ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION
An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which...
Saved in:
Main Authors: | , |
---|---|
Format: | article |
Language: | EN RU UK |
Published: |
National Technical University "Kharkiv Polytechnic Institute"
2014
|
Subjects: | |
Online Access: | https://doaj.org/article/2f8b5e7c664d4139a464bef201f6f79c |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:doaj.org-article:2f8b5e7c664d4139a464bef201f6f79c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:2f8b5e7c664d4139a464bef201f6f79c2021-12-02T17:51:12ZANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION2074-272X2074-272Xhttps://doaj.org/article/2f8b5e7c664d4139a464bef201f6f79c2014-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/34794/31015https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2074-272XAn analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which are used for technical diagnostics of insulation.A.V. BezprozvannychA.G. KyessaeyvNational Technical University "Kharkiv Polytechnic Institute"articlepartial dischargeelectrostatic fieldtwisted shielded pairtest voltagesymmetric bipolarunipolar and asymmetricselective diagnosticsElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 61-65 (2014) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
partial discharge electrostatic field twisted shielded pair test voltage symmetric bipolar unipolar and asymmetric selective diagnostics Electrical engineering. Electronics. Nuclear engineering TK1-9971 A.V. Bezprozvannych A.G. Kyessaeyv ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
description |
An analysis of the electrostatic field of a cable twisted shielded pair for various types of test voltage: symmetric bipolar, unipolar and asymmetric is carried out. Voltage selection affects the location of the most probable place of arising of the partial discharges, phase characteristics of which are used for technical diagnostics of insulation. |
format |
article |
author |
A.V. Bezprozvannych A.G. Kyessaeyv |
author_facet |
A.V. Bezprozvannych A.G. Kyessaeyv |
author_sort |
A.V. Bezprozvannych |
title |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
title_short |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
title_full |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
title_fullStr |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
title_full_unstemmed |
ANALYSIS OF FIELD STRUCTURE AND JUSTIFICATION OF VOLTAGES OF DIAGNOSTICS BY PARTIAL DISCHARGES OF SHIELDED TWISTED PAIRS INSULATION |
title_sort |
analysis of field structure and justification of voltages of diagnostics by partial discharges of shielded twisted pairs insulation |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2014 |
url |
https://doaj.org/article/2f8b5e7c664d4139a464bef201f6f79c |
work_keys_str_mv |
AT avbezprozvannych analysisoffieldstructureandjustificationofvoltagesofdiagnosticsbypartialdischargesofshieldedtwistedpairsinsulation AT agkyessaeyv analysisoffieldstructureandjustificationofvoltagesofdiagnosticsbypartialdischargesofshieldedtwistedpairsinsulation |
_version_ |
1718379276208701440 |