Aortic stiffness in lone atrial fibrillation: a novel risk factor for arrhythmia recurrence.

<h4>Background</h4>Recent community-based research has linked aortic stiffness to the development of atrial fibrillation. We posit that aortic stiffness contributes to adverse atrial remodeling leading to the persistence of atrial fibrillation following catheter ablation in lone atrial f...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dennis H Lau, Melissa E Middeldorp, Anthony G Brooks, Anand N Ganesan, Kurt C Roberts-Thomson, Martin K Stiles, Darryl P Leong, Hany S Abed, Han S Lim, Christopher X Wong, Scott R Willoughby, Glenn D Young, Jonathan M Kalman, Walter P Abhayaratna, Prashanthan Sanders
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2013
Materias:
R
Q
Acceso en línea:https://doaj.org/article/2ee4a37d6b7b48dea0cba634a2d53988
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:<h4>Background</h4>Recent community-based research has linked aortic stiffness to the development of atrial fibrillation. We posit that aortic stiffness contributes to adverse atrial remodeling leading to the persistence of atrial fibrillation following catheter ablation in lone atrial fibrillation patients, despite the absence of apparent structural heart disease. Here, we aim to evaluate aortic stiffness in lone atrial fibrillation patients and determine its association with arrhythmia recurrence following radio-frequency catheter ablation.<h4>Methods</h4>We studied 68 consecutive lone atrial fibrillation patients who underwent catheter ablation procedure for atrial fibrillation and 50 healthy age- and sex-matched community controls. We performed radial artery applanation tonometry to obtain central measures of aortic stiffness: pulse pressure, augmentation pressure and augmentation index. Following ablation, arrhythmia recurrence was monitored at months 3, 6, 9, 12 and 6 monthly thereafter.<h4>Results</h4>Compared to healthy controls, lone atrial fibrillation patients had significantly elevated peripheral pulse pressure, central pulse pressure, augmentation pressure and larger left atrial dimensions (all P<0.05). During a mean follow-up of 2.9±1.4 years, 38 of the 68 lone atrial fibrillation patients had atrial fibrillation recurrence after initial catheter ablation procedure. Neither blood pressure nor aortic stiffness indices differed between patients with and without atrial fibrillation recurrence. However, patients with highest levels (≥75(th) percentile) of peripheral pulse pressure, central pulse pressure and augmentation pressure had higher atrial fibrillation recurrence rates (all P<0.05). Only central aortic stiffness indices were associated with lower survival free from atrial fibrillation using Kaplan-Meier analysis.<h4>Conclusion</h4>Aortic stiffness is an important risk factor in patients with lone atrial fibrillation and contributes to higher atrial fibrillation recurrence following catheter ablation procedure.