Monitoring the tissue perfusion during hemorrhagic shock and resuscitation: tissue-to-arterial carbon dioxide partial pressure gradient in a pig model

Abstract Background Despite much evidence supporting the monitoring of the divergence of transcutaneous partial pressure of carbon dioxide (tcPCO2) from arterial partial pressure carbon dioxide (artPCO2) as an indicator of the shock status, data are limited on the relationships of the gradient betwe...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yusuke Endo, Taku Hirokawa, Taku Miyasho, Ryosuke Takegawa, Koichiro Shinozaki, Daniel M. Rolston, Lance B. Becker, Kei Hayashida
Formato: article
Lenguaje:EN
Publicado: BMC 2021
Materias:
R
Acceso en línea:https://doaj.org/article/2ae9937a1d99490da6ff835f2f18e9e1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract Background Despite much evidence supporting the monitoring of the divergence of transcutaneous partial pressure of carbon dioxide (tcPCO2) from arterial partial pressure carbon dioxide (artPCO2) as an indicator of the shock status, data are limited on the relationships of the gradient between tcPCO2 and artPCO2 (tc-artPCO2) with the systemic oxygen metabolism and hemodynamic parameters. Our study aimed to test the hypothesis that tc-artPCO2 can detect inadequate tissue perfusion during hemorrhagic shock and resuscitation. Methods This prospective animal study was performed using female pigs at a university-based experimental laboratory. Progressive massive hemorrhagic shock was induced in mechanically ventilated pigs by stepwise blood withdrawal. All animals were then resuscitated by transfusing the stored blood in stages. A transcutaneous monitor was attached to their ears to measure tcPCO2. A pulmonary artery catheter (PAC) and pulse index continuous cardiac output (PiCCO) were used to monitor cardiac output (CO) and several hemodynamic parameters. The relationships of tc-artPCO2 with the study parameters and systemic oxygen delivery (DO2) were analyzed. Results Hemorrhage and blood transfusion precisely impacted hemodynamic and laboratory data as expected. The tc-artPCO2 level markedly increased as CO decreased. There were significant correlations of tc-artPCO2 with DO2 and COs (DO2: r = − 0.83, CO by PAC: r = − 0.79; CO by PiCCO: r = − 0.74; all P < 0.0001). The critical level of oxygen delivery (DO2crit) was 11.72 mL/kg/min according to transcutaneous partial pressure of oxygen (threshold of 30 mmHg). Receiver operating characteristic curve analyses revealed that the value of tc-artPCO2 for discrimination of DO2crit was highest with an area under the curve (AUC) of 0.94, followed by shock index (AUC = 0.78; P < 0.04 vs tc-artPCO2), and lactate (AUC = 0.65; P < 0.001 vs tc-artPCO2). Conclusions Our observations suggest the less-invasive tc-artPCO2 monitoring can sensitively detect inadequate systemic oxygen supply during hemorrhagic shock. Further evaluations are required in different forms of shock in other large animal models and in humans to assess its usefulness, safety, and ability to predict outcomes in critical illnesses.