Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture

Abstract This study aimed to analyze the reproducibility and reliability of the alignment parameters measured using the EOS image system in both limbs while standing with an even weight-bearing posture. Overall, 104 lower extremities in 52 patients were analyzed retrospectively. The patients stood w...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Byung Woo Cho, Tae-Ho Lee, Sungjun Kim, Chong-Hyuk Choi, Min Jung, Koo Yeon Lee, Sung-Hwan Kim
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/30e55ee772cd4c31afd473de217bf6ae
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:30e55ee772cd4c31afd473de217bf6ae
record_format dspace
spelling oai:doaj.org-article:30e55ee772cd4c31afd473de217bf6ae2021-11-14T12:22:06ZEvaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture10.1038/s41598-021-01646-z2045-2322https://doaj.org/article/30e55ee772cd4c31afd473de217bf6ae2021-11-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-01646-zhttps://doaj.org/toc/2045-2322Abstract This study aimed to analyze the reproducibility and reliability of the alignment parameters measured using the EOS image system in both limbs while standing with an even weight-bearing posture. Overall, 104 lower extremities in 52 patients were analyzed retrospectively. The patients stood with an even load over both lower extremities then rotated 15° in both directions. Two EOS images were acquired and 104 pairs of lower extremities were compared according to the position of the indexed lower extremities. Then, the inter-observer reliability of the EOS system and the inter-modality reliability between EOS and computed tomography (CT) were evaluated. Femoro-tibial rotation (FTR) and tibial torsion demonstrated a significant difference between the anterior and posterior positions of the indexed lower extremity. In the inter-observer reliability analysis, all values except for FTR and tibial torsion demonstrated good or very good reliability. In the anterior position, FTR demonstrated moderate, and tibial torsion demonstrated poor reliability. In the posterior position, both FTR and tibial torsion demonstrated poor reliability. In the reliability analysis between the three-dimensional (3D) EOS model and 3D CT images, all measurements of the femur demonstrated very good reliability, but measurements of the tibia did not. For the coronal and sagittal alignment parameters measured by the EOS 3D system with rotated standing posture, except for the measurement including tibial torsion., there were no significant difference for either position of the indexed extremities with high agreement between the observers as well as with the CT 3D model.Byung Woo ChoTae-Ho LeeSungjun KimChong-Hyuk ChoiMin JungKoo Yeon LeeSung-Hwan KimNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-10 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Byung Woo Cho
Tae-Ho Lee
Sungjun Kim
Chong-Hyuk Choi
Min Jung
Koo Yeon Lee
Sung-Hwan Kim
Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture
description Abstract This study aimed to analyze the reproducibility and reliability of the alignment parameters measured using the EOS image system in both limbs while standing with an even weight-bearing posture. Overall, 104 lower extremities in 52 patients were analyzed retrospectively. The patients stood with an even load over both lower extremities then rotated 15° in both directions. Two EOS images were acquired and 104 pairs of lower extremities were compared according to the position of the indexed lower extremities. Then, the inter-observer reliability of the EOS system and the inter-modality reliability between EOS and computed tomography (CT) were evaluated. Femoro-tibial rotation (FTR) and tibial torsion demonstrated a significant difference between the anterior and posterior positions of the indexed lower extremity. In the inter-observer reliability analysis, all values except for FTR and tibial torsion demonstrated good or very good reliability. In the anterior position, FTR demonstrated moderate, and tibial torsion demonstrated poor reliability. In the posterior position, both FTR and tibial torsion demonstrated poor reliability. In the reliability analysis between the three-dimensional (3D) EOS model and 3D CT images, all measurements of the femur demonstrated very good reliability, but measurements of the tibia did not. For the coronal and sagittal alignment parameters measured by the EOS 3D system with rotated standing posture, except for the measurement including tibial torsion., there were no significant difference for either position of the indexed extremities with high agreement between the observers as well as with the CT 3D model.
format article
author Byung Woo Cho
Tae-Ho Lee
Sungjun Kim
Chong-Hyuk Choi
Min Jung
Koo Yeon Lee
Sung-Hwan Kim
author_facet Byung Woo Cho
Tae-Ho Lee
Sungjun Kim
Chong-Hyuk Choi
Min Jung
Koo Yeon Lee
Sung-Hwan Kim
author_sort Byung Woo Cho
title Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture
title_short Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture
title_full Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture
title_fullStr Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture
title_full_unstemmed Evaluation of the reliability of lower extremity alignment measurements using EOS imaging system while standing in an even weight-bearing posture
title_sort evaluation of the reliability of lower extremity alignment measurements using eos imaging system while standing in an even weight-bearing posture
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/30e55ee772cd4c31afd473de217bf6ae
work_keys_str_mv AT byungwoocho evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
AT taeholee evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
AT sungjunkim evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
AT chonghyukchoi evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
AT minjung evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
AT kooyeonlee evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
AT sunghwankim evaluationofthereliabilityoflowerextremityalignmentmeasurementsusingeosimagingsystemwhilestandinginanevenweightbearingposture
_version_ 1718429218568667136