Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines
In the present work, a methodology that allows optimizing the permanent magnet synchronous generator (PMSG) design by establishing limit values of magnet radius and length that maximize efficiency for the nominal parameters of the wind turbine is developed. The methodology consists of two fundamenta...
Guardado en:
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2b6ac16e57564b789438c868e2a2f10b |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:2b6ac16e57564b789438c868e2a2f10b |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2b6ac16e57564b789438c868e2a2f10b2021-11-11T15:54:13ZDimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines10.3390/en142171061996-1073https://doaj.org/article/2b6ac16e57564b789438c868e2a2f10b2021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/21/7106https://doaj.org/toc/1996-1073In the present work, a methodology that allows optimizing the permanent magnet synchronous generator (PMSG) design by establishing limit values of magnet radius and length that maximize efficiency for the nominal parameters of the wind turbine is developed. The methodology consists of two fundamental models. One model calculates the generator parameters from the radius of the magnet base, and the other optimization model determines two optimum generators according to the optimization criteria of maximum efficiency and maximum efficiency with minimum weight starting from the axial length and the radius of the magnet base. For the optimization, the numerical method of the golden section was used. The model was validated from a 10 kW PMSG and the results of two optimum generators are presented according to the optimization criteria. In addition, when the obtained results are compared with the reference electric generator, an increase in efficiency of 1.15% and 0.81% and a reduction in weight of 30.79% and 39.15% of the optimized generators are obtained for maximum efficiency and minimum weight, respectively. Intermediate options between the maximum efficiency generator and the minimum weight generator allows for the selection of the optimum dimensioning for the electric generator as a function of the parameters from the wind turbine design.Jesús Antonio Enríquez SantiagoOrlando Lastres DanguillecourtGuillermo Ibáñez DuharteJorge Evaristo Conde DíazAntonio Verde AñorveQuetzalcoatl Hernandez EscobedoJoel Pantoja EnríquezLaura VereaGeovanni Hernández GalvezRafael Dorrego PortelaAlberto-Jesus Perea-MorenoMDPI AGarticlewind turbinesPM generatorsoptimization of electric generatorsdesign of electric generatorsTechnologyTENEnergies, Vol 14, Iss 7106, p 7106 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
wind turbines PM generators optimization of electric generators design of electric generators Technology T |
spellingShingle |
wind turbines PM generators optimization of electric generators design of electric generators Technology T Jesús Antonio Enríquez Santiago Orlando Lastres Danguillecourt Guillermo Ibáñez Duharte Jorge Evaristo Conde Díaz Antonio Verde Añorve Quetzalcoatl Hernandez Escobedo Joel Pantoja Enríquez Laura Verea Geovanni Hernández Galvez Rafael Dorrego Portela Alberto-Jesus Perea-Moreno Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines |
description |
In the present work, a methodology that allows optimizing the permanent magnet synchronous generator (PMSG) design by establishing limit values of magnet radius and length that maximize efficiency for the nominal parameters of the wind turbine is developed. The methodology consists of two fundamental models. One model calculates the generator parameters from the radius of the magnet base, and the other optimization model determines two optimum generators according to the optimization criteria of maximum efficiency and maximum efficiency with minimum weight starting from the axial length and the radius of the magnet base. For the optimization, the numerical method of the golden section was used. The model was validated from a 10 kW PMSG and the results of two optimum generators are presented according to the optimization criteria. In addition, when the obtained results are compared with the reference electric generator, an increase in efficiency of 1.15% and 0.81% and a reduction in weight of 30.79% and 39.15% of the optimized generators are obtained for maximum efficiency and minimum weight, respectively. Intermediate options between the maximum efficiency generator and the minimum weight generator allows for the selection of the optimum dimensioning for the electric generator as a function of the parameters from the wind turbine design. |
format |
article |
author |
Jesús Antonio Enríquez Santiago Orlando Lastres Danguillecourt Guillermo Ibáñez Duharte Jorge Evaristo Conde Díaz Antonio Verde Añorve Quetzalcoatl Hernandez Escobedo Joel Pantoja Enríquez Laura Verea Geovanni Hernández Galvez Rafael Dorrego Portela Alberto-Jesus Perea-Moreno |
author_facet |
Jesús Antonio Enríquez Santiago Orlando Lastres Danguillecourt Guillermo Ibáñez Duharte Jorge Evaristo Conde Díaz Antonio Verde Añorve Quetzalcoatl Hernandez Escobedo Joel Pantoja Enríquez Laura Verea Geovanni Hernández Galvez Rafael Dorrego Portela Alberto-Jesus Perea-Moreno |
author_sort |
Jesús Antonio Enríquez Santiago |
title |
Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines |
title_short |
Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines |
title_full |
Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines |
title_fullStr |
Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines |
title_full_unstemmed |
Dimensioning Optimization of the Permanent Magnet Synchronous Generator for Direct Drive Wind Turbines |
title_sort |
dimensioning optimization of the permanent magnet synchronous generator for direct drive wind turbines |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/2b6ac16e57564b789438c868e2a2f10b |
work_keys_str_mv |
AT jesusantonioenriquezsantiago dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT orlandolastresdanguillecourt dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT guillermoibanezduharte dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT jorgeevaristocondediaz dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT antonioverdeanorve dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT quetzalcoatlhernandezescobedo dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT joelpantojaenriquez dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT lauraverea dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT geovannihernandezgalvez dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT rafaeldorregoportela dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines AT albertojesuspereamoreno dimensioningoptimizationofthepermanentmagnetsynchronousgeneratorfordirectdrivewindturbines |
_version_ |
1718432909570867200 |