System introduction and evaluation of the first Chinese chest EIT device for ICU applications

Abstract Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Shuo-Yao Qu, Meng Dai, Shuo Wu, Zhi-Rang Lv, Xin-Yu Ti, Feng Fu
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/2c605c8d675f43939bf5b8f1dc956e61
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:2c605c8d675f43939bf5b8f1dc956e61
record_format dspace
spelling oai:doaj.org-article:2c605c8d675f43939bf5b8f1dc956e612021-12-02T19:16:54ZSystem introduction and evaluation of the first Chinese chest EIT device for ICU applications10.1038/s41598-021-98793-02045-2322https://doaj.org/article/2c605c8d675f43939bf5b8f1dc956e612021-09-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-98793-0https://doaj.org/toc/2045-2322Abstract Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting.Shuo-Yao QuMeng DaiShuo WuZhi-Rang LvXin-Yu TiFeng FuNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Shuo-Yao Qu
Meng Dai
Shuo Wu
Zhi-Rang Lv
Xin-Yu Ti
Feng Fu
System introduction and evaluation of the first Chinese chest EIT device for ICU applications
description Abstract Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting.
format article
author Shuo-Yao Qu
Meng Dai
Shuo Wu
Zhi-Rang Lv
Xin-Yu Ti
Feng Fu
author_facet Shuo-Yao Qu
Meng Dai
Shuo Wu
Zhi-Rang Lv
Xin-Yu Ti
Feng Fu
author_sort Shuo-Yao Qu
title System introduction and evaluation of the first Chinese chest EIT device for ICU applications
title_short System introduction and evaluation of the first Chinese chest EIT device for ICU applications
title_full System introduction and evaluation of the first Chinese chest EIT device for ICU applications
title_fullStr System introduction and evaluation of the first Chinese chest EIT device for ICU applications
title_full_unstemmed System introduction and evaluation of the first Chinese chest EIT device for ICU applications
title_sort system introduction and evaluation of the first chinese chest eit device for icu applications
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/2c605c8d675f43939bf5b8f1dc956e61
work_keys_str_mv AT shuoyaoqu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications
AT mengdai systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications
AT shuowu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications
AT zhiranglv systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications
AT xinyuti systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications
AT fengfu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications
_version_ 1718376904203960320