Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report

Introduction: As one of the short-term complications after inguinal hernia repair, mesh infection frequently occurs but rarely leads to ileocutaneous fistula. We present a rare case of ileocutaneous fistula 8 years after inguinal hernia plug repair with polypropylene mesh.Case Presentation: The pati...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jiankang Zhang, Zeming Hu, Xuan Lin, Bin Chen
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://doaj.org/article/2b23ad7c8c7d485ab43fb3f5e9cd307d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2b23ad7c8c7d485ab43fb3f5e9cd307d
record_format dspace
spelling oai:doaj.org-article:2b23ad7c8c7d485ab43fb3f5e9cd307d2021-11-15T05:07:04ZLate-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report2296-875X10.3389/fsurg.2021.785087https://doaj.org/article/2b23ad7c8c7d485ab43fb3f5e9cd307d2021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fsurg.2021.785087/fullhttps://doaj.org/toc/2296-875XIntroduction: As one of the short-term complications after inguinal hernia repair, mesh infection frequently occurs but rarely leads to ileocutaneous fistula. We present a rare case of ileocutaneous fistula 8 years after inguinal hernia plug repair with polypropylene mesh.Case Presentation: The patient was a 67-year-old male who underwent a plug repair with polypropylene mesh of the right inguinal hernia. Eight years after the primary repair, skin ulceration with pus presented in the right groin area, and the final diagnosis was enterocutaneous fistula. According to laparoscopic exploration, the ileum below the fistula closely adhered to the abdominal wall. After gently separating the bowel loop, a defect area of about 2 × 3 cm was observed on the surface of the ileum. In laparotomy, the plug was found embedded in the ileum and then was completely removed, and an ileum side-to-side anastomosis was performed. The patient was discharged 2 weeks after the surgery, and follow-up at the sixth month revealed complete healing of the wound and no evidence of hernia recurrence.Conclusion: Late-onset ileocutaneous fistula should be considered in the differential diagnosis in patients who present inflammation and abscess formation after hernia repair. Besides, for patients with suspected intestinal fistula after hernia repair, laparoscopic exploration should be given priority, and the mesh removal approach should be tailored according to the results of laparoscopic exploration.Jiankang ZhangZeming HuXuan LinBin ChenFrontiers Media S.A.articlelaparoscopic explorationmeshlate-onsetinguinal herniaintestinal fistulacase reportSurgeryRD1-811ENFrontiers in Surgery, Vol 8 (2021)
institution DOAJ
collection DOAJ
language EN
topic laparoscopic exploration
mesh
late-onset
inguinal hernia
intestinal fistula
case report
Surgery
RD1-811
spellingShingle laparoscopic exploration
mesh
late-onset
inguinal hernia
intestinal fistula
case report
Surgery
RD1-811
Jiankang Zhang
Zeming Hu
Xuan Lin
Bin Chen
Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report
description Introduction: As one of the short-term complications after inguinal hernia repair, mesh infection frequently occurs but rarely leads to ileocutaneous fistula. We present a rare case of ileocutaneous fistula 8 years after inguinal hernia plug repair with polypropylene mesh.Case Presentation: The patient was a 67-year-old male who underwent a plug repair with polypropylene mesh of the right inguinal hernia. Eight years after the primary repair, skin ulceration with pus presented in the right groin area, and the final diagnosis was enterocutaneous fistula. According to laparoscopic exploration, the ileum below the fistula closely adhered to the abdominal wall. After gently separating the bowel loop, a defect area of about 2 × 3 cm was observed on the surface of the ileum. In laparotomy, the plug was found embedded in the ileum and then was completely removed, and an ileum side-to-side anastomosis was performed. The patient was discharged 2 weeks after the surgery, and follow-up at the sixth month revealed complete healing of the wound and no evidence of hernia recurrence.Conclusion: Late-onset ileocutaneous fistula should be considered in the differential diagnosis in patients who present inflammation and abscess formation after hernia repair. Besides, for patients with suspected intestinal fistula after hernia repair, laparoscopic exploration should be given priority, and the mesh removal approach should be tailored according to the results of laparoscopic exploration.
format article
author Jiankang Zhang
Zeming Hu
Xuan Lin
Bin Chen
author_facet Jiankang Zhang
Zeming Hu
Xuan Lin
Bin Chen
author_sort Jiankang Zhang
title Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report
title_short Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report
title_full Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report
title_fullStr Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report
title_full_unstemmed Late-Onset Ileocutaneous Fistula Eight Years After Plug Repair With Polypropylene Mesh: A Case Report
title_sort late-onset ileocutaneous fistula eight years after plug repair with polypropylene mesh: a case report
publisher Frontiers Media S.A.
publishDate 2021
url https://doaj.org/article/2b23ad7c8c7d485ab43fb3f5e9cd307d
work_keys_str_mv AT jiankangzhang lateonsetileocutaneousfistulaeightyearsafterplugrepairwithpolypropylenemeshacasereport
AT zeminghu lateonsetileocutaneousfistulaeightyearsafterplugrepairwithpolypropylenemeshacasereport
AT xuanlin lateonsetileocutaneousfistulaeightyearsafterplugrepairwithpolypropylenemeshacasereport
AT binchen lateonsetileocutaneousfistulaeightyearsafterplugrepairwithpolypropylenemeshacasereport
_version_ 1718428797423845376