Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology
Abstract Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced a...
Guardado en:
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2ce30147b9f840c3abd2b3a62987eb09 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:2ce30147b9f840c3abd2b3a62987eb09 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2ce30147b9f840c3abd2b3a62987eb092021-12-02T15:10:02ZEstimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology10.1038/s41598-019-50529-x2045-2322https://doaj.org/article/2ce30147b9f840c3abd2b3a62987eb092019-10-01T00:00:00Zhttps://doi.org/10.1038/s41598-019-50529-xhttps://doaj.org/toc/2045-2322Abstract Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced and unenhanced CT examinations were randomly assigned to development and validation groups. The enhanced CT-measured arterial phase and the venous phase images of kidneys were regarded as the true values for cortical volume and parenchymal volume, respectively. Linear multiple regression analysis was used to create models for estimating cortical volume using explanatory variables including unenhanced CT-measured parenchymal volume. Nephron number was determined as the product of cortical volume and the glomerular density in biopsies of donors. Five equations for estimating cortical volume were created and verified. In donors, estimated nephron number by unenhanced CT was consistent with that by enhanced CT, with minimal errors in all models (636–655 ± 210–219 vs. 648 ± 224 × 103/kidney). Clinical characteristics combined with parenchymal volume did not improve the equation over parenchymal volume alone. These results support the feasibility of estimating nephron number by a combination of unenhanced CT and biopsy-based stereology, with a possible application for renal disease patients who are often not suitable for contrast media.Takaya SasakiNobuo TsuboiYusuke OkabayashiKotaro HaruharaGo KanzakiKentaro KoikeAkimitsu KobayashiIzumi YamamotoSho TakahashiToshiharu NinomiyaAkira ShimizuAndrew D. RuleJohn F. BertramTakashi YokooNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 9, Iss 1, Pp 1-10 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Takaya Sasaki Nobuo Tsuboi Yusuke Okabayashi Kotaro Haruhara Go Kanzaki Kentaro Koike Akimitsu Kobayashi Izumi Yamamoto Sho Takahashi Toshiharu Ninomiya Akira Shimizu Andrew D. Rule John F. Bertram Takashi Yokoo Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
description |
Abstract Methods for estimating nephron number in a clinical setting may be useful for predicting renal outcomes. This study aimed to establish such a method using unenhanced computed tomography (CT) and biopsy-based stereology. Patients or living kidney donors simultaneously subjected to enhanced and unenhanced CT examinations were randomly assigned to development and validation groups. The enhanced CT-measured arterial phase and the venous phase images of kidneys were regarded as the true values for cortical volume and parenchymal volume, respectively. Linear multiple regression analysis was used to create models for estimating cortical volume using explanatory variables including unenhanced CT-measured parenchymal volume. Nephron number was determined as the product of cortical volume and the glomerular density in biopsies of donors. Five equations for estimating cortical volume were created and verified. In donors, estimated nephron number by unenhanced CT was consistent with that by enhanced CT, with minimal errors in all models (636–655 ± 210–219 vs. 648 ± 224 × 103/kidney). Clinical characteristics combined with parenchymal volume did not improve the equation over parenchymal volume alone. These results support the feasibility of estimating nephron number by a combination of unenhanced CT and biopsy-based stereology, with a possible application for renal disease patients who are often not suitable for contrast media. |
format |
article |
author |
Takaya Sasaki Nobuo Tsuboi Yusuke Okabayashi Kotaro Haruhara Go Kanzaki Kentaro Koike Akimitsu Kobayashi Izumi Yamamoto Sho Takahashi Toshiharu Ninomiya Akira Shimizu Andrew D. Rule John F. Bertram Takashi Yokoo |
author_facet |
Takaya Sasaki Nobuo Tsuboi Yusuke Okabayashi Kotaro Haruhara Go Kanzaki Kentaro Koike Akimitsu Kobayashi Izumi Yamamoto Sho Takahashi Toshiharu Ninomiya Akira Shimizu Andrew D. Rule John F. Bertram Takashi Yokoo |
author_sort |
Takaya Sasaki |
title |
Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
title_short |
Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
title_full |
Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
title_fullStr |
Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
title_full_unstemmed |
Estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
title_sort |
estimation of nephron number in living humans by combining unenhanced computed tomography with biopsy-based stereology |
publisher |
Nature Portfolio |
publishDate |
2019 |
url |
https://doaj.org/article/2ce30147b9f840c3abd2b3a62987eb09 |
work_keys_str_mv |
AT takayasasaki estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT nobuotsuboi estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT yusukeokabayashi estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT kotaroharuhara estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT gokanzaki estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT kentarokoike estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT akimitsukobayashi estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT izumiyamamoto estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT shotakahashi estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT toshiharuninomiya estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT akirashimizu estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT andrewdrule estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT johnfbertram estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology AT takashiyokoo estimationofnephronnumberinlivinghumansbycombiningunenhancedcomputedtomographywithbiopsybasedstereology |
_version_ |
1718387741877600256 |