department of Op...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hasegawa A, Kojima T, Yamamoto M, Kato Y, Tamaoki A, Ichikawa K
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/2a89b7b4c9414baba1d4dd05fa1fb8d4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2a89b7b4c9414baba1d4dd05fa1fb8d4
record_format dspace
spelling oai:doaj.org-article:2a89b7b4c9414baba1d4dd05fa1fb8d42021-12-02T08:47:41ZImpact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors1177-5483https://doaj.org/article/2a89b7b4c9414baba1d4dd05fa1fb8d42018-08-01T00:00:00Zhttps://www.dovepress.com/impact-of-the-anterior-posterior-corneal-radius-ratio-on-intraocular-l-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Asato Hasegawa,1 Takashi Kojima,2 Mana Yamamoto,1 Yukihito Kato,3 Akeno Tamaoki,1,4 Kazuo Ichikawa3 1Department of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan; 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan; 3Department of Ophthalmology, Chukyo Eye Clinic, Nagoya, Japan; 4Department of Mathematics and System Development, Shinshu University Interdisciplinary Graduate School of Science and Technology, Nagano, Japan Purpose: To evaluate the distribution of the anterior–posterior corneal radius ratio (AP ratio; anterior corneal radius/posterior corneal radius) in patients before cataract surgery, and investigate which parameters can affect this ratio. We also investigated the impact of the AP ratio on the intraocular lens (IOL) power calculation error in cataract surgery. Method: A total of 501 eyes of 501 consecutive patients who had no history of corneal diseases and had undergone cataract surgery were enrolled in this study. The patients’ AP ratio was measured before surgery using anterior segment optical coherence tomography; using these data, we evaluated the correlation between the AP ratio and various parameters that can affect the corneal radius. For subgroup analyses, we investigated the correlation between the AP ratio and IOL power calculation error in 181 eyes of 181 patients. Stepwise multiple regression analysis was performed with the IOL power calculation errors of the SRK/T, Haigis, Holladay 1, and Hoffer Q formulas as the dependent variables and various parameters that can affect the postoperative IOL power calculation error as the independent variables. Results: The mean AP ratio was 1.19±0.02, and it weakly correlated with corneal thickness, horizontal corneal diameter, and posterior corneal radius. The correlations between the AP ratio and IOL power calculation errors in the 4 calculation formulas were not statistically significant. Stepwise multiple regression analysis could not detect any significant parameters affecting this ratio. Conclusion: The AP ratio has no major influence on IOL power calculation error in patients with any history of corneal disease. Keywords: cataract surgery, anterior-posterior corneal radius ratio, intraocular lens power calculationHasegawa AKojima TYamamoto MKato YTamaoki AIchikawa KDove Medical PressarticleCataract surgeryanterior-posterior corneal radius ratiointraocular lens power calculationOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 1549-1558 (2018)
institution DOAJ
collection DOAJ
language EN
topic Cataract surgery
anterior-posterior corneal radius ratio
intraocular lens power calculation
Ophthalmology
RE1-994
spellingShingle Cataract surgery
anterior-posterior corneal radius ratio
intraocular lens power calculation
Ophthalmology
RE1-994
Hasegawa A
Kojima T
Yamamoto M
Kato Y
Tamaoki A
Ichikawa K
Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
description Asato Hasegawa,1 Takashi Kojima,2 Mana Yamamoto,1 Yukihito Kato,3 Akeno Tamaoki,1,4 Kazuo Ichikawa3 1Department of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan; 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan; 3Department of Ophthalmology, Chukyo Eye Clinic, Nagoya, Japan; 4Department of Mathematics and System Development, Shinshu University Interdisciplinary Graduate School of Science and Technology, Nagano, Japan Purpose: To evaluate the distribution of the anterior–posterior corneal radius ratio (AP ratio; anterior corneal radius/posterior corneal radius) in patients before cataract surgery, and investigate which parameters can affect this ratio. We also investigated the impact of the AP ratio on the intraocular lens (IOL) power calculation error in cataract surgery. Method: A total of 501 eyes of 501 consecutive patients who had no history of corneal diseases and had undergone cataract surgery were enrolled in this study. The patients’ AP ratio was measured before surgery using anterior segment optical coherence tomography; using these data, we evaluated the correlation between the AP ratio and various parameters that can affect the corneal radius. For subgroup analyses, we investigated the correlation between the AP ratio and IOL power calculation error in 181 eyes of 181 patients. Stepwise multiple regression analysis was performed with the IOL power calculation errors of the SRK/T, Haigis, Holladay 1, and Hoffer Q formulas as the dependent variables and various parameters that can affect the postoperative IOL power calculation error as the independent variables. Results: The mean AP ratio was 1.19±0.02, and it weakly correlated with corneal thickness, horizontal corneal diameter, and posterior corneal radius. The correlations between the AP ratio and IOL power calculation errors in the 4 calculation formulas were not statistically significant. Stepwise multiple regression analysis could not detect any significant parameters affecting this ratio. Conclusion: The AP ratio has no major influence on IOL power calculation error in patients with any history of corneal disease. Keywords: cataract surgery, anterior-posterior corneal radius ratio, intraocular lens power calculation
format article
author Hasegawa A
Kojima T
Yamamoto M
Kato Y
Tamaoki A
Ichikawa K
author_facet Hasegawa A
Kojima T
Yamamoto M
Kato Y
Tamaoki A
Ichikawa K
author_sort Hasegawa A
title Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
title_short Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
title_full Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
title_fullStr Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
title_full_unstemmed Impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
title_sort impact of the anterior-posterior corneal radius ratio on intraocular lens power calculation errors
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/2a89b7b4c9414baba1d4dd05fa1fb8d4
work_keys_str_mv AT hasegawaa impactoftheanteriorposteriorcornealradiusratioonintraocularlenspowercalculationerrors
AT kojimat impactoftheanteriorposteriorcornealradiusratioonintraocularlenspowercalculationerrors
AT yamamotom impactoftheanteriorposteriorcornealradiusratioonintraocularlenspowercalculationerrors
AT katoy impactoftheanteriorposteriorcornealradiusratioonintraocularlenspowercalculationerrors
AT tamaokia impactoftheanteriorposteriorcornealradiusratioonintraocularlenspowercalculationerrors
AT ichikawak impactoftheanteriorposteriorcornealradiusratioonintraocularlenspowercalculationerrors
_version_ 1718398354651611136