Dynamic contour tonometry in asymmetric glaucoma patients
Emilio Rintaro Suzuki Jr1, Cibele Lima Belico Suzuki1, Danielle Carlier1, Daniele Penha1, Marta dos Anjos Rodrigues Parchen1, Wagner Duarte Batista1, Joao Agostini Netto21Glaucoma Service, 2Department of Ophthalmology, Santa Casa de Belo Horizonte, MG, BrazilBackground: The purpose of this study was...
Guardado en:
Autores principales: | , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://doaj.org/article/316a1609cdf94e4bb8de7e5954e36edf |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:316a1609cdf94e4bb8de7e5954e36edf |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:316a1609cdf94e4bb8de7e5954e36edf2021-12-02T04:21:03ZDynamic contour tonometry in asymmetric glaucoma patients1177-54671177-5483https://doaj.org/article/316a1609cdf94e4bb8de7e5954e36edf2012-04-01T00:00:00Zhttp://www.dovepress.com/dynamic-contour-tonometry-in-asymmetric-glaucoma-patients-a9674https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Emilio Rintaro Suzuki Jr1, Cibele Lima Belico Suzuki1, Danielle Carlier1, Daniele Penha1, Marta dos Anjos Rodrigues Parchen1, Wagner Duarte Batista1, Joao Agostini Netto21Glaucoma Service, 2Department of Ophthalmology, Santa Casa de Belo Horizonte, MG, BrazilBackground: The purpose of this study was to determine any difference in dynamic contour tonometry and ocular pulse amplitude in asymmetric glaucoma patients with the same applanation intraocular pressure.Methods: This is a prospective, observational study of 30 glaucoma patients and 11 controls from June 2007 to February 2008. Most of the glaucoma patients were on prostaglandin analog treatment.Results: Mean applanation intraocular pressure in the control group was 14.28 mmHg for the right eye and 14.10 mmHg for the left eye (P > 0.05). Corneal thickness was 519.10 µm for the right eye and 511.07 µm for the left eye (P > 0.05). Mean dynamic contour tonometry intraocular pressure was 17.28 mmHg for the right eye and 17.25 mmHg for the left eye (P > 0.05). Mean ocular pulse amplitude was 2.80 mmHg for the right eye and 2.92 mmHg for the left eye (P > 0.05).Conclusion: No differences in ocular pulse amplitude were found between the two groups and between the worst and the best eye. In spite of there being no difference in ocular pulse amplitude, dynamic contour tonometry intraocular pressure was 2.44 mmHg higher in the worst eye than in the best eye in the glaucoma patients, even with the same applanation intraocular pressure. Further studies are needed to confirm if this difference is related to glaucoma progression or a worst prognosis and whether it can be considered to be a new risk factor.Keywords: dynamic contour tonometry, central cornea thickness, assymetric glaucomaParchen MARPenha DAgostini Netto JBatista WDCarlier DSuzuki CLBSuzuki Jr ERDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2012, Iss default, Pp 555-559 (2012) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Parchen MAR Penha D Agostini Netto J Batista WD Carlier D Suzuki CLB Suzuki Jr ER Dynamic contour tonometry in asymmetric glaucoma patients |
description |
Emilio Rintaro Suzuki Jr1, Cibele Lima Belico Suzuki1, Danielle Carlier1, Daniele Penha1, Marta dos Anjos Rodrigues Parchen1, Wagner Duarte Batista1, Joao Agostini Netto21Glaucoma Service, 2Department of Ophthalmology, Santa Casa de Belo Horizonte, MG, BrazilBackground: The purpose of this study was to determine any difference in dynamic contour tonometry and ocular pulse amplitude in asymmetric glaucoma patients with the same applanation intraocular pressure.Methods: This is a prospective, observational study of 30 glaucoma patients and 11 controls from June 2007 to February 2008. Most of the glaucoma patients were on prostaglandin analog treatment.Results: Mean applanation intraocular pressure in the control group was 14.28 mmHg for the right eye and 14.10 mmHg for the left eye (P > 0.05). Corneal thickness was 519.10 µm for the right eye and 511.07 µm for the left eye (P > 0.05). Mean dynamic contour tonometry intraocular pressure was 17.28 mmHg for the right eye and 17.25 mmHg for the left eye (P > 0.05). Mean ocular pulse amplitude was 2.80 mmHg for the right eye and 2.92 mmHg for the left eye (P > 0.05).Conclusion: No differences in ocular pulse amplitude were found between the two groups and between the worst and the best eye. In spite of there being no difference in ocular pulse amplitude, dynamic contour tonometry intraocular pressure was 2.44 mmHg higher in the worst eye than in the best eye in the glaucoma patients, even with the same applanation intraocular pressure. Further studies are needed to confirm if this difference is related to glaucoma progression or a worst prognosis and whether it can be considered to be a new risk factor.Keywords: dynamic contour tonometry, central cornea thickness, assymetric glaucoma |
format |
article |
author |
Parchen MAR Penha D Agostini Netto J Batista WD Carlier D Suzuki CLB Suzuki Jr ER |
author_facet |
Parchen MAR Penha D Agostini Netto J Batista WD Carlier D Suzuki CLB Suzuki Jr ER |
author_sort |
Parchen MAR |
title |
Dynamic contour tonometry in asymmetric glaucoma patients |
title_short |
Dynamic contour tonometry in asymmetric glaucoma patients |
title_full |
Dynamic contour tonometry in asymmetric glaucoma patients |
title_fullStr |
Dynamic contour tonometry in asymmetric glaucoma patients |
title_full_unstemmed |
Dynamic contour tonometry in asymmetric glaucoma patients |
title_sort |
dynamic contour tonometry in asymmetric glaucoma patients |
publisher |
Dove Medical Press |
publishDate |
2012 |
url |
https://doaj.org/article/316a1609cdf94e4bb8de7e5954e36edf |
work_keys_str_mv |
AT parchenmar dynamiccontourtonometryinasymmetricglaucomapatients AT penhad dynamiccontourtonometryinasymmetricglaucomapatients AT agostininettoj dynamiccontourtonometryinasymmetricglaucomapatients AT batistawd dynamiccontourtonometryinasymmetricglaucomapatients AT carlierd dynamiccontourtonometryinasymmetricglaucomapatients AT suzukiclb dynamiccontourtonometryinasymmetricglaucomapatients AT suzukijrer dynamiccontourtonometryinasymmetricglaucomapatients |
_version_ |
1718401302569943040 |