Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler

This study aims to create a system that can monitor gas cylinders where this device consists of two systems, the first is a system to measure the weight of 3kg LPG gas cylinders to find the remaining gas which will then be displayed on the LCD, and the second the system gives a notification (alarm)...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Anisha Fadia Haya, Werman Kasoep, Nefy Puteri Novani
Formato: article
Lenguaje:EN
ID
Publicado: Universitas Andalas 2020
Materias:
Acceso en línea:https://doaj.org/article/3209a01974f642f484ebd8bddf8411ea
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:3209a01974f642f484ebd8bddf8411ea
record_format dspace
spelling oai:doaj.org-article:3209a01974f642f484ebd8bddf8411ea2021-11-22T08:47:47ZRancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler10.25077/chipset.1.02.61-68.20202722-4422https://doaj.org/article/3209a01974f642f484ebd8bddf8411ea2020-10-01T00:00:00Zhttp://chipset.fti.unand.ac.id/index.php/chipset/article/view/27https://doaj.org/toc/2722-4422 This study aims to create a system that can monitor gas cylinders where this device consists of two systems, the first is a system to measure the weight of 3kg LPG gas cylinders to find the remaining gas which will then be displayed on the LCD, and the second the system gives a notification (alarm) if there is a gas leak via SMS. This system consists of Arduino UNO Microcontroller components, Load cell Sensor, MQ-6 Sensor, and SIM800L GSM Module. For overall system testing, the load cell sensor system can display a percentage of the weight value obtained an error rate of 0%, this indicates that the formula used in the program runs according to what is desired. In the MQ-6 sensor system can make the buzzer on at a value >= 700 ppm, the results of the buzzer can live when the detected gas value >= 700 ppm, this is as desired. In the sim800L gsm module system can send leak notifications, the results obtained that the module can send SMS notifications. And the system turns on the buzzer when the LPG gas has reached the minimum limit, the results obtained by the buzzer will sound when the remaining gas value <= 16%. Based on tests conducted on this system the system can measure the desired weight of the cylinder to look for the remaining gas in the form of a percentage and detect a gas leak and then send an SMS notification. Anisha Fadia HayaWerman KasoepNefy Puteri NovaniUniversitas AndalasarticleArduino UnoLoad Cell SensorMQ-6 SensorSIM800L GSM ModuleMonitoringComputer softwareQA76.75-76.765Computer engineering. Computer hardwareTK7885-7895ENIDCHIPSET, Vol 1, Iss 02 (2020)
institution DOAJ
collection DOAJ
language EN
ID
topic Arduino Uno
Load Cell Sensor
MQ-6 Sensor
SIM800L GSM Module
Monitoring
Computer software
QA76.75-76.765
Computer engineering. Computer hardware
TK7885-7895
spellingShingle Arduino Uno
Load Cell Sensor
MQ-6 Sensor
SIM800L GSM Module
Monitoring
Computer software
QA76.75-76.765
Computer engineering. Computer hardware
TK7885-7895
Anisha Fadia Haya
Werman Kasoep
Nefy Puteri Novani
Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler
description This study aims to create a system that can monitor gas cylinders where this device consists of two systems, the first is a system to measure the weight of 3kg LPG gas cylinders to find the remaining gas which will then be displayed on the LCD, and the second the system gives a notification (alarm) if there is a gas leak via SMS. This system consists of Arduino UNO Microcontroller components, Load cell Sensor, MQ-6 Sensor, and SIM800L GSM Module. For overall system testing, the load cell sensor system can display a percentage of the weight value obtained an error rate of 0%, this indicates that the formula used in the program runs according to what is desired. In the MQ-6 sensor system can make the buzzer on at a value >= 700 ppm, the results of the buzzer can live when the detected gas value >= 700 ppm, this is as desired. In the sim800L gsm module system can send leak notifications, the results obtained that the module can send SMS notifications. And the system turns on the buzzer when the LPG gas has reached the minimum limit, the results obtained by the buzzer will sound when the remaining gas value <= 16%. Based on tests conducted on this system the system can measure the desired weight of the cylinder to look for the remaining gas in the form of a percentage and detect a gas leak and then send an SMS notification.
format article
author Anisha Fadia Haya
Werman Kasoep
Nefy Puteri Novani
author_facet Anisha Fadia Haya
Werman Kasoep
Nefy Puteri Novani
author_sort Anisha Fadia Haya
title Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler
title_short Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler
title_full Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler
title_fullStr Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler
title_full_unstemmed Rancang Bangun Smart Case Sistem Monitoring Tabung Gas Elpiji Berbasis Mikrokontroler
title_sort rancang bangun smart case sistem monitoring tabung gas elpiji berbasis mikrokontroler
publisher Universitas Andalas
publishDate 2020
url https://doaj.org/article/3209a01974f642f484ebd8bddf8411ea
work_keys_str_mv AT anishafadiahaya rancangbangunsmartcasesistemmonitoringtabunggaselpijiberbasismikrokontroler
AT wermankasoep rancangbangunsmartcasesistemmonitoringtabunggaselpijiberbasismikrokontroler
AT nefyputerinovani rancangbangunsmartcasesistemmonitoringtabunggaselpijiberbasismikrokontroler
_version_ 1718417785338462208