System introduction and evaluation of the first Chinese chest EIT device for ICU applications
Abstract Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2c605c8d675f43939bf5b8f1dc956e61 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:2c605c8d675f43939bf5b8f1dc956e61 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2c605c8d675f43939bf5b8f1dc956e612021-12-02T19:16:54ZSystem introduction and evaluation of the first Chinese chest EIT device for ICU applications10.1038/s41598-021-98793-02045-2322https://doaj.org/article/2c605c8d675f43939bf5b8f1dc956e612021-09-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-98793-0https://doaj.org/toc/2045-2322Abstract Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting.Shuo-Yao QuMeng DaiShuo WuZhi-Rang LvXin-Yu TiFeng FuNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Shuo-Yao Qu Meng Dai Shuo Wu Zhi-Rang Lv Xin-Yu Ti Feng Fu System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
description |
Abstract Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting. |
format |
article |
author |
Shuo-Yao Qu Meng Dai Shuo Wu Zhi-Rang Lv Xin-Yu Ti Feng Fu |
author_facet |
Shuo-Yao Qu Meng Dai Shuo Wu Zhi-Rang Lv Xin-Yu Ti Feng Fu |
author_sort |
Shuo-Yao Qu |
title |
System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_short |
System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_full |
System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_fullStr |
System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_full_unstemmed |
System introduction and evaluation of the first Chinese chest EIT device for ICU applications |
title_sort |
system introduction and evaluation of the first chinese chest eit device for icu applications |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/2c605c8d675f43939bf5b8f1dc956e61 |
work_keys_str_mv |
AT shuoyaoqu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT mengdai systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT shuowu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT zhiranglv systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT xinyuti systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications AT fengfu systemintroductionandevaluationofthefirstchinesechesteitdeviceforicuapplications |
_version_ |
1718376904203960320 |