Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution
Catherine A Scheuer, Marjorie J Rah, William T Reindel Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA Purpose: This study was conducted to determine 1) the concentration of hyaluronan (HA) in the tear films of contact lens (CL) wearers versus non-CL wearers and 2) whether HA s...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://doaj.org/article/2e83a71eae114de9b2b73ba743ec13c7 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:2e83a71eae114de9b2b73ba743ec13c7 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2e83a71eae114de9b2b73ba743ec13c72021-12-02T00:02:42ZIncreased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution1177-5483https://doaj.org/article/2e83a71eae114de9b2b73ba743ec13c72016-10-01T00:00:00Zhttps://www.dovepress.com/increased-concentration-of-hyaluronan-in-tears-after-soaking-contact-l-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Catherine A Scheuer, Marjorie J Rah, William T Reindel Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA Purpose: This study was conducted to determine 1) the concentration of hyaluronan (HA) in the tear films of contact lens (CL) wearers versus non-CL wearers and 2) whether HA sorbed from Biotrue, an HA-containing multipurpose solution (MPS), onto senofilcon A lenses affects the concentration of HA in tears after 2 hours of wear.Patients and methods: Tears of habitual CL wearers and non-CL wearers were collected on Schirmer strips at baseline and after 2 hours of wear of senofilcon A CLs that had first been either rinsed with Sensitive Eyes Saline or soaked in Biotrue MPS for 14 hours. HA concentrations were measured by enzyme-linked immunosorbent assay (ELISA) and adjusted for sample volumes.Results: No difference in baseline concentrations of HA in tears was found between CL wearers and non-CL wearers (P=0.07), nor between males and females (P=0.06). However, age was significantly negatively associated with HA concentration (P<0.01), and mostly, CL wear contributed to a significant association (P<0.01). Among saline-rinsed CL wearers, no change in HA concentration in tears was observed after 2 hours of wear (P=0.38). By contrast, a significant increase in HA concentration was observed in the tears from eyes that had worn CLs soaked in Biotrue MPS when compared to baseline (P=0.01) or to saline-rinsed control (P=0.03).Conclusion: 1) In this study population, no difference in baseline concentration of HA was observed between CL wearers and non-CL wearers, and 2) after 2 hours of wear of senofilcon A lenses that were soaked in Biotrue MPS, HA concentrations in the tear films of CL wearers increased. Keywords: contact lens, dry eye, hyaluronan, MPSScheuer CARah MJReindel WTDove Medical Pressarticlecontact lensdry eyehyaluronanMPSOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 10, Pp 1945-1952 (2016) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
contact lens dry eye hyaluronan MPS Ophthalmology RE1-994 |
spellingShingle |
contact lens dry eye hyaluronan MPS Ophthalmology RE1-994 Scheuer CA Rah MJ Reindel WT Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution |
description |
Catherine A Scheuer, Marjorie J Rah, William T Reindel Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA Purpose: This study was conducted to determine 1) the concentration of hyaluronan (HA) in the tear films of contact lens (CL) wearers versus non-CL wearers and 2) whether HA sorbed from Biotrue, an HA-containing multipurpose solution (MPS), onto senofilcon A lenses affects the concentration of HA in tears after 2 hours of wear.Patients and methods: Tears of habitual CL wearers and non-CL wearers were collected on Schirmer strips at baseline and after 2 hours of wear of senofilcon A CLs that had first been either rinsed with Sensitive Eyes Saline or soaked in Biotrue MPS for 14 hours. HA concentrations were measured by enzyme-linked immunosorbent assay (ELISA) and adjusted for sample volumes.Results: No difference in baseline concentrations of HA in tears was found between CL wearers and non-CL wearers (P=0.07), nor between males and females (P=0.06). However, age was significantly negatively associated with HA concentration (P<0.01), and mostly, CL wear contributed to a significant association (P<0.01). Among saline-rinsed CL wearers, no change in HA concentration in tears was observed after 2 hours of wear (P=0.38). By contrast, a significant increase in HA concentration was observed in the tears from eyes that had worn CLs soaked in Biotrue MPS when compared to baseline (P=0.01) or to saline-rinsed control (P=0.03).Conclusion: 1) In this study population, no difference in baseline concentration of HA was observed between CL wearers and non-CL wearers, and 2) after 2 hours of wear of senofilcon A lenses that were soaked in Biotrue MPS, HA concentrations in the tear films of CL wearers increased. Keywords: contact lens, dry eye, hyaluronan, MPS |
format |
article |
author |
Scheuer CA Rah MJ Reindel WT |
author_facet |
Scheuer CA Rah MJ Reindel WT |
author_sort |
Scheuer CA |
title |
Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution |
title_short |
Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution |
title_full |
Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution |
title_fullStr |
Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution |
title_full_unstemmed |
Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution |
title_sort |
increased concentration of hyaluronan in tears after soaking contact lenses in biotrue multipurpose solution |
publisher |
Dove Medical Press |
publishDate |
2016 |
url |
https://doaj.org/article/2e83a71eae114de9b2b73ba743ec13c7 |
work_keys_str_mv |
AT scheuerca increasedconcentrationofhyaluronanintearsaftersoakingcontactlensesinbiotruemultipurposesolution AT rahmj increasedconcentrationofhyaluronanintearsaftersoakingcontactlensesinbiotruemultipurposesolution AT reindelwt increasedconcentrationofhyaluronanintearsaftersoakingcontactlensesinbiotruemultipurposesolution |
_version_ |
1718403974511460352 |