Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics

Grid impedance is an important parameter and is used to perform impedance-based stability analysis for the operation of grid-connected systems, such as power electronics-interfaced solar, wind and other distributed power generation systems. The identification of grid impedance with the help of broad...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Matthias Buchner, Krzysztof Rudion
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/2bd868410eba4b6f863805d7a4290b48
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2bd868410eba4b6f863805d7a4290b48
record_format dspace
spelling oai:doaj.org-article:2bd868410eba4b6f863805d7a4290b482021-11-11T16:06:51ZIdentification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics10.3390/en142173981996-1073https://doaj.org/article/2bd868410eba4b6f863805d7a4290b482021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/21/7398https://doaj.org/toc/1996-1073Grid impedance is an important parameter and is used to perform impedance-based stability analysis for the operation of grid-connected systems, such as power electronics-interfaced solar, wind and other distributed power generation systems. The identification of grid impedance with the help of broadband signals is a popular method, but its robustness depends strongly on the harmonic disturbances caused by non-linear loads or power electronics. This paper provides an in-depth analysis of how harmonics affect the identification of grid impedance while using broadband measurements. Furthermore, a compensation method is proposed to remove the disturbing influences of harmonics on broadband impedance identification. This method is based on exploiting the properties of the used maximum-length binary sequence (MLBS). To explain the methodology of the proposed method, the design basis for the excitation signal is discussed in detail. The analysis from simulations and a real measurement in an industrial power grid shows the effectiveness of the proposed method in compensating the disturbing influences of harmonics on broadband impedance measurements.Matthias BuchnerKrzysztof RudionMDPI AGarticleimpedance-based stabilitysmall-signal stabilitypower electronicsharmonic disturbancesspectral leakagebroadband signalsTechnologyTENEnergies, Vol 14, Iss 7398, p 7398 (2021)
institution DOAJ
collection DOAJ
language EN
topic impedance-based stability
small-signal stability
power electronics
harmonic disturbances
spectral leakage
broadband signals
Technology
T
spellingShingle impedance-based stability
small-signal stability
power electronics
harmonic disturbances
spectral leakage
broadband signals
Technology
T
Matthias Buchner
Krzysztof Rudion
Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics
description Grid impedance is an important parameter and is used to perform impedance-based stability analysis for the operation of grid-connected systems, such as power electronics-interfaced solar, wind and other distributed power generation systems. The identification of grid impedance with the help of broadband signals is a popular method, but its robustness depends strongly on the harmonic disturbances caused by non-linear loads or power electronics. This paper provides an in-depth analysis of how harmonics affect the identification of grid impedance while using broadband measurements. Furthermore, a compensation method is proposed to remove the disturbing influences of harmonics on broadband impedance identification. This method is based on exploiting the properties of the used maximum-length binary sequence (MLBS). To explain the methodology of the proposed method, the design basis for the excitation signal is discussed in detail. The analysis from simulations and a real measurement in an industrial power grid shows the effectiveness of the proposed method in compensating the disturbing influences of harmonics on broadband impedance measurements.
format article
author Matthias Buchner
Krzysztof Rudion
author_facet Matthias Buchner
Krzysztof Rudion
author_sort Matthias Buchner
title Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics
title_short Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics
title_full Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics
title_fullStr Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics
title_full_unstemmed Identification of Grid Impedance by Broadband Signals in Power Systems with High Harmonics
title_sort identification of grid impedance by broadband signals in power systems with high harmonics
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/2bd868410eba4b6f863805d7a4290b48
work_keys_str_mv AT matthiasbuchner identificationofgridimpedancebybroadbandsignalsinpowersystemswithhighharmonics
AT krzysztofrudion identificationofgridimpedancebybroadbandsignalsinpowersystemswithhighharmonics
_version_ 1718432403988414464