The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome

Iyad A Goussous,1 Mohamed-Sameh El-Agha,1 Ahmed Awadein,1 Mohamed H Hosny,1 Alaa A Ghaith,2 Ahmed L Khattab2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, 2Faculty of Medicine, Alexandria University, Alexandria, Egypt Purpose: The purpose of this study was to determin...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Goussous IA, El-Agha MS, Awadein A, Hosny MH, Ghaith AA, Khattab AL
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://doaj.org/article/2ba4c61b33be4f3a837c1a40a5b7d1e4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2ba4c61b33be4f3a837c1a40a5b7d1e4
record_format dspace
spelling oai:doaj.org-article:2ba4c61b33be4f3a837c1a40a5b7d1e42021-12-02T01:15:20ZThe effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome1177-5483https://doaj.org/article/2ba4c61b33be4f3a837c1a40a5b7d1e42017-11-01T00:00:00Zhttps://www.dovepress.com/the-effect-of-flap-thickness-on-corneal-biomechanics-after-myopic-lase-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Iyad A Goussous,1 Mohamed-Sameh El-Agha,1 Ahmed Awadein,1 Mohamed H Hosny,1 Alaa A Ghaith,2 Ahmed L Khattab2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, 2Faculty of Medicine, Alexandria University, Alexandria, Egypt Purpose: The purpose of this study was to determine the effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis (LASIK).Methods: This is a prospective controlled non-randomized, institutional study. Patients underwent either epi-LASIK with mitomycin (advanced surface ablation [ASA]), thin-flap LASIK (90 µm head), or thick-flap LASIK (130 µm head). In ASA, the Moria Epi-K hydroseparator was used. LASIK flaps were created using the Moria M-2 mechanical microkeratome. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured preoperatively and 3 months after surgery, using the Ocular Response Analyzer®.Results: Ten patients (19 eyes) underwent ASA, 11 patients (16 eyes) underwent thin-flap LASIK, and 11 patients (16 eyes) underwent thick-flap LASIK. The mean preoperative CH was 10.47±0.88, 10.52±1.4, and 11.28±1.4 mmHg (p=0.043), respectively, decreasing after surgery by 1.75±1.02, 1.66±1.00, and 2.62±1.03 mmHg (p=0.017). The mean reduction of CH per micron of central corneal ablation was 0.031, 0.023, and 0.049 mmHg/µm (p=0.005). Mean preoperative CRF was 10.11±1.28, 10.34±1.87, and 10.62±1.76 mmHg (p=0.66), decreasing after surgery by 2.33±1.35, 2.77±1.03, and 2.92±1.10 mmHg (p=0.308). The mean reduction of CRF per micron of central corneal ablation was 0.039, 0.040, and 0.051 mmHg/µm (p=0.112).Conclusion: Thick-flap LASIK caused a greater reduction of CH and CRF than thin-flap LASIK and ASA, although this was statistically significant only for CH. ASA and thin-flap LASIK were found to be biomechanically similar. Keywords: flap thickness ectasia, hysteresis, LASIK, surface ablationGoussous IAEl-Agha MSAwadein AHosny MHGhaith AAKhattab ALDove Medical PressarticleCorneal BiomechanicsHysteresisLASIKSurface AblationOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 2065-2071 (2017)
institution DOAJ
collection DOAJ
language EN
topic Corneal Biomechanics
Hysteresis
LASIK
Surface Ablation
Ophthalmology
RE1-994
spellingShingle Corneal Biomechanics
Hysteresis
LASIK
Surface Ablation
Ophthalmology
RE1-994
Goussous IA
El-Agha MS
Awadein A
Hosny MH
Ghaith AA
Khattab AL
The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
description Iyad A Goussous,1 Mohamed-Sameh El-Agha,1 Ahmed Awadein,1 Mohamed H Hosny,1 Alaa A Ghaith,2 Ahmed L Khattab2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, 2Faculty of Medicine, Alexandria University, Alexandria, Egypt Purpose: The purpose of this study was to determine the effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis (LASIK).Methods: This is a prospective controlled non-randomized, institutional study. Patients underwent either epi-LASIK with mitomycin (advanced surface ablation [ASA]), thin-flap LASIK (90 µm head), or thick-flap LASIK (130 µm head). In ASA, the Moria Epi-K hydroseparator was used. LASIK flaps were created using the Moria M-2 mechanical microkeratome. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured preoperatively and 3 months after surgery, using the Ocular Response Analyzer®.Results: Ten patients (19 eyes) underwent ASA, 11 patients (16 eyes) underwent thin-flap LASIK, and 11 patients (16 eyes) underwent thick-flap LASIK. The mean preoperative CH was 10.47±0.88, 10.52±1.4, and 11.28±1.4 mmHg (p=0.043), respectively, decreasing after surgery by 1.75±1.02, 1.66±1.00, and 2.62±1.03 mmHg (p=0.017). The mean reduction of CH per micron of central corneal ablation was 0.031, 0.023, and 0.049 mmHg/µm (p=0.005). Mean preoperative CRF was 10.11±1.28, 10.34±1.87, and 10.62±1.76 mmHg (p=0.66), decreasing after surgery by 2.33±1.35, 2.77±1.03, and 2.92±1.10 mmHg (p=0.308). The mean reduction of CRF per micron of central corneal ablation was 0.039, 0.040, and 0.051 mmHg/µm (p=0.112).Conclusion: Thick-flap LASIK caused a greater reduction of CH and CRF than thin-flap LASIK and ASA, although this was statistically significant only for CH. ASA and thin-flap LASIK were found to be biomechanically similar. Keywords: flap thickness ectasia, hysteresis, LASIK, surface ablation
format article
author Goussous IA
El-Agha MS
Awadein A
Hosny MH
Ghaith AA
Khattab AL
author_facet Goussous IA
El-Agha MS
Awadein A
Hosny MH
Ghaith AA
Khattab AL
author_sort Goussous IA
title The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
title_short The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
title_full The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
title_fullStr The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
title_full_unstemmed The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
title_sort effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the m-2 microkeratome
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/2ba4c61b33be4f3a837c1a40a5b7d1e4
work_keys_str_mv AT goussousia theeffectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT elaghams theeffectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT awadeina theeffectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT hosnymh theeffectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT ghaithaa theeffectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT khattabal theeffectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT goussousia effectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT elaghams effectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT awadeina effectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT hosnymh effectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT ghaithaa effectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
AT khattabal effectofflapthicknessoncornealbiomechanicsaftermyopiclaserinsitukeratomileusisusingthem2microkeratome
_version_ 1718403189662810112