Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications

The 60 GHz band is a great prospect to meet the future demand for short-range indoor communication requiring wide bandwidth and high data rates. This paper presents the design of a 60 GHz printed Q-slot patch antenna for body-centric communication. The Q-slot has a slot gap of 0.2 mm and is etched o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mohammad Monirujjaman Khan, Kaisarul Islam, Md. Nakib Alam Shovon, Mohammed Baz, Mehedi Masud
Formato: article
Lenguaje:EN
Publicado: Hindawi Limited 2021
Materias:
Acceso en línea:https://doaj.org/article/308239ab6f7741e7abbd605fe57d5643
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:308239ab6f7741e7abbd605fe57d5643
record_format dspace
spelling oai:doaj.org-article:308239ab6f7741e7abbd605fe57d56432021-11-15T01:19:01ZDesign of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications1687-587710.1155/2021/9795959https://doaj.org/article/308239ab6f7741e7abbd605fe57d56432021-01-01T00:00:00Zhttp://dx.doi.org/10.1155/2021/9795959https://doaj.org/toc/1687-5877The 60 GHz band is a great prospect to meet the future demand for short-range indoor communication requiring wide bandwidth and high data rates. This paper presents the design of a 60 GHz printed Q-slot patch antenna for body-centric communication. The Q-slot has a slot gap of 0.2 mm and is etched on a 6.5 mm × 11 mm rectangular patch. The slotted patch is mounted on an FR-4 (Flame Retardant) substrate that is 1.6 mm thick and has a relative permittivity of 4.3. With a partial ground plane of length of 2.2 mm, the antenna’s overall dimension is 12.9 mm × 14 mm × 1.6 mm. Computer Simulation Technology (CST) microwave studio was used to design and simulate the antenna. In free space, the antenna is resonant at 60.06 GHz with an impedance bandwidth of 12.11 GHz. At 60 GHz, the antenna’s radiation efficiency is 82.15%, with a maximum gain of 8.62 dBi. For further analysis, parametric changes were made to observe the effect on return loss, radiation efficiency, and gain. The antenna was simulated on a three-layer human torso phantom for the on-body scenario. The antenna’s resonant frequency shifted slightly to the right at 2 mm distant from the phantom while maintaining a very wide impedance bandwidth. At this point, the antenna’s radiation efficiency dropped to 56.68% and gradually increased to 74.04% at 10 mm. The maximum gain remained largely unaffected, but some grated radiation patterns were observed.Mohammad Monirujjaman KhanKaisarul IslamMd. Nakib Alam ShovonMohammed BazMehedi MasudHindawi LimitedarticleElectrical engineering. Electronics. Nuclear engineeringTK1-9971Cellular telephone services industry. Wireless telephone industryHE9713-9715ENInternational Journal of Antennas and Propagation, Vol 2021 (2021)
institution DOAJ
collection DOAJ
language EN
topic Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Cellular telephone services industry. Wireless telephone industry
HE9713-9715
spellingShingle Electrical engineering. Electronics. Nuclear engineering
TK1-9971
Cellular telephone services industry. Wireless telephone industry
HE9713-9715
Mohammad Monirujjaman Khan
Kaisarul Islam
Md. Nakib Alam Shovon
Mohammed Baz
Mehedi Masud
Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications
description The 60 GHz band is a great prospect to meet the future demand for short-range indoor communication requiring wide bandwidth and high data rates. This paper presents the design of a 60 GHz printed Q-slot patch antenna for body-centric communication. The Q-slot has a slot gap of 0.2 mm and is etched on a 6.5 mm × 11 mm rectangular patch. The slotted patch is mounted on an FR-4 (Flame Retardant) substrate that is 1.6 mm thick and has a relative permittivity of 4.3. With a partial ground plane of length of 2.2 mm, the antenna’s overall dimension is 12.9 mm × 14 mm × 1.6 mm. Computer Simulation Technology (CST) microwave studio was used to design and simulate the antenna. In free space, the antenna is resonant at 60.06 GHz with an impedance bandwidth of 12.11 GHz. At 60 GHz, the antenna’s radiation efficiency is 82.15%, with a maximum gain of 8.62 dBi. For further analysis, parametric changes were made to observe the effect on return loss, radiation efficiency, and gain. The antenna was simulated on a three-layer human torso phantom for the on-body scenario. The antenna’s resonant frequency shifted slightly to the right at 2 mm distant from the phantom while maintaining a very wide impedance bandwidth. At this point, the antenna’s radiation efficiency dropped to 56.68% and gradually increased to 74.04% at 10 mm. The maximum gain remained largely unaffected, but some grated radiation patterns were observed.
format article
author Mohammad Monirujjaman Khan
Kaisarul Islam
Md. Nakib Alam Shovon
Mohammed Baz
Mehedi Masud
author_facet Mohammad Monirujjaman Khan
Kaisarul Islam
Md. Nakib Alam Shovon
Mohammed Baz
Mehedi Masud
author_sort Mohammad Monirujjaman Khan
title Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications
title_short Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications
title_full Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications
title_fullStr Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications
title_full_unstemmed Design of a Novel 60 GHz Millimeter Wave Q-Slot Antenna for Body-Centric Communications
title_sort design of a novel 60 ghz millimeter wave q-slot antenna for body-centric communications
publisher Hindawi Limited
publishDate 2021
url https://doaj.org/article/308239ab6f7741e7abbd605fe57d5643
work_keys_str_mv AT mohammadmonirujjamankhan designofanovel60ghzmillimeterwaveqslotantennaforbodycentriccommunications
AT kaisarulislam designofanovel60ghzmillimeterwaveqslotantennaforbodycentriccommunications
AT mdnakibalamshovon designofanovel60ghzmillimeterwaveqslotantennaforbodycentriccommunications
AT mohammedbaz designofanovel60ghzmillimeterwaveqslotantennaforbodycentriccommunications
AT mehedimasud designofanovel60ghzmillimeterwaveqslotantennaforbodycentriccommunications
_version_ 1718428973566787584