Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin
The spins of nitrogen vacancy centres have been shown to be sensitive, high-temperature quantum probes of magnetic fields but the usual readout scheme fails above 550 K. Here the authors demonstrate coherent control and sensing up to 1000 K by using fast temperature control to reach the conditions f...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/3118d4d5b7ea416ab876bf4a7d824304 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:3118d4d5b7ea416ab876bf4a7d824304 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:3118d4d5b7ea416ab876bf4a7d8243042021-12-02T14:35:56ZCoherent quantum control of nitrogen-vacancy center spins near 1000 kelvin10.1038/s41467-019-09327-22041-1723https://doaj.org/article/3118d4d5b7ea416ab876bf4a7d8243042019-03-01T00:00:00Zhttps://doi.org/10.1038/s41467-019-09327-2https://doaj.org/toc/2041-1723The spins of nitrogen vacancy centres have been shown to be sensitive, high-temperature quantum probes of magnetic fields but the usual readout scheme fails above 550 K. Here the authors demonstrate coherent control and sensing up to 1000 K by using fast temperature control to reach the conditions for readout.Gang-Qin LiuXi FengNing WangQuan LiRen-Bao LiuNature PortfolioarticleScienceQENNature Communications, Vol 10, Iss 1, Pp 1-8 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Science Q |
spellingShingle |
Science Q Gang-Qin Liu Xi Feng Ning Wang Quan Li Ren-Bao Liu Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
description |
The spins of nitrogen vacancy centres have been shown to be sensitive, high-temperature quantum probes of magnetic fields but the usual readout scheme fails above 550 K. Here the authors demonstrate coherent control and sensing up to 1000 K by using fast temperature control to reach the conditions for readout. |
format |
article |
author |
Gang-Qin Liu Xi Feng Ning Wang Quan Li Ren-Bao Liu |
author_facet |
Gang-Qin Liu Xi Feng Ning Wang Quan Li Ren-Bao Liu |
author_sort |
Gang-Qin Liu |
title |
Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
title_short |
Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
title_full |
Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
title_fullStr |
Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
title_full_unstemmed |
Coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
title_sort |
coherent quantum control of nitrogen-vacancy center spins near 1000 kelvin |
publisher |
Nature Portfolio |
publishDate |
2019 |
url |
https://doaj.org/article/3118d4d5b7ea416ab876bf4a7d824304 |
work_keys_str_mv |
AT gangqinliu coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin AT xifeng coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin AT ningwang coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin AT quanli coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin AT renbaoliu coherentquantumcontrolofnitrogenvacancycenterspinsnear1000kelvin |
_version_ |
1718390999636508672 |